Ultrasonic flowmeter with 32 GB data memory / measuring range ±32 m/s /reproducibility ±0.5 % of measured value / different measuring probes / alarm limit values /2.8 " LC display / for all media / optionally with DAkkS or ISO calibration certificateThe ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob.During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software.In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate.PCE-TDS 200 S SENSORSmall sensor pair for pipe diameters DN 15 ... 100 / 20 ... 108 mm. Suitable for particularly small pipes. The sensors have a particularly small dimension of 45 x 30 x 30 mm and a temperature resistance of -30 ... 160 °C. Thanks to the magnets on the underside, the sensors can be mounted on ferrous metals. In addition, the sensors for the ultrasonic flowmeter can be connected to the pipe by means of detachable cable ties.PCE-TDS 200 M SENSORMedium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. With the built-in magnets on the sensors for the ultrasonic flow meter, they can be attached to ferrous pipes. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
Highlights
- Measuring range ±32 m/s- USB-C interface for data transfer- Optional software for analysing the measured values- Reproducibility ±0.5 % of measured value- Heat quantity measurement- Data memory for 10 million measuring points- individually adjustable alarm limits- optionally with ISO or DAkkS calibration certificateSpecification
Speed Measuring range -32 ... +32 m/s Resolution 0.001 m/s Accuracy DN ≥50 mm: ±1.5 % of Rd for velocities >0.3 m/s / DN <50 mm: ±3.5 % of Rd for velocities >0.3 m/s Type K temperature Measuring range -100 ... +1370 °C Resolution 0,1 °C Accuracy ±0.4 % Temperature J-type Measuring range -100 ... +1150 °C Resolution 0,1 °C Accuracy ±0.4 % Temperature S-type Measuring range 0 ... 1500 °C Resolution 0,1 °C Accuracy ±0.5% Temperature R-type Measuring range 0 ... 1700 °C Resolution 0,1 °C Accuracy ±0.5% Temperature E-type Measuring range -100 ... +900 °C Resolution 0,1 °C Accuracy ±0.4 % Temperature T-type Measuring range -100 ... +400 °C Resolution 0,1 °C Accuracy ±0.4 % Temperature N-type Measuring range -100 ... +1150 °C Resolution 0,1 °C Accuracy ±0.4 % Temperature B-type Measuring range 600 ... 1800 °C Resolution 0,1 °C Accuracy ±0.5% Ultrasonic sensor Designation PCE-TDS 200 S SENSOR Pipe diameter DN 15 ... 100 mm / Ø 20 ... 108 mm Dimension 45 x 30 x 30 mm Battery type Ultrasound Frequency 1 MHz Operating temperature -30 ... 160 °C Sensor cable length 5 m Ultrasonic sensor Designation PCE-TDS 200 M SENSOR Pipe diameter DN 50 ... 700 mm / Ø 57 ... 720 mm Dimension 70 x 40 x 40 mm Battery type Ultrasound Frequency 1 MHz Temperature -30 ... 160 °C Sensor cable length 5 m General technical data Measuring functions Flow velocity, Volume flow, Volume, Temperature, Heat output, Heat quantity Units metric, imperial Units additional information Dimensions: mm, in
Flow velocity: m/s, ft/s
Temperature: °C/°F
Heat quantity: K, kJ, MJ, Wh, kWh, MWh, Btu, kBtu, MBtu
Heat output: W, kW, MW, J/h, kJ/h MJ/h, Btu/h, kBtu/h, MBtu/h
Volume flow: m³, l, gal, igl, mgl, cf, bal, ib, ob
Volume: m³, l, gal, igl, mgl, cf, bal, ib, ob
Time specification: seconds, minutes, hours, days
Cost display: EUR, GBP, USD, Turkish Lira, Zloty, YenDisplay size 2,8 Inch Storage medium Internal memory Storage capacity 32 GB Storage interval from 1 s Storage interval to 12 h Interface USB-C Pipe material Steel, Cast iron, Stainless steel, Aluminium, Brass, Copper, PVC, Iron, Nickel, Titanium, Zinc, Acrylic, Polyethylene, Polypropylene, Nylon, User-defined (manual entry of the transversal sound velocity of the pipe material) Pipe material additional information Inner lining of the pipe:
- No lining
- Epoxy resin
- Rubber
- Mortar
- Polystyrene
- Polyethylene
- Polytetrafluoroethylene
- Polyurethane
- Polypropylene
- Customised (manual entry of the longitudinal sound velocity of the inner lining of the pipe)Measured medium Water, Seawater, Oil, Crude oil, Methanol, Ethanol, Diesel, Petrol, Petroleum, User-defined (manual entry of the sound velocity of the medium) Operating time 10 h Automatic power-off from...to 1 ... 15 min. Measuring method Z, V, N, W Alarm optical, Acoustic Alarm modes Undercut, overflow, within, beyond Reproducibility ±0.5% Menu language Turkish, English, Polish, Spanish, German, Chinese, Russian, Japanese, French, Danish, Italian, Dutch, Portuguese Protection class (device) IP52 Power supply USB 5 V DC, 500 mA Connector type Device-europlug (Rechargeable) battery 1 x 3,7 V LP785060 , Lithium polymer battery Capacity 2500 mAh Performance 9,25 Wh Operating conditions -20 ... 65 °C , 10 ... 95 % RH Storage conditions -20 ... 65 °C , 10 ... 95 % RH Dimensions ( L x W x H ) 165 x 85 x 32 mm Weight 263,5 g Delivery Scope
1 x Ultrasonic Flow Meter PCE-TDS 200+ SM1 x Flow sensors PCE-TDS 200 S SENSOR (pair)1 x Flow sensors PCE-TDS 200 M SENSOR (pair)2 x Temperature sensor TF-RA3302 x 5 m connection cable2 x detachable cable ties1 x power supply unit1 x USB-C cable1 x ultrasonic contact gel1 x PCE measuring tape1 x plastic case1 x instruction manual