Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
30A to 3000A
60A to 6000A
Peak current for sinusoidal currents:
10kA
19kA
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamp DMM Accys
|
|
|
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
2A to 200A
10A to 1000A
Peak current for sinusoidal currents:
480A
2700A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 600 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamp DMM Accys
|
|
|
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
1A to 100A
5A to 500A
Peak current for sinusoidal currents:
240A
1350A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamp DMM Accys
|
|
|
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer
|
|
Measuring Range selectable per software 1 A to 100 A 5 A to 500 A
Peak current for sinusoidal currents 240 A 1350 A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening 45 cm length
2 m cable
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamp DMM Accys
|
|
|
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer
|
|
Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A
Peak current for sinusoidal currents74 A 300 A
Intrinsic error 0.5%
Frequency Range 40 Hz to 10 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamp DMM Accys
|
|
|
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer
|
|
Measuring Range selectable per software:0.01A to 1A0.1A to 10A
Peak current for sinusoidal currents:3.7A to 37A
Intrinsic error: 0.5%
Frequency Range: 40Hz to 10kHz
Operating Voltage: 300V CAT IV
Phase Error: 0.5°
Jaw Opening: <15mm diameter or 15x17mm bus bars
Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamp DMM Accys
|
|
|
Fluke i800 AC Current Clamp Probe
|
|
Measures AC current from 100mA to 800 A rms
30 Hz to 10 kHz frequency range
CAT III 600 V rating
Accepts up to 54 mm (2.1 in) diameter conductor size
1000:1 conversion factor for easy calculation
Rugged positive action design
|
Current Clamp DMM Accys
|
|
|
Fluke i6000s Flex-36 AC Current Clamp (36in.)
|
|
The i6000sflex is an AC current probe utilizing the Rogowski principle
It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers
The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas
Current Ranges: 60A/600A/6000A AC RMS
Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A
Frequency Range: 10 Hz to 50 kHz (- 3 dB)
Load Impedance: 100 kOhm minimum
Accuracy (at +25°C): ±1%... |
Current Clamp DMM Accys
|
|
|
Fluke i6000s Flex-24 AC Current Clamp (24in.)
|
|
The i6000sflex is an AC current probe utilizing the Rogowski principle
It can be used to measure currents up to 6000A when used in conjunction with oscilloscopes, recorders or data loggers
The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas
Current Ranges: 60A/600A/6000A AC RMS
Output Sensitivity (AC coupled): 50 mV /5mV / 0.5mV per A
Frequency Range: 10 Hz to 50 kHz (- 3 dB)
Load Impedance: 100 kOhm minimum
Accuracy (at +25°C): ±1%... |
Current Clamp DMM Accys
|
|
|
Fluke i5sPQ3 AC 5A Current Clamp (3 Pack)
|
|
Low level current clamp measures up to 5 A ac
Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches)
Take accurate readings without breakings the circuit
CAT III 600 V (For insulated conductors only)
|
Current Clamp DMM Accys
|
|
|
Fluke i5s AC Current Clamp
|
|
Expand the use of your Fluke 430 series power quality tool with this 5A ac current clamp
Specially configured to provide low current accuracy while taking measurements on secondary current transformers
Low level current clamp measures up to 5A ac
Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 inches)
Take accurate readings without breakings the circuit
CAT III 600 V (For insulated conductors only)
|
Current Clamp DMM Accys
|
|
|
Fluke i430-Flexi-TF-4PK 6000 A Flexible AC Current Probe
|
|
Current Range: 6000 A AC
Frequency Range: 10 Hz to 7 kHz (-3 dB)
Accuracy: +/- 1% of reading (@25 C, 50 Hz)
i430-Flexi-TF works with:
Fluke 434-II Series II Three-Phase Energy Analyzer
Fluke 435-II Series II Three-Phase Power Quality and Energy Analyzer
Fluke 437-II Series II 400 Hz Three-Phase Power Quality and Energy Analyzer
|
Current Clamp DMM Accys
|
|
|
Fluke i430-Flexi-TF 6000 A Flexible AC Current Probe
|
|
Current Range: 6000 A AC
Frequency Range: 10 Hz to 7 kHz (-3 dB)
Accuracy: +/- 1% of reading (@25 C, 50 Hz)
i430-Flexi-TF works with:
Fluke 434-II Series II Three-Phase Energy Analyzer
Fluke 435-II Series II Three-Phase Power Quality and Energy Analyzer
Fluke 437-II Series II 400 Hz Three-Phase Power Quality and Energy Analyzer
|
Current Clamp DMM Accys
|
|
|
Fluke i410-Kit AC/DC Current Clamp and Carry Case Kit
|
|
i410 1-400A AC rms, 1-400A DC Current Clamp
Zippered vinyl carry case with moveable divider
|
Current Clamp DMM Accys
|
|
|
Fluke i410 AC/DC Current Clamp
|
|
Battery-powered Hall-effect probe measures 1A to 400 A
1mV/Amp output guarantees easy reading on your meter
Take accurate current readings without breaking the circuit
Maximum conductor Ø 32 mm
CAT III 600 V safety rating
Also available with softcase for DMM and clamp (i410 kit)
One year warranty
|
Current Clamp DMM Accys
|
|
|
Fluke i400s 400 A Current Clamp
|
|
Companion to your scope or power quality meter to measure up to 400 A AC.
Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating.
Specially designed to offer maximum utility in a compact shape.
Take accurate current readings without breaking the circuit.
Soft non-slippery overmold handle.
Optional PM9081/001 BNC/Banana adapter for DMM's.
Two ranges: 40 A & 400 A, 10 & 1 mV/Amp output.
Max. conductor Ø 32 mm.
|
Current Clamp DMM Accys
|
|
|
Fluke i400 AC Current Clamp with Banana Plug Connections
|
|
Companion to your DMM to measure up to 400 A AC
1mA/Amp output guarantees easy reading on you meter
Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating
Specially designed to offer maximum utility in a very compact shape
Take accurate current readings without breaking the circuit
Soft non-slippery overmold handle prevents from accidental touching live wiring
Max. conductor Ø 32 mm
|
Current Clamp DMM Accys
|
|
|
Fluke i310s Current Clamp
|
|
Current Ranges: 30 A and 300 A ACRMS or DCMeasuring Ranges: ±45 A and 450 A
Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
Resolution: ±50 mA (40 A) to ±100 mA (400 A)
Load Impedance: > 10 k Ohms and £ 100 pF
Frequency Range (small signal): DC to 20 kHz (- 3 dB)
Phase Shift below 1 kHz, < 2 degrees
Temperature Coefficient: ±0.1% of reading / ±C
Power Supply: 9 V Alkaline
|
Current Clamp DMM Accys
|
|
|
Fluke i3000s Flex 24 AC Current Clamp 610mm (24in.)
|
|
Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output
Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
Maximum conductor diameter 178 mm (7 in.)
CAT III 600V safety rating
|
Current Clamp DMM Accys
|
|
|
Fluke i3000s AC Current Clamp
|
|
An optional accessory for use with Fluke DMMs, PowerMeters and ScopeMeter test tools
Measures ac current from 1A to 2400A RMS continuous
PM9081/001 BNC to banana adapter included
|
Current Clamp DMM Accys
|
|