By Brands

Sub Categories

Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable is most often two or more wires running side by side and bonded, twisted, or...
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
Performance characteristics: The box body and the lamp cap shell is made from high strength...
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
A refractometer is a laboratory or field device for the measurement of an index of refraction...
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
  Name SKU Description Category
DKK-TOA FMS-4 Fluoride Ion Monitor FMS-4 Simple measurement with just an ion electrode Enables continuous fluoride ion measurement of discharged industrial wastewater By adding ionic strength adjustment solution part of nonionic fluoride is measurable Automatic cleaning and calibration function ensures stable measurement Easy-to-use touch panel  Meas. range 0.1 - 10/0.2 - 20/1 - 100/10 - 1000 mg/L Simplified Fluoride Ion Monitor
DKK-TOA FBM-160(Field Installation Type) Simplified Fluoride Ion Monitor FBM-160(Field Installation Type) Outdoor field installation model Continuous monitoring of fluoride ion concentration by an ion electrode sensor with the alarm function (non-ionized fluoride is not detectable) Water-jet cleaning function available   Meas. range 0 - 99.9/999/9990 mg/L Simplified Fluoride Ion Monitor
DKK-TOA FBM-100A(Panel Type) Simplified Fluoride Ion Monitor FBM-100A(Panel Type) Compact DIN 96 size unit Quick and continuous detection of free fluoride ion concentration Monitors the effluent treatment processes and final effluent from semiconductor factories, etc. Meas. range 0 - 99.9/999/9990 mg/L Simplified Fluoride Ion Monitor
DKK-TOA NHMS-4 Simple measurement with just an ion electrode Enables continuous ammonium ion measurements in discharged industrial wastewater, river and water purification plants Automatic cleaning and calibration function ensures stable measurement Easy-to-use touch panel Low-concentration calibration function available Meas. range 0.05 - 5/0.1 - 10/1 - 100 mg/L Ammonium Ion Monitor
DKK-TOA CRM-1600 Automated intermittent monitoring unit; Spectrometric Method using 1,5-Diphenylcarbazide Stuck of the electromagnetic valve has been improved with rotating measurement cell Designed for discharged wastewater of plating factory, river water quality and related fields Meas. range 0 - 0.5/1.0 mg/L  (2-ranges) Hexavalent Chromium Monitor
DKK-TOA ODL-1600 Oil film is detected by measuring differences of the amount of laser reflectance of oil and water With improvements on light source scanning and signal processing, influences occurred in broad water surfaces such as fluctuation, waviness and suspended solids have been reduced effectively Contact-free and easy maintenance  Detectable range 0.3 - 3 m Oil Film Detector
DKK-TOA ODL-1610A Oil Film Detector (Long-Distance Model) ODL-1610A Enables oil film detection even if the surface of sample is 10m away from the detecting cell  Ideal for difficult conditions such as turbulent water and places where is difficult to setup near-water detectors Contact-free and easy maintenance  Detectable range 0.3 - 10 m Oil Film Detector
DKK-TOA OF-1600 Oil film is detected by measuring differences of the amount of LED reflectance of oil and water  Small and lightweight design Contact-free and easy maintenance Detectable range About 0.5 m Oil Film Detector
DKK-TOA SODL-1600 Oil Film Detector (Explosion-Proof Model) SODL-1600 Robust aluminum pressure resistance explosion-proof model Oil film is detected by measuring differences of the amount of laser reflectance of oil and water With improvements on light source scanning and signal processing, influences occurred in broad water surfaces such as fluctuation, waviness and suspended solids have been reduced effectively Contact-free and easy maintenance Detectable range 0.3 - 3 m Oil Film Detector
DKK-TOA FPM-377 PM2.5 Monitor FPM-377 Environment Ministry (JAPAN) Approval Beta ray attenuation method (mass concentration) Heater type dehumidifier VSC cyclone (USEPA approval) Outdoor type and indoor type available  Meas. range 0 - 500, 0 - 1000, 0 - 5000 μg/m3 Particulate Monitor
DKK-TOA FPM-222 US EPA Approval Beta ray attenuation method (mass concentration) Small and semi-permanent semiconductor detector is used to detect the Beta ray Easy calibration with the calibration film Meas. range 0 - 1000, 0 - 5000 μg/m3 (0 - 1, 0 - 5 mg/m3) Particulate Monitor
DKK-TOA GLN-314E Nitrogen Oxides Analyzer GLN-314E US EPA Approval Chemical luminescence method Alternating measurement of nitric monoxide (NO) and nitrogen oxides (NOx) ensures stable and continuous measurement of minute amounts of nitrogen oxides in the air Easy-to-use touch panel Meas. range 0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0, 0 - 2.0 ppm Nitrogen Oxides Analyzer
DKK-TOA GFS-312E Sulfur Dioxide Analyzer GFS-312E US EPA Approval Continuous measurement of SO2 by using Ultraviolet fluorescence method Improved optical system reduces the impact from interfering substances Easy-to-use touch panel Meas. range 0 - 0.05, 0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm Sulfur Dioxide Analyzer
DKK-TOA GUX-313E Ozone Analyzer GUX-313E US EPA Approval Continuous measurement of O3 concentration by using UV photometry method Easy-to-use touch panel Meas. range 0 - 0.1, 0 - 0.2, 0 - 0.5, 0 - 1.0 ppm Ozone Analyzer
DKK-TOA GFC-311E Carbon Monoxide Analyzer GFC-311E US EPA Approval Gas filter correlation method (IR method) High sensitivity measurement enabled with multi-reflection cell Easy-to-use touch panel Meas. range 0 - 5, 0 - 10, 0 - 20, 0 - 50, 0 - 100 ppm Carbon Monoxide Analyzer
DKK-TOA CGS-12 Calibration Gas Generator CGS-12   Calibrator for SO2/NOX/CO analyzers Built-in zero gas generator enables suction of ambient air & purification into zero gas Concentration of span gas (calibration) is freely adjustable between 1:100 & 1:10000 of component gas concentration   Calibration Gas Standards Generator
DKK-TOA GCO-200 Flue Gas CO/O2 Analyzer GCO-200 CO/O2  analyzer with an electric electrolysis CO sensor and a galvanic battery adapted O2 sensor Ease of maintenance, cost reduction attainable with simple constructed unit Meas. range CO: 0 - 200 to 2000 ppm (setting available at 100 ppm intervals)(assignable)  O2: 0 - 25% Flue Gas CO/O2 Analyzer
DKK-TOA GNC-224-1 Flue Gas Hydrogen Chloride Analyzer GNC-224-1 Continuous measurement of flue gas hydrogen chloride concentration produced in incineration plants by ion electrode method Small size chloride ion electrode and auto-cleaning function equipped Easy installation and maintenance attained with front panel operation Meas. Range 0 -  (50 - 2000) ppm 0 -  (10 - 50) ppm (optional) Flue Gas Hydrogen Chloride Analyzer
Lutron 50A/50mV SHUNT - ST-50 Adapter Series
Lutron Anemometer Adapter - AM-402 Adapter Series