• Filter
  Name SKU Description Category
Fluke i400 AC Current Clamp with Banana Plug Connections Companion to your DMM to measure up to 400 A AC 1mA/Amp output guarantees easy reading on you meter Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating Specially designed to offer maximum utility in a very compact shape Take accurate current readings without breaking the circuit Soft non-slippery overmold handle prevents from accidental touching live wiring Max. conductor Ø 32 mm Current Clamps
Fluke i310s Current Clamp Current Ranges: 30 A and 300 A ACRMS or DCMeasuring Ranges: ±45 A and 450 A Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A) Resolution: ±50 mA (40 A) to ±100 mA (400 A) Load Impedance: > 10 k Ohms and £ 100 pF Frequency Range (small signal): DC to 20 kHz (- 3 dB) Phase Shift below 1 kHz, < 2 degrees Temperature Coefficient: ±0.1% of reading / ±C Power Supply: 9 V Alkaline Current Clamps
Fluke i3000 Flex-36 AC Current Clamp, 915mm (36in.) Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm (7 in.) CAT III 600V safety rating Current Clamps
Fluke i3000s Flex 24 AC Current Clamp 610mm (24in.) Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm (7 in.) CAT III 600V safety rating Current Clamps
Fluke i3000 Flex-4PK AC Current Probe, 4 Pack Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm (7 in.) CAT III 600V safety rating Current Clamps
Fluke i30 AC/DC Current Clamp The i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC current The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement Current Clamps
Fluke i3000s AC Current Clamp An optional accessory for use with Fluke DMMs, PowerMeters and ScopeMeter test tools Measures ac current from 1A to 2400A RMS continuous PM9081/001 BNC to banana adapter included Current Clamps
Fluke I2500-18 IFlex Flexible Current Probe - 18" Expands the measurement range to 2500A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access CAT IV 600 V, CAT III 1000 V 7.5 mm coil diameter allows measurement in tight spaces Ergonomic design allows easy operation with one hand 1.8 m (6 ft) cable Three-year warranty Current Clamps
Fluke I2500-10 IFlex Flexible Current Probe - 10" Expands the measurement range to 2500A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access CAT IV 600 V, CAT III 1000 V 7.5 mm coil diameter allows measurement in tight spaces Ergonomic design allows easy operation with one hand 1.8 m (6 ft) cable Three-year warranty Current Clamps
Fluke i200s AC Current Clamp Companion to your scopemeter, power quality meter or digital multimeter to measure up to 200 A AC Included adapter for DMM's Two ranges: 20 A & 200A, 10 or 100 mV/ Amp output Take accurate current readings without breaking the circuit Max. conductor Ø 20 mm CAT III 600V safety rating Current Clamps
Fluke i2000-Flex AC Flexible Current Clamp Three ranges: 20A, 200 A & 2000 A, 1 mV, 10 mV & 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm CAT III 600V safety rating Current Clamps
Fluke i200 Small AC Current Clamp Companion to a DMM to measure up to 200 A AC 1mA per Amp output guarantees easy reading on you meter Take accurate current readings without breaking the circuit Max. conductor Ø 20 mm CAT III 600V safety rating Current Clamps
Fluke i1010 Kit AC/DC Current Clamp and Carry Case Kit i1010 1-600A AC rms, 1-1000A DC Current Clamp Zippered vinyl carry case with moveable divider Current Clamps
Fluke i1010 AC/DC Current Clamp Battery-powered dual Hall-effect, clamp-on probe measures dc current from 1-1000A; ac current from 1-600A ac rms Measures ac and dc current down to 1 amp with specified accuracy and is useable to 0.5A Output is 1 mV per amp dc or ac Jaws accept conductor size of 1 X 750 MCM ( 30 mm/1.18 in. diameter) or 2 X 500 MCM (2 X 25 mm/.98 in.) AC and DC accuracy: ± (2.0% of reading + 0.5A) Current Clamps
Fluke i1000s AC Current Probe Current Range: 100mA to 1000 Arms Basic Accuracy 48Hz to 65Hz: 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output Bandwidth: 5Hz to 100kHz Working Voltage: 600V AC rms Maximum Conductor Size: 54 mm (2.13 inch) diameter Safety Rating: 600V rms. CAT III per IEC 1010-02-032 Current Clamps
Fluke i1000s AC Current Probe Current Range: 100mA to 1000 Arms Basic Accuracy 48Hz to 65Hz: 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output Bandwidth: 5Hz to 100kHz Working Voltage: 600V AC rms Maximum Conductor Size: 54 mm (2.13 inch) diameter Safety Rating: 600V rms. CAT III per IEC 1010-02-032 Current Clamps
Fluke 90i-610s 1A to 600A AC/DC Current Probe Current Range: 1 to 600 A DC or AC Peak Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A) Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A Frequency Range: 40 Hz to 400 Hz Working Voltage: 600 V AC rms Maximum Conductor Diameter: 34 mm (1.34 inch) Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V Current Clamps
Fluke 80i-110s AC/DC Current Clamp Current Range: 0.1 to 100A DC or 0.1 to 70A AC Basic Accuracy (DC to 1kHz): 100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA 10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA40A to 80A +/- 12% of reading + 50mA80 to 100A +/- 15% of reading Output Signal: 10A range: 100mV/A | 100A range: 10mV/A Bandwidth: 1Hz to 20kHz Working Voltage: 600V AC rms Maximum Conductor Size: 1.8 mm (.46 inch) diameter Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II,... Current Clamps
Fluke FOS-850/1300 Fiber Optic Light Source A variety of light sources allow you to test different cable lengths. One year warranty Fiber Optics
Fluke FOS-850 Fiber Optic Light Source A variety of light sources allow you to test different cable lengths. One year warranty Fiber Optics