Fluke 3584R Split-Core Current Transformers
|
|
Current range: 0.1 – 40A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamps
|
|
|
|
Fluke 3583R Split-Core Current Transformers
|
|
Current range: 0.01 – 10A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamps
|
|
|
|
Fluke 3212-PR-TF 5000A Flex Thin Flex Current Probe, 4 Feet Long For the Fluke 1750 Power Recorder
|
|
The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamps
|
|
|
|
Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe, 2 Feet Long For the Fluke 1750 Power Recorder
|
|
The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamps
|
|
|
|
Fluke 3300 Clamp-on Current Transformer
|
|
Current range: 10-3000A
Accuracy: 2% RDG +/- 0.05% FS
Frequency response: 5 kHz
Jaw opening: 3.5 x 4.5” dia. (9 x 11 cm)
|
Current Clamps
|
|
|
|
Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe For the Fluke 1750 Power Recorder
|
|
The Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3210PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamps
|
|
|
|
Fluke 3120R Clamp-on Current Transformer
|
|
Current range: 0.05-200A
Accuracy: 1% RDG +/- 0.3% FS
Frequency response: 5 kHz
Jaw opening: .78” dia. (2 cm)
|
Current Clamps
|
|
|
|
Fluke 3112RPM Flexi-CT™ Flexible Current Transformer
|
|
Current range: 2-100
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 7 kHz
Length: 48” (1.2 cm)
|
Current Clamps
|
|
|
|
Fluke 3100R Clamp-on Current Transformer
|
|
Current range: 1-1000A
Accuracy: 1% RDG +/- 0.05% FS
Frequency response: 5 kHz
Jaw opening: 2" dia. (5 cm)
|
Current Clamps
|
|
|
|
Fluke 140S-PR Clamp-on Current Transformer
|
|
Operates with the Fluke 1750 Power Recorder
It supplies accurate nonintrusive measurement of ac current
The probe has a current range from 0.05 A to 40 A
The frequency range is 40 Hz to 5 kHz
The clamp is approved for CAT III 600 V
|
Current Clamps
|
|
|
|
Fluke i800 AC Current Clamp Probe
|
|
Measures AC current from 100mA to 800 A rms
30 Hz to 10 kHz frequency range
CAT III 600 V rating
Accepts up to 54 mm (2.1 in) diameter conductor size
1000:1 conversion factor for easy calculation
Rugged positive action design
|
Current Clamps
|
|
|
|
Fluke i6000s Flex-36 AC Current Clamp (36in.)
|
|
The i6000sflex is an AC current probe utilizing the Rogowski principle
It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers
The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas
Current Ranges: 60A/600A/6000A AC RMS
Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A
Frequency Range: 10 Hz to 50 kHz (- 3 dB)
Load Impedance: 100 kOhm minimum
Accuracy (at +25°C): ±1%... |
Current Clamps
|
|
|
|
Fluke i6000s Flex-24 AC Current Clamp (24in.)
|
|
The i6000sflex is an AC current probe utilizing the Rogowski principle
It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers
The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas
Current Ranges: 60A/600A/6000A AC RMS
Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A
Frequency Range: 10 Hz to 50 kHz (- 3 dB)
Load Impedance: 100 kOhm minimum
Accuracy (at +25°C): ±1%... |
Current Clamps
|
|
|
|
Fluke i5sPQ3 AC 5A Current Clamp (3 Pack)
|
|
Low level current clamp measures up to 5 A ac
Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches)
Take accurate readings without breakings the circuit
CAT III 600 V (For insulated conductors only)
|
Current Clamps
|
|
|
|
Fluke i5s AC Current Clamp
|
|
Expand the use of your Fluke 430 series power quality tool with this 5A ac current clamp
Specially configured to provide low current accuracy while taking measurements on secondary current transformers
Low level current clamp measures up to 5A ac
Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches)
Take accurate readings without breakings the circuit
CAT III 600 V (For insulated conductors only)
|
Current Clamps
|
|
|
|
Fluke i430-Flexi-TF-4PK 6000 A Flexible AC Current Probe
|
|
Current Range: 6000 A AC
Frequency Range: 10 Hz to 7 kHz (-3 dB)
Accuracy: +/- 1% of reading (@25 C, 50 Hz)
|
Current Clamps
|
|
|
|
Fluke i430-Flexi-TF 6000 A Flexible AC Current Probe
|
|
Current Range: 6000 A AC
Frequency Range: 10 Hz to 7 kHz (-3 dB)
Accuracy: +/- 1% of reading (@25 C, 50 Hz)
|
Current Clamps
|
|
|
|
Fluke i410-Kit AC/DC Current Clamp and Carry Case Kit
|
|
i410 1-400A AC rms, 1-400A DC Current Clamp
Zippered vinyl carry case with moveable divider
|
Current Clamps
|
|
|
|
Fluke i410 AC/DC Current Clamp
|
|
Battery-powered Hall-effect probe measures 1A to 400 A
1mV/Amp output guarantees easy reading on your meter
Take accurate current readings without breaking the circuit
Maximum conductor Ø 32 mm
CAT III 600 V safety rating
Also available with softcase for DMM and clamp (i410 kit)
One year warranty
|
Current Clamps
|
|
|
|
Fluke i400s 400 A Current Clamp
|
|
Companion to your scope or power quality meter to measure up to 400 A AC.
Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating.
Specially designed to offer maximum utility in a compact shape.
Take accurate current readings without breaking the circuit.
Soft non-slippery overmold handle.
Optional PM9081/001 BNC/Banana adapter for DMM's.
Two ranges: 40 A & 400 A, 10 & 1 mV/Amp output.
Max. conductor Ø 32 mm.
|
Current Clamps
|
|