Products
Current probes (AC/DC)
| |
Name |
SKU |
Description |
Category |
|
|
|
TEN011-400A-AC/DC Current Transducer
|
|
Product Description
CAT III 600V AC/DC current ranges 40A and 400A. Maximum conductor size 30mm. Low battery indication. |
Clamp meters
|
|
|
|
PRO0013 - CM-05 (CM05) DC/AC CURRENT PROBE
|
|
■ Accurate DC/AC current probe for current measurement.
■ 10mADC, 1mAAC high resolution.
■ One touch zero for DCA adjustment.
■ 23 mm diameter jaw.
■ Easy single rotary switch for any function selection.
■ Connect to an oscilloscope for waveform observation.
■ Connect to a datalogger/DMM for recording or monitoring. |
Current probes (AC/DC)
|
|
|
|
CEN0045A-25V2-18" FLEXIBLE CURRENT PROBE 0~3000A (WITHOUT DISPLAY UNIT)
|
|
FEATURES
• Measurement Ranges: 30A/300A/3000A AC• Output Sensitivity: 100mV/10mV/1mV per Amp• 8.5mm coil diameter allows measurement in tight spaces (Double insulated)• 10”flexible sensor fit around conductors up to 3.2”in diameter• 18”flexible sensor fit around conductors up to 5.8”in diameter• Dual banana plug termination for direct input into DMM• Flashing LED low battery... |
Current probes (AC/DC)
|
|
|
|
CEN0039-26V2 18" FLEXIBLE CURRENT METER 3000A (SAME AS FLUKE IFLEX )-26
|
|
FEATURES
• Measurement Ranges: 30A/300A/3000A AC• Output Resolution (LCD Display): 0.01A/0.1A/1A• 8.5mm coil diameter allows measurement in tight spaces (Double insulated)• 10” flexible sensor fit around conductors up to 3.2”in diameter• 18” flexible sensor fit around conductors up to 5.8”in diameter• TRMS Reading
SPECIFICATIONS
Range
Resolution
Accuracy
30A/300A/3000A
0.01A/0.1A/1A
3%rdg ± 5dgts
Frequency Range:... |
Current probes (AC/DC)
|
|
|
|
SEW0019-PD40AMV2 DC40KV HIGH VOLTAGE DETECTOR WITH BUILT-IN DCV INDICATOR (PD-40AM)
|
|
FEATURES
Measures positive polarity DC voltages up to 40kV.
Lightweight and rugged.
2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.
SPECIFICATIONS
Input impedance
600 MΩ
Attenuation ratio
40000 : 1
Accuracy
DCV (0 ~ 20kV) ± 2%DCV (20kV ~ 40kV) ± 3%
Max. working voltage
DC 40kV
Operating... |
Current probes (AC/DC)
|
|
|
|
SEW0028 DC40KV AC28V HIGH VOLTAGE PROBE (HV PROBE) DC40KV/AC28KV FOR DMM - 28
|
|
FEATURES
Measures both AC and DC voltages with digital multitester.
Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.
Lightweight and rugged.
2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
SPECIFICATIONS
Input impedance
1000 MΩ
Attenuation ratio
1000 : 1
Accuracy
DCV (0 ~ 20kV) ± 1%DCV (20kV ~ 40kV) ± 2%ACV (0 ~ 28kV) typically ± 5% at 50/60... |
Current probes (AC/DC)
|
|
|
|
SEW0028B DC30KV AC20KV HIGH VOLTAGE PROBE (HV PROBE) DC30KV/AC20KV FOR DMM - 20
|
|
FEATURES
Measures both AC and DC voltages with digital multitester.
Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.
Lightweight and rugged.
2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
SPECIFICATIONS
Input impedance
500 MΩ
Attenuation ratio
1000 : 1
Accuracy
DCV (0 ~ 20kV) ± 1%DCV (20kV ~ 30kV) ± 2%ACV (0 ~ 20kV) typically ± 5% at 50/60... |
Current probes (AC/DC)
|
|
|
|
SEW0028C DC30KV AC20KV HIGH VOLTAGE PROBE (HV PROBE) DC30KV/AC20KV FOR SCOPE/OSCILLOSCOPES- 20S
|
|
FEATURES
Measures both AC and DC voltages with oscilloscopes.
Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.
Lightweight and rugged.
2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
SPECIFICATIONS
Input impedance
500 MΩ
Attenuation ratio
1000 : 1
Accuracy
DCV (0 ~ 20kV) ± 1%DCV (20kV ~ 30kV) ± 2%ACV (0 ~ 20kV) typically ± 5% at 50/60... |