Fluke 789 Process Meter
|
|
24 V Loop power supply
HART mode setting with loop power (adds 250 ohm resistor)
100 % larger dual display
1,200 ohm drive capability on mA source
Enhanced backlight with two brightness settings
0-100 % mA Span Check buttons to toggle between 4 and 20 mA
Infrared I/O serial port compatible with FlukeView® Forms Software Version 2.1 (available Feb. 2003)
Externally accessible fuses for easy replacement
DMM designed to meet 1000 volt IEC 1010 CAT III standards
Precision 1000 V, 440 mA... |
Calibrators/Injectors
|
|
|
PRO0005-Process Calibrator Voltage/Current/Temperature Calibrator/Injector
|
|
4-20mA, 0-20mA, 0-24mA with 1 m A resolution
0-100mV with 10 m V resolution
0-12V with 1mV resolution
Thermocouple K,J,E,T TYPE 1 o C 1 o F resolution
Frequency 2 - 50,000Hz
|
Calibrators/Injectors
|
|
|
PRO0045-ICAL DOCUMENTING MULTIFUNCTION CALIBRATOR/ARBITRARY FUNCTION GENERATOR
|
|
iCal is a multifunction calibrator and an arbitrary function generator
Unique mapping function allows direct calibration of voltage and temperature
Source: mA(4 to 20mA), V(0 to 15V, 0 to 70mV), Hz, sine wave, square wave, triangular wave, truncated sine wave, and user programmable waveforms
Measurements: Current (mA), voltage (V, mV), temperature (°C, and °F)
Frequency range: (0.3 Hz to 20 kHz)
Programmable frequency and phase synthesis of single tone and DTMF for devices such as MP3,... |
Calibrators/Injectors
|
|
|
LUT0009-Voltage/Current Loop Calibrator
|
|
VOLTAGE/CURRENT CALIBRATOR * Current source : 0 to 24 mA, 2 ranges. * Current measurement : 0 to 24 mA, 2 ranges. * Power (12 V) and current measurement of two wire loop : 0 to 24 mA, 2 ranges. * DC mV source : -199.9mV to +199.9mV. |
Calibrators/Injectors
|
|
|
SPM028-World’s Advanced Temperature & Loop Calibrator (K,E,J,T,N,R,S,B,C,D,G,L,U,11RTD/PT)
|
|
A highly integrated multifunction calibrator featuring several patented technologies. The Multifunction temperature calibrator is an ultra-compact and easy to use hand-held device for sourcing, simulating and measuring temperature and electrical signals. It is with Cellphone-like menu, task management function; SPM028 is ideal solution for calibrating, maintaining, and troubleshooting in both field and laboratory.
Simulates and measures 13 thermocouples(K、... |
Calibrators/Injectors
|
|
|
SPM029-World’s Advanced Loop Calibrator (ULTRA-HIGH RESOLUTION 0.1uA,0.1mV,1uV),U,11RTD/PT)
|
|
SPM029 multifunction loop calibrator is a process tool for measuring, sourcing and simulating loop current, mV/ V, loop integrity, and also perform switch testing. Its smart phone-like menu and interface makes it simple and easy to use. SPM029 multifunction loop calibrator is an idea for calibrating, maintaining, and troubleshooting various loop devices in the field.
Measuring and sourcing loop current, mV and V independently. 24V loop power supply with independent measuring and sourcing... |
Calibrators/Injectors
|
|
|
SEW0090-Multifunction Loop Calibrator
|
|
FEATURES
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
SPECIFICATIONS
DC Current (1kΩ Max Load, 24v Loop Supply)
Range
0-4mA / 4-20mA / 20-24mA
... |
Calibrators/Injectors
|
|
|
SEW0084-ELECTRICITY TEST BOX
|
|
FEATURES
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.
SPECIFICATIONS
RCD Testing
Range
10mA @ 150ms 30mA @ 150ms 150mA... |
Test Box/Trainers
|
|
|
TEN590-TM-100V2 SOUND LEVEL CALIBRATOR FOR CLASS 2 SOUND LEVEL METER
|
|
Setting standard sound level at 94dB and 114dB.According Standard ANSI S1 4-1984 and IEC 942 1988 Class 21/2 inch microphone adapters provided.Low battery indicator.
Class 2 Dual Level Calibrator
|
Sound calibrator
|
|
|
TEN591-ST-120 Class1 Sound Level Calibrator
|
|
IEC 60942:2003 Class1/ANSI S1.40-1984. ● Output sound level : at 94dB and 114dB. ● Frequency : 1KHZ ±1%, Class1, A ● Accuracy : 94±0.3dB 114±0.5dB Specifications ● Sound pressure levels : at 94dB and 114dB. ● For 1/2" condenser microphone calibration. ● Low battery indication. ● Harmonic waves distortion ±3%. ● Output feedback detection. ● Power: 9V battery 006P or IEC6F22 or NEDA 1604 ● Operation environments : 23.0oC ±3oC <85%RH ,850mbar~1050mbar, ≦2000M |
Sound calibrator
|
|