Products

  • Filter
  Name SKU Description Category
TST0064-410-2 Air velocity meter with rh,temp KKI TST0064 is designed for the measurement of air flow velocity, temperature and humidity. This Germany own patented humidity sensor guarantees reliable measurement results. Thanks to the integrated measurement with the 40 mm vane   Airflow meters
TST0063-410-1 Air velocity meter (Germany) KKI TST0063 measures air speed and temperature. It is ideal for quick spot checks at air outlets on account of its integrated measurement with the 40mm vane. Timed mean calculation is possible. In addition to air speed and temperature. Airflow meters
TST0066-417 100mm large vane airflow meter Direction of flow recognition Temperature, flow and volume flow measurement Multi-point and timed mean calculation Max/min values Hold button to freeze readings   Airflow meters
TST0061-405 Economical anemometer Volume flow calculation up to 99,990 m3/h Temperature measurement Ideal for measurements in ducts   Airflow meters
TST0065-416 Telescopic vane anemometer ( From Germany) Multi-point and timed mean calculations Max-Min values make comparisons fast and easy "Hold" button freezes readings Display light Auto-Off function Includes: 0.6~40m/s Airflow meters
TES2100-1381 CONDUCTIVITY,RESISTIVITY,SALINITY,TEMP, & PH/ORP METER pH, mV, Conductivity, TDS, Resistivity, Salinity, Concentration and Temperature measurement functions. 0.001pH, 0.1mV, 0.001µS/cm, 0.001mg/L and 0.1°C / °F Resolution. Programmable Temperature Coefficient for conductivity measurement. Auto / Manual Temperature Compensation for pH and conductivity measurement. Practical Salinity in the Range of 0 to 42.0, in accordance with UNESCO data measurement. Dual display with temperature Simultaneously. Easy & Fast to operate. Ideal for... Water testers
TEN930B-TM-82NV2 DUAL INPUT DIGITAL K TYPE THERMOMETER W MAX/MIN VALUE - Dual LCD 5-digit display.- Single input (TEN930A), dual input (TEN930B).- Auto power off with disable function (15 minutes).- Max/Min/Avg/Hold function keys.- °C/°F switchable.- REL, OFFSET, T1-T2 (TEN930B) . Thermometers
TEN930A-TM-80NV2 DIGITAL K TYPE THERMOMETER W MAX/MIN VALUE - Dual LCD 5-digit display.- Single input (TEN930A), dual input (TEN930B).- Auto power off with disable function (15 minutes).- Max/Min/Avg/Hold function keys.- °C/°F switchable.- REL, OFFSET, T1-T2 (TEN930B) . Thermometers
TEN930-YF-160A-V2 ECONOMICAL DIGITAL K TYPE THERMOMETER Product Description - 3 1/2 Digits LCD maximum reading of 2000- ºC/ºF selectable- Type "K" thermocouple- Switchable resolution 0.1º / 1.0º- Data hold / Offset setting Thermometers
Thermometer strips thermometer strips are self-adhesive foils with temperature sensitive elements for temperature control and monitoring compressors, for example. +37 to +280 °C Temperature strips in quantities of more than 5000 are available on rolls Irreversible change in colour within 2 seconds Practical thermometer strips booklet with 10 strips Thermometers
TEN011-400A-AC/DC Current Transducer   Product Description CAT III 600V AC/DC current ranges 40A and 400A. Maximum conductor size 30mm. Low battery indication. Clamp meters
TEN010-TM-1017V3 400A TRUE-RMS AC POWER CLAMP METER + PHASE ROTATION CAT III 600V Maximum conductor size 30mm. Display counts: 4000. Measures: ACV, DCV, ACA. Measures Phase Sequence. Voltage/Current Harmonics to 25th with THD. W3ø, HV, HA, Phase SEQ, Audible continuity tests. Frequency to 400Hz. Active, Reactive, Apparent power/ energy on. Power Factor, cosø on Single/Three phase systems. Phase sequence. Clamp meters
TEN008-TM-1016V3 AC-HVAC VOLT/AMP/TEMP CLAMP METER WITH TEMPERATURE CAT III 600V 3-3/4 digit LCD Backlit Display, with Analog Bargraph. Display Counts: 4000. Auto Ranging. AC/DC current: 0.1µA to 4000µA. (using test leads). AC current: 0.01A to 400A (using jaw measurement). Ranges: ACV, ACA, DCV, DCA, Resistance, Continuity, Capacitance, and Temperature. Maximum conductor size 30mm. Continuity test below 40 ohms, buzzer will sound. Auto Power off. Double injection outer case. Clamp meters
TEN007-TM-2013V3 TRMS AC/DC CLAMP METER ACA DCA 660A CAT IV 600V, CAT III 1000V LCD backlit display, with maximum reading of 6600. AC voltage range: 0 to 750V. AC current range: 0 to 660A. DC voltage range: 0 to 1000V. DC Current: 0 to 660A. Resistance measurement to 66 megohms. Data Hold, Min/Max, Autoranging, DCA Zero. Test Ranges: ACV, ACA, Resistance, Frequency, Diode, Continuity. Work light. Auto Power Off. Double Injection outer case. Clamp meters
TEN006-TM-1018V3 AC/DC CLAMP METER (CUM AUTOMOTIVE CLAMP) CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, DCA, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case. Clamp meters
TEN005-TM-10124V3 ECONOMICAL AC CLAMP METER ACA400 ACV600 CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case. Clamp meters
TEN001-YF-8160 100A LEAKAGE AC CLAMP METER WITH NICKLE STEEL RING DISPLAY: - 3¾ digits LCD with maximum reading 4000. - Overload indication. - Low battery indication. FUNCTIONS: - Peak Hold. - Leakage Current Test. - Test ranges: ACV (600V), ACA (100A) , Ohm, Continuity. - Continuity test below 100Ohm will have buzzer sound. - Alternative for supply frequency. - With LPF (Low Pass Filter) function, 50/60Hz and wide frequency function (40~1KHz).- Maximum conductor size : 30mm.- Dimension : 250mm x 85mm x 35mm. Clamp meters
TES/PROVA Clamp meters All kinds of Taiwanese Clamp meters. Latest range.   Clamp meters
TST0459-270V2 DIGITAL COOKING OIL TESTER PLUS TEMPERATURE MEASUREMENT(FROM GERMANY) tester 270 supports you ideally in this measurement task, and offers further benefits: You ensure the quality of the oil and the satisfaction of your customers. You fulfil your measurement obligation without interrupting continuing operation. You are optimally supported in the application, e.g. by a traffic light function. Robust, safe and practical. This makes the cooking oil tester ideally suitable for use in a kitchen. You always work hygienically thanks... Cooking oil tester
TEN150-DIGITAL BASIC HANDHELD MILLIOHM METER 3-1/2 digit LCD display with maximum reading of 2000. Low battery indication. Zero adjustment: External zero adjustment control. Very low impedance measurement, four-wire type, one pair insulated clip. Wide measurement range 1 milliohm to 20k Ohm in six switchable steps. Fuse protection: 2 Amp/250Volt (5mm x 20mm), fast minimum interrupt ratings 1500A. Function keys: D-H switch lockup readings for LCD display. Dimensions: 160mm (L) x 100mm (W) x 52mm (D) Weight: 700g approx. Milli-Ohm meter/Micro-Ohm meters