By Brands

Sub Categories

Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable is most often two or more wires running side by side and bonded, twisted, or...
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
Performance characteristics: The box body and the lamp cap shell is made from high strength...
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
A refractometer is a laboratory or field device for the measurement of an index of refraction...
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
  Name SKU Description Category
Fluke i410 AC/DC Current Clamp Battery-powered Hall-effect probe measures 1A to 400 A 1mV/Amp output guarantees easy reading on your meter Take accurate current readings without breaking the circuit Maximum conductor Ø 32 mm CAT III 600 V safety rating Also available with softcase for DMM and clamp (i410 kit) One year warranty Current Clamp DMM Accys
Fluke i400s 400 A Current Clamp Companion to your scope or power quality meter to measure up to 400 A AC. Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating. Specially designed to offer maximum utility in a compact shape. Take accurate current readings without breaking the circuit. Soft non-slippery overmold handle. Optional PM9081/001 BNC/Banana adapter for DMM's. Two ranges: 40 A & 400 A, 10 & 1 mV/Amp output. Max. conductor Ø 32 mm. Current Clamp DMM Accys
Fluke i400 AC Current Clamp with Banana Plug Connections Companion to your DMM to measure up to 400 A AC 1mA/Amp output guarantees easy reading on you meter Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating Specially designed to offer maximum utility in a very compact shape Take accurate current readings without breaking the circuit Soft non-slippery overmold handle prevents from accidental touching live wiring Max. conductor Ø 32 mm Current Clamp DMM Accys
Fluke i310s Current Clamp Current Ranges: 30 A and 300 A ACRMS or DCMeasuring Ranges: ±45 A and 450 A Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A) Resolution: ±50 mA (40 A) to ±100 mA (400 A) Load Impedance: > 10 k Ohms and £ 100 pF Frequency Range (small signal): DC to 20 kHz (- 3 dB) Phase Shift below 1 kHz, < 2 degrees Temperature Coefficient: ±0.1% of reading / ±C Power Supply: 9 V Alkaline Current Clamp DMM Accys
Fluke i3000 Flex-36 AC Current Clamp, 915mm (36in.) Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm (7 in.) CAT III 600V safety rating Current Clamp DMM Accys
Fluke i3000s Flex 24 AC Current Clamp 610mm (24in.) Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm (7 in.) CAT III 600V safety rating Current Clamp DMM Accys
Fluke i3000 Flex-4PK AC Current Probe, 4 Pack Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm (7 in.) CAT III 600V safety rating Current Clamp DMM Accys
Fluke i30 AC/DC Current Clamp The i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC current The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement Current Clamp DMM Accys
Fluke i3000s AC Current Clamp An optional accessory for use with Fluke DMMs, PowerMeters and ScopeMeter test tools Measures ac current from 1A to 2400A RMS continuous PM9081/001 BNC to banana adapter included Current Clamp DMM Accys
Fluke I2500-18 IFlex Flexible Current Probe - 18" Expands the measurement range to 2500A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access CAT IV 600 V, CAT III 1000 V 7.5 mm coil diameter allows measurement in tight spaces Ergonomic design allows easy operation with one hand 1.8 m (6 ft) cable Three-year warranty Current Clamp DMM Accys
Fluke I2500-10 IFlex Flexible Current Probe - 10" Expands the measurement range to 2500A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access CAT IV 600 V, CAT III 1000 V 7.5 mm coil diameter allows measurement in tight spaces Ergonomic design allows easy operation with one hand 1.8 m (6 ft) cable Three-year warranty Current Clamp DMM Accys
Fluke i200s AC Current Clamp Companion to your scopemeter, power quality meter or digital multimeter to measure up to 200 A AC Included adapter for DMM's Two ranges: 20 A & 200A, 10 or 100 mV/ Amp output Take accurate current readings without breaking the circuit Max. conductor Ø 20 mm CAT III 600V safety rating Current Clamp DMM Accys
Fluke i2000-Flex AC Flexible Current Clamp Three ranges: 20A, 200 A & 2000 A, 1 mV, 10 mV & 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm CAT III 600V safety rating Current Clamp DMM Accys
Fluke i200 Small AC Current Clamp Companion to a DMM to measure up to 200 A AC 1mA per Amp output guarantees easy reading on you meter Take accurate current readings without breaking the circuit Max. conductor Ø 20 mm CAT III 600V safety rating Current Clamp DMM Accys
Fluke i1010 Kit AC/DC Current Clamp and Carry Case Kit i1010 1-600A AC rms, 1-1000A DC Current Clamp Zippered vinyl carry case with moveable divider Current Clamp DMM Accys
Fluke i1010 AC/DC Current Clamp Battery-powered dual Hall-effect, clamp-on probe measures dc current from 1-1000A; ac current from 1-600A ac rms Measures ac and dc current down to 1 amp with specified accuracy and is useable to 0.5A Output is 1 mV per amp dc or ac Jaws accept conductor size of 1 X 750 MCM ( 30 mm/1.18 in. diameter) or 2 X 500 MCM (2 X 25 mm/.98 in.) AC and DC accuracy: ± (2.0% of reading + 0.5A) Current Clamp DMM Accys
Fluke i1000s AC Current Probe Current Range: 100mA to 1000 Arms Basic Accuracy 48Hz to 65Hz: 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output Bandwidth: 5Hz to 100kHz Working Voltage: 600V AC rms Maximum Conductor Size: 54 mm (2.13 inch) diameter Safety Rating: 600V rms. CAT III per IEC 1010-02-032 Current Clamp DMM Accys
Fluke 90i-610s 1A to 600A AC/DC Current Probe Current Range: 1 to 600 A DC or AC Peak Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A) Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A Frequency Range: 40 Hz to 400 Hz Working Voltage: 600 V AC rms Maximum Conductor Diameter: 34 mm (1.34 inch) Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V Current Clamp DMM Accys
Fluke 80i-110s AC/DC Current Clamp Current Range: 0.1 to 100A DC or 0.1 to 70A AC Basic Accuracy (DC to 1kHz): 100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA 10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA40A to 80A +/- 12% of reading + 50mA80 to 100A +/- 15% of reading Output Signal: 10A range: 100mV/A | 100A range: 10mV/A Bandwidth: 1Hz to 20kHz Working Voltage: 600V AC rms Maximum Conductor Size: 1.8 mm (.46 inch) diameter Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II,... Current Clamp DMM Accys
Fluke 773 Milliamp Process Clamp Meter DC voltage measurement to verify 24 V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp Output mA signal enables a logging DMM or other device to record the 4 to 20 mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source a mA... Current Clamp Meters