Digital Multimeter PCE-DM 7

Category: Digital Multimeter
Digital Multimeter / true RMS measurement / temperature measurement / automatic and manual measurement range selection / simple operation / bar graph display

The Digital Multimeter provides precise measurements for a variety of parameters, including AC and DC voltage, direct and alternating current, frequency, resistance, capacitance and temperature. Our Digital Multimeter has a hold function for saving measurement results as well as non-contact voltage detection (NCV).

The device enables both automatic and manual measurement range selection and is equipped with an easy-to-read 2.8-inch LCD with backlight. With a sampling rate of three measurements per second, it delivers quick results and switches off automatically after five minutes of inactivity to extend the battery life. In addition, the Digital Multimeter offers a dual display: a bar graph for quick visual assessments and a numerical display for precise readings.

The Digital Multimeter is powered by two 1.5 V batteries and is designed for easy one-handed operation. The compact dimensions of 140 x 70 x 35 mm make the Digital Multimeter a practical tool for everyday use by electricians and hardware developers as well as in other technical applications.

Highlights

- non-contact voltage detection
- temperature measurement
- automatic power off
- automatic and manual measurement range selection
- hold function
- 2.8-inch LC display with backlight
- small and compact design

Specification

Direct voltage DC  
Measurement range up to   0 ... 9,999 mV
Resolution   0,001 mV
Accuracy   ±(0.5 % of Rd +3 digits)
   
Direct voltage DC  
Measurement range up to   10 ... 99,99 mV
Resolution   0,01 mV
Accuracy   ±(0.5 % of Rd +3 digits)
   
Direct voltage DC  
Measurement range up to   100 ... 999,9 mV
Resolution   0,1 mV
Accuracy   ±(0.5 % of Rd +3 digits)
   
Direct voltage DC  
Measurement range up to   1 ... 9,999 V
Resolution   0,001 V
Accuracy   ±(0.5 % of Rd +3 digits)
   
Direct voltage DC  
Measurement range up to   10 ... 99,99 V
Resolution   0,01 V
Accuracy   ±(0.5 % of Rd +3 digits)
   
Direct voltage DC  
Measurement range up to   100 ... 999,9 V
Resolution   0,1 V
Accuracy   ±(0.5 % of Rd +3 digits)
   
Direct current DC  
Measurement range up to   0 ... 9999 µA
Resolution   1 µA
Accuracy   ±(0.8 % of Rd +3 digits)
   
Direct current DC  
Measurement range up to   10 ... 99,99 mA
Resolution   0,01 mA
Accuracy   ±(0.8 % of Rd +3 digits)
   
Direct current DC  
Measurement range up to   100 ... 999,9 mA
Resolution   0,1 mA
Accuracy   ±(1 % of Rd +3 digits)
   
Direct current DC  
Measurement range up to   1 ... 9,999 A
Resolution   0,001 A
Accuracy   ±(1 % of Rd +3 digits)
   
Capacity  
Measurement range up to   0 ... 9,999 nF
Resolution   0,001 nF
Accuracy   ±(5.0 % of Rd +20 digits)
   
Capacity  
Measurement range up to   10 ... 99,99 nF
Resolution   0,01 nF
Accuracy   ±(2.0 % of Rd +5 digits)
   
Capacity  
Measurement range up to   100 ... 999,9 nF
Resolution   0,1 nF
Accuracy   ±(2.0 % of Rd +5 digits)
   
Capacity  
Measurement range up to   1 ... 9,999 µF
Resolution   0,001 µF
Accuracy   ±(2.0 % of Rd +5 digits)
   
Capacity  
Measurement range up to   10 ... 99,99 µF
Resolution   0,01 µF
Accuracy   ±(2.0 % of Rd +5 digits)
   
Capacity  
Measurement range up to   100 ... 999,9 µF
Resolution   0,1 µF
Accuracy   ±(2.0 % of Rd +5 digits)
   
Capacity  
Measurement range up to   1 ... 9,999 mF
Resolution   0,001 mF
Accuracy   ±(5.0 % of Rd +5 digits)
   
AC voltage  
Measurement range up to   0 ... 9,999 mV
Resolution   0,001 mV
Accuracy   ±(1 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
AC voltage  
Measurement range up to   10 ... 99,99 mV
Resolution   0,01 mV
Accuracy   ±(1 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
AC voltage  
Measurement range up to   100 ... 999,9 mV
Resolution   0,1 mV
Accuracy   ±(1 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
AC voltage  
Measurement range up to   1 ... 9,999 V
Resolution   0,001 V
Accuracy   ±(1 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
AC voltage  
Measurement range up to   10 ... 99,99 V
Resolution   0,01 V
Accuracy   ±(1 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
AC voltage  
Measurement range up to   100 ... 750 V
Resolution   0,1 V
Accuracy   ±(1 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
Alternating current AC  
Measurement range up to   0 ... 9999 µA
Resolution   1 µA
Accuracy   ±(1 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
Alternating current AC  
Measurement range up to   10 ... 99,99 mA
Resolution   0,01 mA
Accuracy   ±(1 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
Alternating current AC  
Measurement range up to   100 ... 999,9 mA
Resolution   0,1 mA
Accuracy   ±(1.2 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
Alternating current AC  
Measurement range up to   1 ... 9,999 A
Resolution   0,001 A
Accuracy   ±(1.2 % of Rd +3 digits)
Frequency range   40 ... 1000 Hz
   
Resistance  
Measurement range up to   0 ... 99,99 Ω
Resolution   0,01 Ω
Accuracy   ±(1 % of Rd +3 digits)
   
Resistance  
Measurement range up to   100 ... 999,9 Ω
Resolution   0,1 Ω
Accuracy   ±(0.5 % of Rd +3 digits)
   
Resistance  
Measurement range up to   1 ... 9,999 kΩ
Resolution   0,001 kΩ
Accuracy   ±(0.5 % of Rd +3 digits)
   
Resistance  
Measurement range up to   10 ... 99,99 kΩ
Resolution   0,01 kΩ
Accuracy   ±(0.5 % of Rd +3 digits)
   
Resistance  
Measurement range up to   100 ... 999,9 kΩ
Resolution   0,1 kΩ
Accuracy   ±(0.5 % of Rd +3 digits)
   
Resistance  
Measurement range up to   1 ... 9,999 M Ω
Resolution   0,001 M Ω
Accuracy   ±(1.5 % of Rd +3 digits)
   
Resistance  
Measurement range up to   10 ... 99,99 M Ω
Resolution   0,01 M Ω
Accuracy   ±(3.0 % of Rd +5 digits)
   
Duty cycle  
Measurement range up to   1 ... 99 %
Resolution   0,1 %
Accuracy   ±(0.1 % of Rd +2 digits)
   
Frequency  
Measurement range up to   0 ... 99,99 Hz
Resolution   0,01 Hz
Accuracy   ±(0.1 % of Rd +2 digits)
   
Frequency  
Measurement range up to   100 ... 999,9 Hz
Resolution   0,1 Hz
Accuracy   ±(0.1 % of Rd +2 digits)
   
Frequency  
Measurement range up to   1 ... 9,999 kHz
Resolution   0,001 kHz
Accuracy   ±(0.1 % of Rd +2 digits)
   
Frequency  
Measurement range up to   10 ... 99,99 kHz
Resolution   0,01 kHz
Accuracy   ±(0.1 % of Rd +2 digits)
   
Frequency  
Measurement range up to   100 ... 999,9 kHz
Resolution   0,1 kHz
Accuracy   ±(0.1 % of Rd +2 digits)
   
Frequency  
Measurement range up to   1 ... 5 MHz
Resolution   0,001 MHz
Accuracy   ±(0.1 % of Rd +2 digits)
   
Temperature  
Measurement range up to   -20 ... +1000 °C
Resolution   1 °C
Accuracy   ±(2.5 % of Rd +5 digits)
   
Temperature  
Measurement range up to   -4 ... +1832 °F
Resolution   1 °F
Accuracy   ±(2.5 % of Rd +5 digits)
   
General technical data  
Measuring functions   HOLD
Display type   LCD with backlight
Display size   2,8 Inch
Measuring rate   3 x per second
Automatic power-off   5 min
Safety standard   CAT II 1000 V, CAT III 600 V
Measurement range selection   Automatic, Manual
Menu language   English, English (GB)
Protection class (device)   IP20
Weight   175 g
Operating conditions   0 ... 40 °C , 0 ... 75 % RH
Storage conditions   -20 ... 60 °C , 0 ... 80 % RH
(Rechargeable) battery   2 x 1,5 V AA battery , Alkali-manganese
Capacity   3000 mAh
Dimensions ( L x W x H )   140 x 70 x 35 mm
Ask about this product