Accessories

  • Filter
  Name SKU Description Category
Fluke 90i-610s 1A to 600A AC/DC Current Probe Current Range: 1 to 600 A DC or AC Peak Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A) Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A Frequency Range: 40 Hz to 400 Hz Working Voltage: 600 V AC rms Maximum Conductor Diameter: 34 mm (1.34 inch) Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V Automotive Accessories
Fluke BP880 BNC to Female Double Stacking Banana Plug Allows for hands-free testing in controlled voltage environments 500 VRMS maximum Banana plug is nickel-plated, beryllium copper for low contact resistance The BNC shell is plated for tarnish resistance Operating temperature +50 °C (+122 °F) maximum Automotive Accessories
Fluke BP881 BNC to Male Double Stacking Banana Plug Allows for hands-free testing in controlled voltage environments 500 VRMS maximum Banana plug is nickel-plated, beryllium copper for low contact resistance The BNC shell is plated for tarnish resistance Operating temperature +50 °C (+122 °F) maximum Automotive Accessories
Fluke PV350 Pressure Vacuum Module Compatible with all Fluke and most popular DMMs Digital pressure and vacuum measurements in a single module Transducer sealed in 316 stainless steel compatible with variety of liquids and gases Measures vacuum to 76 cm Hg Displays results in English (psig of Hg) or metric (kPa or cm Hg) units  Measures pressure to 3447 kPa (500 psig) One year warranty Automotive Accessories
Fluke RPM80 Inductive Pick-Up/External Trigger Provides RPM readings Automotive Accessories
Fluke TL28A Automotive Test Lead Set Large jaws, long leads and a piercing probe Solid, spring-loaded copper clips with a wide 12.7 mm (.50") jaw opening and serrated teeth Large piercing needle for penetrating larger gauge wires 1.5 m (60"), silicone-insulated leads, useable from -80 °C to +150 °C (-112 °F to +302 °F) Rated for 30 V, 10 A. One red, one black Flexible silicone insulated leads are heat and cold resistant Cat I 30 V, 10 A Automotive Accessories
Fluke TL82 Automotive Pin & Socket Adapter Set Retractable shrouded test leads Complete set of 8 pin-and-socket adapters with flexible tips One red and one black in the following sizes: Size 22 contact 0.030 in (0.76 mm) rated 5 A Size 20 contact 0.040 in. (1.02 mm) rated 7.5A Size 16 contact 0.063 in. (1.60 mm) rated 13 Tested to 60 V DC Size 12 contact 0.093 in. (2.36 mm) rated 23 Automotive Accessories
Fluke TLK281 SureGrip™ Automotive Test Lead Kit Includes: TP81 Insulation Piercing Clip Set TL224 Suregrip™ Silicone Test Lead Set TP220 Suregrip™ Test Probe Set AC220 Suregrip™ Alligator Clip Set AC285 Suregrip™ Large Jaw Alligator Clip Set Soft Case Automotive Accessories
Fluke TLK282 SureGrip™ Deluxe Automotive Test Lead Kit Includes: TP81 Insulation Piercing Clip Set TP40 Automotive Back Probe Pins (five) TL224 Suregrip™ Silicone Test Lead Set TP220 Suregrip™ Test Probe Set AC220 Suregrip™ Alligator Clip Set AC285 Suregrip™ Large Jaw Alligator Clip Set AC280 Suregrip™ Hook Clip Set Soft Case Automotive Accessories
Fluke TP40 Automotive Back Probe Pins (five) Banana jack accepts all DMM and banana jack leads Tested to 60 V DC Automotive Accessories
Fluke TP81 Insulation Piercing Clip Set Banana jack accepts all DMM and banana jack leads Non-rotating banana jack prevents leads from tangling, allowing you to tighten/loosen clamp while still connected to the test lead For use with test leads with 4 mm banana plugs Tested to 60 V DC Automotive Accessories
Fluke TP82 Insulation Piercing Clip Set Banana jack accepts all DMM and banana jack leads Non-rotating banana jack prevents leads from tangling, allowing you to tighten/loosen clamp while still connected to the test lead For use with test leads with 2 mm probes Tested to 60 V DC Automotive Accessories
Fluke TP88 Rigid Back Probe Pins Slides onto test probes measuring 2 mm (0.08 inches) Tested to 60 V DC Automotive Accessories
Fluke BP120MH Rechargeable Ni-Cad Battery Pack Nominal Voltage: 4.8V Capacity: 1800 mAh Batteries, Charges and Adapters
Fluke BP189 High Capacity Battery Pack for Fluke 180 Series DMM Attach this battery pack to your Fluke 189 to use 4 ‘C’ cell batteries instead of the ‘AA’ cell batteries CAT III 1000 V, CAT IV 600 V One Year Warranty Batteries and meter sold separately Batteries, Charges and Adapters
Fluke BP190 Ni-MH Battery Pack Nominal Voltage: 7.2V Capacity: 3,500 mAh Batteries, Charges and Adapters
Fluke BP7235 Ni-MH Battery Pack 7.2V 3500 mA-hour rechargeable Ni-MH battery pack Provides typical 16-hour battery life when used in 700 or 740 Calibrator Material: Six 1.2V dc Ni-MH cells in custom-molded ABS/PC-blend case Dimensions: 7.1" x 2.2" x .9" (150 mm x 56 mm x 22 mm) Weight: 11 oz/310g One year warranty Batteries, Charges and Adapters
Fluke TISBP IR Smart Battery Pack Rechargeable Battery for the Ti40/50 Series Thermal Imagers Replacement battery pack for FlexCam - single battery pack for additional time in the field or replacement Batteries, Charges and Adapters
Fluke BC190 Line Voltage Adapter/Battery Charger Mains (Line Voltage)   - BC190/801 (Europe) 230V ± 10%   - BC190/803 (North America) 120V ± 10%   - BC190/804 (United Kingdom) 230V ± 10%   - BC190/806 (Japan) 100V ± 10%   - BC190/807 (Australia) 230V ± 10%   - BC190/808 (Universal) switchable 115V± 15% or 230V ± 15%   - 808 are equipped with a male receptacle plug that must be     connected to a line cord appropriate for local use. (Line cord     not included) Batteries, Charges and Adapters
Fluke BC190 Line Voltage Adapter/Battery Charger Mains (Line Voltage)   - BC190/801 (Europe) 230V ± 10%   - BC190/803 (North America) 120V ± 10%   - BC190/804 (United Kingdom) 230V ± 10%   - BC190/806 (Japan) 100V ± 10%   - BC190/807 (Australia) 230V ± 10%   - BC190/808 (Universal) switchable 115V± 15% or 230V ± 15%   - 808 are equipped with a male receptacle plug that must be     connected to a line cord appropriate for local use. (Line cord     not included) Batteries, Charges and Adapters