Fluke TP88 Rigid Back Probe Pins
|
|
Slides onto test probes measuring 2 mm (0.08 inches)
Tested to 60 V DC
|
Automotive Accessories
|
|
|
Fluke TP82 Insulation Piercing Clip Set
|
|
Banana jack accepts all DMM and banana jack leads
Non-rotating banana jack prevents leads from tangling, allowing you to tighten/loosen clamp while still connected to the test lead
For use with test leads with 2 mm probes
Tested to 60 V DC
|
Automotive Accessories
|
|
|
Fluke TP81 Insulation Piercing Clip Set
|
|
Banana jack accepts all DMM and banana jack leads
Non-rotating banana jack prevents leads from tangling, allowing you to tighten/loosen clamp while still connected to the test lead
For use with test leads with 4 mm banana plugs
Tested to 60 V DC
|
Automotive Accessories
|
|
|
Fluke TP40 Automotive Back Probe Pins (five)
|
|
Banana jack accepts all DMM and banana jack leads
Tested to 60 V DC
|
Automotive Accessories
|
|
|
Fluke TLK282 SureGrip™ Deluxe Automotive Test Lead Kit
|
|
Includes:
TP81 Insulation Piercing Clip Set
TP40 Automotive Back Probe Pins (five)
TL224 Suregrip™ Silicone Test Lead Set
TP220 Suregrip™ Test Probe Set
AC220 Suregrip™ Alligator Clip Set
AC285 Suregrip™ Large Jaw Alligator Clip Set
AC280 Suregrip™ Hook Clip Set Soft Case
|
Automotive Accessories
|
|
|
Fluke TLK281 SureGrip™ Automotive Test Lead Kit
|
|
Includes:
TP81 Insulation Piercing Clip Set
TL224 Suregrip™ Silicone Test Lead Set
TP220 Suregrip™ Test Probe Set
AC220 Suregrip™ Alligator Clip Set
AC285 Suregrip™ Large Jaw Alligator Clip Set Soft Case
|
Automotive Accessories
|
|
|
Fluke TL82 Automotive Pin & Socket Adapter Set
|
|
Retractable shrouded test leads
Complete set of 8 pin-and-socket adapters with flexible tips
One red and one black in the following sizes:
Size 22 contact 0.030 in (0.76 mm) rated 5 A
Size 20 contact 0.040 in. (1.02 mm) rated 7.5A
Size 16 contact 0.063 in. (1.60 mm) rated 13 Tested to 60 V DC
Size 12 contact 0.093 in. (2.36 mm) rated 23
|
Automotive Accessories
|
|
|
Fluke TL28A Automotive Test Lead Set
|
|
Large jaws, long leads and a piercing probe
Solid, spring-loaded copper clips with a wide 12.7 mm (.50") jaw opening and serrated teeth
Large piercing needle for penetrating larger gauge wires
1.5 m (60"), silicone-insulated leads, useable from -80 °C to +150 °C (-112 °F to +302 °F)
Rated for 30 V, 10 A. One red, one black
Flexible silicone insulated leads are heat and cold resistant
Cat I 30 V, 10 A
|
Automotive Accessories
|
|
|
Fluke RPM80 Inductive Pick-Up/External Trigger
|
|
Provides RPM readings |
Automotive Accessories
|
|
|
Fluke PV350 Pressure Vacuum Module
|
|
Compatible with all Fluke and most popular DMMs
Digital pressure and vacuum measurements in a single module
Transducer sealed in 316 stainless steel compatible with variety of liquids and gases
Measures vacuum to 76 cm Hg
Displays results in English (psig of Hg) or metric (kPa or cm Hg) units
Measures pressure to 3447 kPa (500 psig)
One year warranty
|
Automotive Accessories
|
|
|
Fluke BP881 BNC to Male Double Stacking Banana Plug
|
|
Allows for hands-free testing in controlled voltage environments 500 VRMS maximum
Banana plug is nickel-plated, beryllium copper for low contact resistance
The BNC shell is plated for tarnish resistance
Operating temperature +50 °C (+122 °F) maximum
|
Automotive Accessories
|
|
|
Fluke BP880 BNC to Female Double Stacking Banana Plug
|
|
Allows for hands-free testing in controlled voltage environments 500 VRMS maximum
Banana plug is nickel-plated, beryllium copper for low contact resistance
The BNC shell is plated for tarnish resistance
Operating temperature +50 °C (+122 °F) maximum
|
Automotive Accessories
|
|
|
Fluke 90i-610s 1A to 600A AC/DC Current Probe
|
|
Current Range: 1 to 600 A DC or AC Peak
Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A)
Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A
Frequency Range: 40 Hz to 400 Hz
Working Voltage: 600 V AC rms
Maximum Conductor Diameter: 34 mm (1.34 inch)
Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V
|
Automotive Accessories
|
|
|
Fluke SV225 Stray Voltage Adapter
|
|
Stray voltage can appear in electrical installations, due to the capacity between wires
This may result in erroneous readings on high impedance meters
The SV225 solves this without compromising safety
On energized wires, the meter will indicate the real voltage
On non-energized circuits the meter will read close to zero (even if there are stray voltages)
It can be used with all modern meters with standard input spacing.
Rated CAT III 1000V, CAT IV 600 V
|
Batteries, Charges and Adapters
|
|
|
Fluke PM9080 Optically Isolated RS-232 Adapter
|
|
Safety designed serial interface for digital hard-copy output to serial printer or remote control and data exchange with a PC.
Compatible with all Fluke ScopeMeter® test tools, with Power Quality Analyzers, Graphical MultiMeters and MultiFunction Counters.
Hard Copy: ScopeMeter test tools support Epson FX/LQ Series, LaserJet and DeskJet compatible printers
Remote control: Waveforms, Scope and Meter measurements, Front Set-ups and performance verification/calibration
Transfer rate:... |
Batteries, Charges and Adapters
|
|
|
Fluke TI-CAR Charger
|
|
For the ultimate flexibility in the field - recharge your thermal imager wherever and whenever you need to
For use with: Ti32, Ti25, Ti10, TiR32, TiR1, TiR
|
Batteries, Charges and Adapters
|
|
|
Fluke PM8907 Line Voltage Adapter/Battery Charger
|
|
Mains (Line Voltage) - 801 (Europe) 230V ± 10% - 803 (North America) 120V ± 10% - 804 (United Kingdom) 230V ± 10% - 806 (Japan) 100V ± 10% - 807 (Australia) 240V ± 10% - 808 (Universal) switchable 115V± 15% or 230V ± 15% - 808 is equipped with a male receptacle plug that must be connected to a line cord appropriate for local use.
Line cord not included
A North American line plug adapter is included
|
Batteries, Charges and Adapters
|
|
|
Fluke PM8907 Line Voltage Adapter/Battery Charger
|
|
Mains (Line Voltage) - 801 (Europe) 230V ± 10% - 803 (North America) 120V ± 10% - 804 (United Kingdom) 230V ± 10% - 806 (Japan) 100V ± 10% - 807 (Australia) 240V ± 10% - 808 (Universal) switchable 115V± 15% or 230V ± 15% - 808 is equipped with a male receptacle plug that must be connected to a line cord appropriate for local use.
Line cord not included
A North American line plug adapter is included
|
Batteries, Charges and Adapters
|
|
|
Fluke BE9005 Battery Eliminator
|
|
7.5V dc battery eliminator for operation of calibrator from 120 volt AC line
UL/CSA recognized
For use in North America; 120V ac 60 Hz lines
3.8" x 2.5" x 2.2" (96 mm x 63 mm x 56 mm); 72" (1.8m) cord
Weight: 1 lb/0.5 kg
One year warranty
|
Batteries, Charges and Adapters
|
|
|
Fluke BC190 Line Voltage Adapter/Battery Charger
|
|
Mains (Line Voltage) - BC190/801 (Europe) 230V ± 10% - BC190/803 (North America) 120V ± 10% - BC190/804 (United Kingdom) 230V ± 10% - BC190/806 (Japan) 100V ± 10% - BC190/807 (Australia) 230V ± 10% - BC190/808 (Universal) switchable 115V± 15% or 230V ± 15% - 808 are equipped with a male receptacle plug that must be connected to a line cord appropriate for local use. (Line cord not included) |
Batteries, Charges and Adapters
|
|