Current Clamp DMM Accys

  • Filter
  Name SKU Description Category
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke i800 AC Current Clamp Probe Measures AC current from 100mA to 800 A rms 30 Hz to 10 kHz frequency range CAT III 600 V rating Accepts up to 54 mm (2.1 in) diameter conductor size 1000:1 conversion factor for easy calculation Rugged positive action design Current Clamp DMM Accys
Fluke i6000s Flex-36 AC Current Clamp (36in.) The i6000sflex is an AC current probe utilizing the Rogowski principle It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas Current Ranges: 60A/600A/6000A AC RMS Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A Frequency Range: 10 Hz to 50 kHz (- 3 dB) Load Impedance: 100 kOhm minimum Accuracy (at +25°C): ±1%... Current Clamp DMM Accys
Fluke i6000s Flex-24 AC Current Clamp (24in.) The i6000sflex is an AC current probe utilizing the Rogowski principle It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas Current Ranges: 60A/600A/6000A AC RMS Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A Frequency Range: 10 Hz to 50 kHz (- 3 dB) Load Impedance: 100 kOhm minimum Accuracy (at +25°C): ±1%... Current Clamp DMM Accys
Fluke i5sPQ3 AC 5A Current Clamp (3 Pack) Low level current clamp measures up to 5 A ac Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches) Take accurate readings without breakings the circuit CAT III 600 V (For insulated conductors only) Current Clamp DMM Accys
Fluke i5s AC Current Clamp Expand the use of your Fluke 430 series power quality tool with this 5A ac current clamp Specially configured to provide low current accuracy while taking measurements on secondary current transformers Low level current clamp measures up to 5A ac Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches) Take accurate readings without breakings the circuit CAT III 600 V (For insulated conductors only) Current Clamp DMM Accys
Fluke i430-Flexi-TF-4PK 6000 A Flexible AC Current Probe Current Range: 6000 A AC Frequency Range: 10 Hz to 7 kHz (-3 dB) Accuracy: +/- 1% of reading (@25 C, 50 Hz) i430-Flexi-TF works with: Fluke 434-II Series II Three-Phase Energy Analyzer Fluke 435-II Series II Three-Phase Power Quality and Energy Analyzer Fluke 437-II Series II 400 Hz Three-Phase Power Quality and Energy Analyzer Current Clamp DMM Accys
Fluke i430-Flexi-TF 6000 A Flexible AC Current Probe Current Range: 6000 A AC Frequency Range: 10 Hz to 7 kHz (-3 dB) Accuracy: +/- 1% of reading (@25 C, 50 Hz) i430-Flexi-TF works with: Fluke 434-II Series II Three-Phase Energy Analyzer Fluke 435-II Series II Three-Phase Power Quality and Energy Analyzer Fluke 437-II Series II 400 Hz Three-Phase Power Quality and Energy Analyzer Current Clamp DMM Accys
Fluke i410-Kit AC/DC Current Clamp and Carry Case Kit i410 1-400A AC rms, 1-400A DC Current Clamp Zippered vinyl carry case with moveable divider Current Clamp DMM Accys
Fluke i410 AC/DC Current Clamp Battery-powered Hall-effect probe measures 1A to 400 A 1mV/Amp output guarantees easy reading on your meter Take accurate current readings without breaking the circuit Maximum conductor Ø 32 mm CAT III 600 V safety rating Also available with softcase for DMM and clamp (i410 kit) One year warranty Current Clamp DMM Accys
Fluke i400s 400 A Current Clamp Companion to your scope or power quality meter to measure up to 400 A AC. Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating. Specially designed to offer maximum utility in a compact shape. Take accurate current readings without breaking the circuit. Soft non-slippery overmold handle. Optional PM9081/001 BNC/Banana adapter for DMM's. Two ranges: 40 A & 400 A, 10 & 1 mV/Amp output. Max. conductor Ø 32 mm. Current Clamp DMM Accys
Fluke i400 AC Current Clamp with Banana Plug Connections Companion to your DMM to measure up to 400 A AC 1mA/Amp output guarantees easy reading on you meter Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating Specially designed to offer maximum utility in a very compact shape Take accurate current readings without breaking the circuit Soft non-slippery overmold handle prevents from accidental touching live wiring Max. conductor Ø 32 mm Current Clamp DMM Accys
Fluke i310s Current Clamp Current Ranges: 30 A and 300 A ACRMS or DCMeasuring Ranges: ±45 A and 450 A Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A) Resolution: ±50 mA (40 A) to ±100 mA (400 A) Load Impedance: > 10 k Ohms and £ 100 pF Frequency Range (small signal): DC to 20 kHz (- 3 dB) Phase Shift below 1 kHz, < 2 degrees Temperature Coefficient: ±0.1% of reading / ±C Power Supply: 9 V Alkaline Current Clamp DMM Accys
Fluke i3000s Flex 24 AC Current Clamp 610mm (24in.) Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm (7 in.) CAT III 600V safety rating Current Clamp DMM Accys
Fluke i3000s AC Current Clamp An optional accessory for use with Fluke DMMs, PowerMeters and ScopeMeter test tools Measures ac current from 1A to 2400A RMS continuous PM9081/001 BNC to banana adapter included Current Clamp DMM Accys