• Filter
  Name SKU Description Category
SPM010-2500 BAR PORTABLE DESKTOP ULTRAHIGH HYDRAULIC PRESSURE TEST PUMP   Desk-top Pressure Calibration Pumps (Patent number: 200920108327.5) are made up of top quality imported stainless steel and aluminum materials. They adop advanced Germany sealing technology and sealing components, easy to use . They are ideal instruments to calibrate pressure gauges, pressure transmitters, pressure sensors and other pressure instruments. Easy to use,maintenance-free. fine adjustment avaliable. Laboratory available. Pressure Range:(-0.85-2500)bar,(-0.085-250)Mpa,... Pressure Instruments
SPM011-600 BAR PORTABLE DESKTOP WATER PRESSURE CALIBRATION PUMP   Desk-top Pressure Calibration Pumps (Patent number: 200920108327.5) are made up of top quality imported stainless steel and aluminum materials. They adop advanced Germany sealing technology and sealing components, easy to use . They are ideal instruments to calibrate pressure gauges, pressure transmitters, pressure sensors and other pressure instruments. Easy control by spiral lisfting gear. Pure water as Medium,oil-forbidden. Water drop by special Vent valve, no contamination. precise... Pressure Instruments
SPM012-700 BAR PORTABLE DESKTOP HYDRAULIC PRESSURE CALIBRATION PUMP   Desk-top Pressure Calibration Pumps (Patent number: 200920108327.5) are made up of top quality imported stainless steel and aluminum materials. They adop advanced Germany sealing technology and sealing components, easy to use . They are ideal instruments to calibrate pressure gauges, pressure transmitters, pressure sensors and other pressure instruments. Spiral lifting gear pressure, easy control and convenient, Laboratory available, Pressure range up to 250Mpa is customized. Pressure... Pressure Instruments
SEW0086D-AL-39C Adaptor ● Solid copper spade lug. Designed to fasten housing or    screws for measurement.    Fully insulated, axial mount 4mm banana jack.     Designed especially for terminal posts,    The Y-shaped tip accepts housings or screws that have a    diameter of 6.5mm or less. Test-leads
SEW0084-ELECTRICITY TEST BOX FEATURES ● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.     SPECIFICATIONS RCD Testing Range 10mA @ 150ms 30mA @ 150ms 150mA... Test Box/Trainers
SEW0123B-ST2000(2119) PORTABLE WATTMMETER NOT INCLUDE CABLE 1/5A 240/480V 1/5A240/480V FEATURES Principle : Electrodynamometer type Meets CE Accuracy : ±0.5% of full scale Scale Length : Approx. 135mm(5-3/8”) Scale Divisions : 120 Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)   Panel meters
SEW0123B01-ST2000 2102 1/5A 120/240V PORTABLE WATTMETER NOT INCLUDE CABLE/TESTLEADS   FEATURES Principle : Electrodynamometer type Meets CE Accuracy : ±0.5% of full scale Scale Length : Approx. 135mm(5-3/8”) Scale Divisions : 120 Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)   Panel meters
SEW0123B03-ST2000 2101-0.2/1A 120/240V WATTMETER NOT INCLUDE CABLE/TESTLEADS   FEATURES Principle : Electrodynamometer type Meets CE Accuracy : ±0.5% of full scale Scale Length : Approx. 135mm(5-3/8”) Scale Divisions : 120 Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)   Panel meters
SEW0123B04-ST2000 2103-2/10A 120/240V WATTMETER NOT INCLUDE CABLE/TESTLEADS   FEATURES Principle : Electrodynamometer type Meets CE Accuracy : ±0.5% of full scale Scale Length : Approx. 135mm(5-3/8”) Scale Divisions : 120 Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)   Panel meters
SEW0123B05-ST2000 2104--5/25A 120/240V WATTMETER NOT INCLUDE CABLE/TESTLEADS   FEATURES Principle : Electrodynamometer type Meets CE Accuracy : ±0.5% of full scale Scale Length : Approx. 135mm(5-3/8”) Scale Divisions : 120 Frequency Ranges :AC 25 to 1000Hz (COSØ=1.0) (suitable for DC)AC 25 to 500Hz (COSØ=0.2)   Panel meters
SEW0123F01-ST2000 1701--45-65HZ 120/240V FREQUENCY METER (NOT INCLUDE CABLE/TESTLEADS FEATURES Principle : Frequency sensing transducer Meets CE Accuracy :±0.5% of full scale value on 45 to 65 Hz range±0.5% of full scale value on 0 to 100Hz range±0.5% of full scale value on 0 to 500Hz range Scale Length : Approx. 135mm (5-3/8”) Case Material : Bakelite with glass window Panel meters
SEW0123F02-ST2000 1702--0-100HZ 120/240V FREQUENCY METER (NOT INCLUDE CABLE/TESTLEADS FEATURES Principle : Frequency sensing transducer Meets CE Accuracy :±0.5% of full scale value on 45 to 65 Hz range±0.5% of full scale value on 0 to 100Hz range±0.5% of full scale value on 0 to 500Hz range Scale Length : Approx. 135mm (5-3/8”) Case Material : Bakelite with glass window Panel meters
SEW0123F03-ST2000 1703--0-500HZ 120/240V FREQUENCY METER (NOT INCLUDE CABLE/TESTLEADS FEATURES Principle : Frequency sensing transducer Meets CE Accuracy :±0.5% of full scale value on 45 to 65 Hz range±0.5% of full scale value on 0 to 100Hz range±0.5% of full scale value on 0 to 500Hz range Scale Length : Approx. 135mm (5-3/8”) Case Material : Bakelite with glass window Panel meters
SEW0123P01-ST2000 3801--0.2/1A 120V POWER FACTOR METER Portable Power Factor Meter (Taut Band movement) FEATURES Principle : Phase angle sensing transducer Meets CE Rated Accuracy : ±3% phase angle Scale :Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 LagPower Angle: Lead 90° – 0° – 90° Lag Effective Power Factor Measuring Range :Lead 0.5 – 1.0 – 0.5 Lag Scale Length : Approx. 135mm(5-3/8”) Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz Panel meters
SEW0123P02-ST2000 3802--1/5A 60-300V POWER FACTOR METER FEATURES Principle : Phase angle sensing transducer Meets CE Rated Accuracy : ±3% phase angle Scale :Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 LagPower Angle: Lead 90° – 0° – 90° Lag Effective Power Factor Measuring Range :Lead 0.5 – 1.0 – 0.5 Lag Scale Length : Approx. 135mm(5-3/8”) Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz Panel meters
SEW0123P03-ST2000 3803--5/25A 60-300V POWER FACTOR METER FEATURES Principle : Phase angle sensing transducer Meets CE Rated Accuracy : ±3% phase angle Scale :Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 LagPower Angle: Lead 90° – 0° – 90° Lag Effective Power Factor Measuring Range :Lead 0.5 – 1.0 – 0.5 Lag Scale Length : Approx. 135mm(5-3/8”) Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz Panel meters
SEW0019-PD40AMV2 DC40KV HIGH VOLTAGE DETECTOR WITH BUILT-IN DCV INDICATOR (PD-40AM) FEATURES Measures positive polarity DC voltages up to 40kV. Lightweight and rugged. 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode. Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.   SPECIFICATIONS Input impedance 600 MΩ Attenuation ratio 40000 : 1 Accuracy DCV (0 ~ 20kV) ± 2%DCV (20kV ~ 40kV) ± 3% Max. working voltage DC 40kV Operating... Current probes (AC/DC)
SEW0028 DC40KV AC28V HIGH VOLTAGE PROBE (HV PROBE) DC40KV/AC28KV FOR DMM - 28 FEATURES Measures both AC and DC voltages with digital multitester. Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories. Lightweight and rugged. 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.   SPECIFICATIONS Input impedance 1000 MΩ Attenuation ratio 1000 : 1 Accuracy DCV (0 ~ 20kV) ± 1%DCV (20kV ~ 40kV) ± 2%ACV (0 ~ 28kV) typically ± 5% at 50/60... Current probes (AC/DC)
SEW0028B DC30KV AC20KV HIGH VOLTAGE PROBE (HV PROBE) DC30KV/AC20KV FOR DMM - 20   FEATURES Measures both AC and DC voltages with digital multitester. Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories. Lightweight and rugged. 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.   SPECIFICATIONS Input impedance 500 MΩ Attenuation ratio 1000 : 1 Accuracy DCV (0 ~ 20kV) ± 1%DCV (20kV ~ 30kV) ± 2%ACV (0 ~ 20kV) typically ± 5% at 50/60... Current probes (AC/DC)
SEW0028C DC30KV AC20KV HIGH VOLTAGE PROBE (HV PROBE) DC30KV/AC20KV FOR SCOPE/OSCILLOSCOPES- 20S FEATURES Measures both AC and DC voltages with oscilloscopes. Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories. Lightweight and rugged. 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.   SPECIFICATIONS Input impedance 500 MΩ Attenuation ratio 1000 : 1 Accuracy DCV (0 ~ 20kV) ± 1%DCV (20kV ~ 30kV) ± 2%ACV (0 ~ 20kV) typically ± 5% at 50/60... Current probes (AC/DC)