SPM003-HANDHELD 25BAR PNEUMATIC PRESSURE TEST PUMP
|
|
Portable Pressure Test pumps (Patent number: 200920108327.5) are made up of top quality imported stainlesssteel andaluminum materials.They adopt advanced Germany sealing technologyand sealing components, easy to use.
Theyare ideal instruments to calibrate pressure gauges,pressure transmitters,pressure sensors and other pressure instruments.
Portable only1.5kg, High resolution , Laboratory/Field available.
Pressure Range:(-0.95-25)bar (-0.095-2.5)Mpa, (-14-375)psi... |
Pressure Instruments
|
|
|
|
SPM002-HANDHELD 4BAR LOW PRESSURE TEST PUMP
|
|
Portable Pressure Test pumps (Patent number: 200920108327.5) are made up of top quality imported stainlesssteel andaluminum materials.They adopt advanced Germany sealing technologyand sealing components, easy to use.
Theyare ideal instruments to calibrate pressure gauges,pressure transmitters,pressure sensors and other pressure instruments.
Portable only1.5kg, High resolution , Laboratory/Field available.
Pressure Range:(-0.95-4)bar (-0.095-0.4)Mpa; (-14-60)psi Adjustment... |
Pressure Instruments
|
|
|
|
SPM001-PORTABLE HANDHELD 0.4BAR LOW PRESSURE TEST PUMP
|
|
Portable Pressure Test pumps (Patent number: 200920108327.5) are made up of top quality imported stainlesssteel andaluminum materials.They adopt advanced Germany sealing technologyand sealing components, easy to use.
Theyare ideal instruments to calibrate pressure gauges,pressure transmitters,pressure sensors and other pressure instruments.
Portable only1.5kg, High resolution , Laboratory/Field available.
Pressure Range:(-0.4-0.4)bar;(-6-6)psi;(-40-40)kpa Adjustment Resolution:0.001mbar... |
Pressure Instruments
|
|
|
|
SEW0086D-AL-39C Adaptor
|
|
● Solid copper spade lug. Designed to fasten housing or screws for measurement. Fully insulated, axial mount 4mm banana jack. Designed especially for terminal posts, The Y-shaped tip accepts housings or screws that have a diameter of 6.5mm or less. |
Test-leads
|
|
|
|
SEW0084-ELECTRICITY TEST BOX
|
|
FEATURES
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.
SPECIFICATIONS
RCD Testing
Range
10mA @ 150ms 30mA @ 150ms 150mA... |
Test Box/Trainers
|
|
|
|
SEW0123P03-ST2000 3803--5/25A 60-300V POWER FACTOR METER
|
|
FEATURES
Principle : Phase angle sensing transducer
Meets CE
Rated Accuracy : ±3% phase angle
Scale :Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 LagPower Angle: Lead 90° – 0° – 90° Lag
Effective Power Factor Measuring Range :Lead 0.5 – 1.0 – 0.5 Lag
Scale Length : Approx. 135mm(5-3/8”)
Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz
|
Panel meters
|
|
|
|
SEW0123P02-ST2000 3802--1/5A 60-300V POWER FACTOR METER
|
|
FEATURES
Principle : Phase angle sensing transducer
Meets CE
Rated Accuracy : ±3% phase angle
Scale :Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 LagPower Angle: Lead 90° – 0° – 90° Lag
Effective Power Factor Measuring Range :Lead 0.5 – 1.0 – 0.5 Lag
Scale Length : Approx. 135mm(5-3/8”)
Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz
|
Panel meters
|
|
|
|
SEW0123P01-ST2000 3801--0.2/1A 120V POWER FACTOR METER Portable Power Factor Meter (Taut Band movement)
|
|
FEATURES
Principle : Phase angle sensing transducer
Meets CE
Rated Accuracy : ±3% phase angle
Scale :Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 LagPower Angle: Lead 90° – 0° – 90° Lag
Effective Power Factor Measuring Range :Lead 0.5 – 1.0 – 0.5 Lag
Scale Length : Approx. 135mm(5-3/8”)
Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz
|
Panel meters
|
|
|
|
SEW0123F03-ST2000 1703--0-500HZ 120/240V FREQUENCY METER (NOT INCLUDE CABLE/TESTLEADS
|
|
FEATURES
Principle : Frequency sensing transducer
Meets CE
Accuracy :±0.5% of full scale value on 45 to 65 Hz range±0.5% of full scale value on 0 to 100Hz range±0.5% of full scale value on 0 to 500Hz range
Scale Length : Approx. 135mm (5-3/8”)
Case Material : Bakelite with glass window
|
Panel meters
|
|
|
|
SEW0123F02-ST2000 1702--0-100HZ 120/240V FREQUENCY METER (NOT INCLUDE CABLE/TESTLEADS
|
|
FEATURES
Principle : Frequency sensing transducer
Meets CE
Accuracy :±0.5% of full scale value on 45 to 65 Hz range±0.5% of full scale value on 0 to 100Hz range±0.5% of full scale value on 0 to 500Hz range
Scale Length : Approx. 135mm (5-3/8”)
Case Material : Bakelite with glass window
|
Panel meters
|
|
|
|
SEW0123F01-ST2000 1701--45-65HZ 120/240V FREQUENCY METER (NOT INCLUDE CABLE/TESTLEADS
|
|
FEATURES
Principle : Frequency sensing transducer
Meets CE
Accuracy :±0.5% of full scale value on 45 to 65 Hz range±0.5% of full scale value on 0 to 100Hz range±0.5% of full scale value on 0 to 500Hz range
Scale Length : Approx. 135mm (5-3/8”)
Case Material : Bakelite with glass window
|
Panel meters
|
|
|
|
SEW0123B05-ST2000 2104--5/25A 120/240V WATTMETER NOT INCLUDE CABLE/TESTLEADS
|
|
FEATURES
Principle : Electrodynamometer type
Meets CE
Accuracy : ±0.5% of full scale
Scale Length : Approx. 135mm(5-3/8”)
Scale Divisions : 120
Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)
|
Panel meters
|
|
|
|
SEW0123B04-ST2000 2103-2/10A 120/240V WATTMETER NOT INCLUDE CABLE/TESTLEADS
|
|
FEATURES
Principle : Electrodynamometer type
Meets CE
Accuracy : ±0.5% of full scale
Scale Length : Approx. 135mm(5-3/8”)
Scale Divisions : 120
Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)
|
Panel meters
|
|
|
|
SEW0123B03-ST2000 2101-0.2/1A 120/240V WATTMETER NOT INCLUDE CABLE/TESTLEADS
|
|
FEATURES
Principle : Electrodynamometer type
Meets CE
Accuracy : ±0.5% of full scale
Scale Length : Approx. 135mm(5-3/8”)
Scale Divisions : 120
Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)
|
Panel meters
|
|
|
|
SEW0123B01-ST2000 2102 1/5A 120/240V PORTABLE WATTMETER NOT INCLUDE CABLE/TESTLEADS
|
|
FEATURES
Principle : Electrodynamometer type
Meets CE
Accuracy : ±0.5% of full scale
Scale Length : Approx. 135mm(5-3/8”)
Scale Divisions : 120
Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)
|
Panel meters
|
|
|
|
SEW0123B-ST2000(2119) PORTABLE WATTMMETER NOT INCLUDE CABLE 1/5A 240/480V
|
|
1/5A240/480V
FEATURES
Principle : Electrodynamometer type
Meets CE
Accuracy : ±0.5% of full scale
Scale Length : Approx. 135mm(5-3/8”)
Scale Divisions : 120
Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)
|
Panel meters
|
|
|
|
SEW0028C DC30KV AC20KV HIGH VOLTAGE PROBE (HV PROBE) DC30KV/AC20KV FOR SCOPE/OSCILLOSCOPES- 20S
|
|
FEATURES
Measures both AC and DC voltages with oscilloscopes.
Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.
Lightweight and rugged.
2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
SPECIFICATIONS
Input impedance
500 MΩ
Attenuation ratio
1000 : 1
Accuracy
DCV (0 ~ 20kV) ± 1%DCV (20kV ~ 30kV) ± 2%ACV (0 ~ 20kV) typically ± 5% at 50/60... |
Current probes (AC/DC)
|
|
|
|
SEW0028B DC30KV AC20KV HIGH VOLTAGE PROBE (HV PROBE) DC30KV/AC20KV FOR DMM - 20
|
|
FEATURES
Measures both AC and DC voltages with digital multitester.
Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.
Lightweight and rugged.
2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
SPECIFICATIONS
Input impedance
500 MΩ
Attenuation ratio
1000 : 1
Accuracy
DCV (0 ~ 20kV) ± 1%DCV (20kV ~ 30kV) ± 2%ACV (0 ~ 20kV) typically ± 5% at 50/60... |
Current probes (AC/DC)
|
|
|
|
SEW0028 DC40KV AC28V HIGH VOLTAGE PROBE (HV PROBE) DC40KV/AC28KV FOR DMM - 28
|
|
FEATURES
Measures both AC and DC voltages with digital multitester.
Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.
Lightweight and rugged.
2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
SPECIFICATIONS
Input impedance
1000 MΩ
Attenuation ratio
1000 : 1
Accuracy
DCV (0 ~ 20kV) ± 1%DCV (20kV ~ 40kV) ± 2%ACV (0 ~ 28kV) typically ± 5% at 50/60... |
Current probes (AC/DC)
|
|
|
|
SEW0019-PD40AMV2 DC40KV HIGH VOLTAGE DETECTOR WITH BUILT-IN DCV INDICATOR (PD-40AM)
|
|
FEATURES
Measures positive polarity DC voltages up to 40kV.
Lightweight and rugged.
2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.
SPECIFICATIONS
Input impedance
600 MΩ
Attenuation ratio
40000 : 1
Accuracy
DCV (0 ~ 20kV) ± 2%DCV (20kV ~ 40kV) ± 3%
Max. working voltage
DC 40kV
Operating... |
Current probes (AC/DC)
|
|