By Brands

Sub Categories

Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable is most often two or more wires running side by side and bonded, twisted, or...
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
Performance characteristics: The box body and the lamp cap shell is made from high strength...
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
A refractometer is a laboratory or field device for the measurement of an index of refraction...
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
  Name SKU Description Category
Fluke i6000s Flex-36 AC Current Clamp (36in.) The i6000sflex is an AC current probe utilizing the Rogowski principle It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas Current Ranges: 60A/600A/6000A AC RMS Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A Frequency Range: 10 Hz to 50 kHz (- 3 dB) Load Impedance: 100 kOhm minimum Accuracy (at +25°C): ±1%... Current Clamp DMM Accys
Fluke i800 AC Current Clamp Probe Measures AC current from 100mA to 800 A rms 30 Hz to 10 kHz frequency range CAT III 600 V rating Accepts up to 54 mm (2.1 in) diameter conductor size 1000:1 conversion factor for easy calculation Rugged positive action design Current Clamp DMM Accys
Fluke 140S-PR Clamp-on Current Transformer Operates with the Fluke 1750 Power Recorder It supplies accurate nonintrusive measurement of ac current The probe has a current range from 0.05 A to 40 A The frequency range is 40 Hz to 5 kHz The clamp is approved for CAT III 600 V Current Clamp DMM Accys
Fluke 3100R Clamp-on Current Transformer Current range: 1-1000A Accuracy: 1% RDG +/- 0.05% FS Frequency response: 5 kHz Jaw opening: 2" dia. (5 cm) Current Clamp DMM Accys
Fluke 3112RPM Flexi-CT™ Flexible Current Transformer Current range: 2-100 Accuracy: 1% RDG +/- 0.5% FS Frequency response: 7 kHz Length: 48” (1.2 cm) Current Clamp DMM Accys
Fluke 3120R Clamp-on Current Transformer Current range: 0.05-200A Accuracy: 1% RDG +/- 0.3% FS Frequency response: 5 kHz Jaw opening: .78” dia. (2 cm) Current Clamp DMM Accys
Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe For the Fluke 1750 Power Recorder The Fluke 3210-PR-TF 1000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3210PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3300 Clamp-on Current Transformer Current range: 10-3000A Accuracy: 2% RDG +/- 0.05% FS Frequency response: 5 kHz Jaw opening: 3.5 x 4.5” dia. (9 x 11 cm) Current Clamp DMM Accys
Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe, 2 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3212-PR-TF 5000A Flex Thin Flex Current Probe, 4 Feet Long For the Fluke 1750 Power Recorder The Fluke 3310-PR-TF 5000A Flex Thin Flex Current Probe  is an ac current probe utilizing the Rogowski principle. The Fluke 3310PRTF Probe is designed for use with the Fluke 1750 Power Recorder and measures current from very low frequencies up to the 50th harmonic of a 50/60 Hz power supply. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and around large conductors. Current Clamp DMM Accys
Fluke 3583R Split-Core Current Transformers Current range: 0.01 – 10A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3584R Split-Core Current Transformers Current range: 0.1 – 40A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke 3585R Split-Core Current Transformers Current range: 0.5 – 1-0A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke 373 True-RMS 600A/600V AC Clamp Meters 600 A ac current measurement with fixed jaw 600 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement to 6000Ω with continuity detection 1000 µF capacitance measurement State of the art signal processing allows for use in noisy electrical environments while providing stable readings Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch... Current Clamp Meters