Fluke i800 AC Current Clamp Probe
|
|
Measures AC current from 100mA to 800 A rms
30 Hz to 10 kHz frequency range
CAT III 600 V rating
Accepts up to 54 mm (2.1 in) diameter conductor size
1000:1 conversion factor for easy calculation
Rugged positive action design
|
Current Clamps
|
|
|
|
Fluke 140S-PR Clamp-on Current Transformer
|
|
Operates with the Fluke 1750 Power Recorder
It supplies accurate nonintrusive measurement of ac current
The probe has a current range from 0.05 A to 40 A
The frequency range is 40 Hz to 5 kHz
The clamp is approved for CAT III 600 V
|
Current Clamps
|
|
|
|
Fluke 3100R Clamp-on Current Transformer
|
|
Current range: 1-1000A
Accuracy: 1% RDG +/- 0.05% FS
Frequency response: 5 kHz
Jaw opening: 2" dia. (5 cm)
|
Current Clamps
|
|
|
|
Fluke 3112RPM Flexi-CT™ Flexible Current Transformer
|
|
Current range: 2-100
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 7 kHz
Length: 48” (1.2 cm)
|
Current Clamps
|
|
|
|
Fluke 3120R Clamp-on Current Transformer
|
|
Current range: 0.05-200A
Accuracy: 1% RDG +/- 0.3% FS
Frequency response: 5 kHz
Jaw opening: .78” dia. (2 cm)
|
Current Clamps
|
|
|
|
Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe For the Fluke 1750 Power Recorder
|
|
The Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3210PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamps
|
|
|
|
Fluke 3300 Clamp-on Current Transformer
|
|
Current range: 10-3000A
Accuracy: 2% RDG +/- 0.05% FS
Frequency response: 5 kHz
Jaw opening: 3.5 x 4.5” dia. (9 x 11 cm)
|
Current Clamps
|
|
|
|
Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe, 2 Feet Long For the Fluke 1750 Power Recorder
|
|
The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamps
|
|
|
|
Fluke 3212-PR-TF 5000A Flex Thin Flex Current Probe, 4 Feet Long For the Fluke 1750 Power Recorder
|
|
The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. |
Current Clamps
|
|
|
|
Fluke 3583R Split-Core Current Transformers
|
|
Current range: 0.01 – 10A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamps
|
|
|
|
Fluke 3584R Split-Core Current Transformers
|
|
Current range: 0.1 – 40A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamps
|
|
|
|
Fluke 3585R Split-Core Current Transformers
|
|
Current range: 0.5 – 1-0A
Accuracy: 1% RDG +/- 0.5% FS
Frequency response: 5 kHz
Length: 7/16” (1 cm)
|
Current Clamps
|
|
|
|
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer
|
|
Measuring Range selectable per software:0.01A to 1A0.1A to 10A
Peak current for sinusoidal currents:3.7A to 37A
Intrinsic error: 0.5%
Frequency Range: 40Hz to 10kHz
Operating Voltage: 300V CAT IV
Phase Error: 0.5°
Jaw Opening: <15mm diameter or 15x17mm bus bars
Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamps
|
|
|
|
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer
|
|
Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A
Peak current for sinusoidal currents74 A 300 A
Intrinsic error 0.5%
Frequency Range 40 Hz to 10 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamps
|
|
|
|
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer
|
|
Measuring Range selectable per software 1 A to 100 A 5 A to 500 A
Peak current for sinusoidal currents 240 A 1350 A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening 45 cm length
2 m cable
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamps
|
|
|
|
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
1A to 100A
5A to 500A
Peak current for sinusoidal currents:
240A
1350A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamps
|
|
|
|
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
2A to 200A
10A to 1000A
Peak current for sinusoidal currents:
480A
2700A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 600 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamps
|
|
|
|
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
30A to 3000A
60A to 6000A
Peak current for sinusoidal currents:
10kA
19kA
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamps
|
|
|
|
Fluke FOM Fiber Optic Meter
|
|
The compact FOM plugs into your DMM and makes testing in tight spaces easy
A variety of light sources (FOS 850, FOS 1300, and FOS 850/1300) and patch cords (ST to ST, ST to FC, ST to SC, ST to SMA) let you get just what you need for testing different cable types and lengths
Highly accurate readings mean less work, less repeated testing
Input connector: fixed ST
Battery life: 16 hours minimum, 9V alkaline
LED low battery indicator
Operating temperature: 0°C to +40°C (32°F to... |
Fiber Optics
|
|
|
|
Fluke FOS-850 Fiber Optic Light Source
|
|
A variety of light sources allow you to test different cable lengths.
One year warranty
|
Fiber Optics
|
|