Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer
|
|
Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A
Peak current for sinusoidal currents74 A 300 A
Intrinsic error 0.5%
Frequency Range 40 Hz to 10 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamps
|
|
|
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer
|
|
Measuring Range selectable per software 1 A to 100 A 5 A to 500 A
Peak current for sinusoidal currents 240 A 1350 A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening 45 cm length
2 m cable
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamp DMM Accys
|
|
|
Fluke 700LTP-1 Low-pressure Test Pump
|
|
Pump can be easily cleaned without disassembly.
Adjustable pressure relief valve with slow-bleed capability.
Allows the slow release pressure at a controlled rate
Quick fit connectors, one for the reference port for connection to a Fluke 700 series pressure module and one to connect to a unit under test
Slim design, easy to carry and use
Includes:
(2) adapters to convert the reference and UUT port hose fitting to 1/4" BSP female
Adapter to convert the reference port hose... |
Pressure
|
|
|
Fluke AC283 Pincer Clips
|
|
One pair (red, black) of nickel plated pincers open to 5 mm 11.4 cm flexible insulated shaft
Recommended for use with TL222 and TL224 test leads
CAT IV 600 V, CAT III 1000 V, 1 A rating. UL listed
One year warranty
|
Test Leads, Probes, Clips
|
|
|
Kyoritsu 7196A
|
|
Applicablemodel
6016
•
Test leads with remote control switch
•
1,550mm
|
Test Leads
|
|
|
Temp101A Data Logger
|
|
The Temp101A is one of MadgeTech’s newest data loggers. It is part of a new series of low cost, state-of-the-art data loggers. MadgeTech has taken the lead in offering the most advanced, low cost, battery powered data loggers in the world today.
The Temp101A offers a 10 year battery life, a multiple start/stop function, ultra-high speed download capability, 1 million reading storage capacity, optional memory wrap, battery life indicator, optional password protection, programmable high-low... |
Temperature
|
|
|
Fluke H80M Protective Holster with Magnetic Hanging Strap
|
|
Set Includes:
Yellow protective holster for all 80 series DMM's (new as well as old)
General purpose hanger
Hook and loop straps
Hanging magnet
|
Cases and Holsters
|
|
|
Megger BD-59090 MOM2 MicroOhmmeter
|
|
Up to 220 A
Battery powered
Lightweight – 1 kg
Safe test – DualGround
Auto range: 1 μΩ to 1000 mΩ
Bluetooth PC communication
Complies with IEEE and IEC standards
Easy to use – Attach the Kelvin Clamps and press TEST button.
Active-duty and rugged design. All weather, all environment, all industry usage.
Truly handheld
Testing with both sides grounded
|
Megger
|
|
|
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer
|
|
Measuring Range selectable per software 1 A to 100 A 5 A to 500 A
Peak current for sinusoidal currents 240 A 1350 A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening 45 cm length
2 m cable
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamps
|
|
|
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
1A to 100A
5A to 500A
Peak current for sinusoidal currents:
240A
1350A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamp DMM Accys
|
|
|
Fluke 700PRV-1 Pressure Relief Valve Kit
|
|
Adjustable from 725 to 5800 PSI (50 to 200 bar)
Preset at 2,900 psi/200 bar)
Repeatability to 10% of nominal setting.
Installs directly into the 700HTP-1 pump
|
Pressure
|
|
|
Fluke AC285 Aligator Clips
|
|
One pair (red, black) of large alligator clips with nickel-plated steel jaws
Multi-purpose tooth pattern grips anything from fine gauge wire to a 20 mm bolt
Recommended for use with TL222 and TL224 test leads
CAT IV 600 V; CAT III 1000 V, 10 A rating
One year warranty
|
Test Leads, Probes, Clips
|
|
|
Kyoritsu 7197
|
|
Applicablemodels
8325F
*
Cannot be used for MODLE 8309 of new type.
The difference between the new type and the old type is as per the following diagram.
old type
new type
•
Small Clips adaptor
•
650mm
•
Adaptor to convert the crocodile clips of the voltage sensor (8309)... |
Test Leads
|
|
|
TempRetriever Data Logger
|
|
The TempRetriever is a low cost, reusable temperature data logger which allows for a myriad of applications. The device excels in dry applications such as shipping, museums, R&D, warehouses and HVAC. It boasts an accuracy of ±0.5ºC and a resolution of 0.1ºC. The TempRetriever can store up to 16,383 readings in its non-volatile memory and, coupled with up to a one year battery life and LED alarm indication makes this the perfect temperature data logger when keeping costs down is... |
Temperature
|
|
|
Fluke TPAK ToolPak, Meter Hanging Kit
|
|
Kit includes: 9 inch hook and loop strap, universal hanger clip, hook hanger for non magnetic surfaces and a strong magnet.
Solves almost any hanging and positioning problem you may face.
The universal hanger allows you to hang your meter on nails, hooks and many other objects.
Compatible with many Fluke instruments.
One year warranty.
|
Cases and Holsters
|
|
|
Megger BD-59092 MOM2 MicroOhmmeter
|
|
Up to 220 A
Battery powered
Lightweight – 1 kg
Safe test – DualGround
Auto range: 1 μΩ to 1000 mΩ
Bluetooth PC communication
Complies with IEEE and IEC standards
Easy to use – Attach the Kelvin Clamps and press TEST button.
Active-duty and rugged design. All weather, all environment, all industry usage.
Truly handheld
Testing with both sides grounded
|
Megger
|
|
|
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
1A to 100A
5A to 500A
Peak current for sinusoidal currents:
240A
1350A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamps
|
|
|
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder
|
|
Measuring Range selectable per software:
2A to 200A
10A to 1000A
Peak current for sinusoidal currents:
480A
2700A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 600 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamp DMM Accys
|
|
|
Fluke 700PTP-1 Pneumatic Test Pump
|
|
Pump can be easily cleaned without disassembly
The vernier can be used as a stand-alone low pressure calibration source
Two pressure ports allowing simultaneous connection
¼ -NPT female fitting for the reference gauge or pressure module
¼” NPT female fitting for the unit under test
Adjustable stroke length can be set to limit the pressure per stroke
Includes
1/4 in NPT male to 1/4 in BSP female
1 meter of hose
(2) 1/8 in NPT male quick connects
1/8 NPT female to 1/4 in... |
Pressure
|
|
|
Fluke AC285-FTP Alligator Clips and Adaptors for FTP-1 and FTPL-1
|
|
Alligator Clips and Adaptors
For FTP-1 and FTPL-1 Fused Test Probes
|
Test Leads, Probes, Clips
|
|