DKK-TOA MDM-137A (2-wire)
|
|
Electromagnetic Concentration Transmitter MDM-137A (2-wire)
Electromagnetic concentration analyzer for field installation in a compact and rigid aluminum enclosure
Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%)data automatically
Assignable measurement range
Examples of measurement ranges
NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15%
|
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA AQM-210A
|
|
Panel Type Resistivity Analyzer AQM-210A
Compact DIN 96 size
Best suited for water quality control in ultra-pure water production lines
Two detectors connectable
RS-232 equipped as standard specification
Output: 2-channel, insulated, 4 - 20mA
Meas. range
0.00 - 20.00 MΩ・cm
|
Panel Type Resistivity Analyzer for Ultra-Pure Water
|
|
|
DKK-TOA JOC-711C / JOC-950C
|
|
Detector with Water Jet Cleaner JOC-711C / JOC-950C
Cleaning electrode contamination by jetting water or air onto the electrode
Immersion type (JOC-711C) and drop-in type (JOC-950C)
Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)
|
Immersion/Drop-in Type DO Holder/Detector with Water Jet Cleaner
|
|
|
DKK-TOA MBM-102A
|
|
Panel Type Electromagnetic Concentration Analyzer MBM-102A
Compact DIN 96 size
Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%) data automatically
Assignable measurement range
2-point contact signal, 4 - 20mA output (RS-232 optional)
Examples of measurement ranges
NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15% |
Panel Type Electromagnetic Conductivity/Concentration Analyzer
|
|
|
DKK-TOA WBM-210A
|
|
Compact DIN 96 size
Conductivity meter with built-in microcomputer for various applications such as ultra-pure water production, boiler plants, foodstuff plants, etc.
Two detectors connectable
RS-232 equipped as standard specification
Output: 2-channel, insulated, 4 - 20mA
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm
|
Panel Type Conductivity Analyzer
|
|
|
DKK-TOA OBM-300 (4-wire)
|
|
Low-Concentration DO Transmitter OBM-300 (4-wire)
Multi-functional low-concentration DO analyzer for field installation in a compact diecast aluminum case
3 ranges (automatically switched), 2-point regulated output
Alterable output range
One-touch calibration and various self-diagnostic functions
Meas. range
Minimum : 0 - 20 μg/L Maximum: 0 - 999.9 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA ME-100 series (compact and lightweight leadless type)
|
|
Compact toroidal, heat resistant PVC type or Teflon detector with excellent corrosion resistance are available
Accurate results for high conductivity corrosive solutions (such as strong acid/alkali)
Types of detectors available: flow-through, immersion, pipeline insertion, drop-in, etc.
Meas. range
Minimum : 0 - 500 μS/cm Maximum: 0 - 2000 mS/cm
|
Electromagnetic Conductivity Detector
|
|
|
DKK-TOA PSS/ASS‐304B(KCl replenish-free) / PSS/ASS‐314B(KCl refillable)
|
|
Exchangeable Tip ORP Electrode PSS/ASS‐304B(KCl replenish-free) / PSS/ASS‐314B(KCl refillable)
asy-to-replace electrode tip and reference electrode junction tip
Platinum electrodes (PSS) and gold electrodes (ASS) available
KCl non-refillable type is ideal for wastewater treatment; KCl refillable type for processes
Selection of electrode holder: immersion type, drop-in type and flow-through type
Meas. range
ORP: -2000 - +2000 mV |
Exchangeable Tip pH Electrode
|
|
|
DKK-TOA CD-36D/38D
|
|
Measures free residual chlorine of chlorinated samples from purification/food processing/semiconductor plants and pool without reagent
Continuous measurement by polarographic method
Meas. range
CD-36D: 0 - 2 mg/L (ppm) CD-38D: 0 - 100 mg/L (ppm)
|
Reagentless Free Chlorine Analyzer
|
|
|
DKK-TOA AR4/AR5 Series
|
|
Compact 2-electrode type (titanium) detector designed for ultrapure water
Pipeline insertion type, leadless type
Two types of cell constants available: 0.01, 0.1 cm-1
Meas. range
0 - 20/200 MΩ·cm 0 - 0.2/2 μS/cm
|
Industrial Conductivity Detector
|
|
|
DKK-TOA TUH-1600
|
|
High Sensitivity Turbidity Analyzer TUH-1600
Highly-sensitive turbidity analyzer suitable for water purification process
Surface scattering light method employed; 1 range/2 ranges/3 ranges available
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 0.2 to 0 - 2.0 (1 - 3 ranges) (NTU)
|
Turbidity Analyzer
|
|
|
DKK-TOA UHC-7C / UHC-8C
|
|
Flow-Through Type Detector with Ultrasonic Cleaner UHC-7C / UHC-8C
Detectors composed of holder and ultrasonic cleaner: Immersion type (UHC-7C) and flow-through type (UHC-8C)
One-touch detachable holder enables quick calibration and easy maintenance
Compatible with GSS series
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA SSF-1600
|
|
Continuous optical measurements of SS and MLSS by using infrared scattering method
Safe and simple maintenance attainable with the small, lightweight stainless detector
Meas. range
0 - 1000/3000 mg/L 0 - 10000/20000/30000 mg/L (2-ranges or 3-ranges)
|
Suspended Solids Concentration Analyzer
|
|
|
DKK-TOA SCA-200
|
|
Designed for oil refinery
Batch and continuous measurement of sulfur concentration of petroleum products like light and heavy oil
Best suited for product and quality control of petroleum products
Eliminates RI regulation process and enhances safety by using the compact and X-ray tube
Meas. range
0~0.1 wt% 0~5 wt%
|
Process Sulfur Content Analyzer
|
|
|
DKK-TOA PAC‐R7
|
|
pH Meter with Chemical Cleaner PAC‐R7
Easy installation as equipments are previously set on the hold stand
Designed for long-term, continuous and highly reliable pH measurement in wastewater treatment facilities
Including mounting brackets
Meas. range
pH: -1 - 15 -5 - 100℃
|
pH Meter with Auto-Calibration/Chemical Cleaner
|
|
|
DKK-TOA U-32 / U-42(Explosion proof type)
|
|
Controller (For Oil Refineries) U-32 / U-42(Explosion proof type)
Intelligent controller best suited for use with FPA, PPA and CPA
Applicable to multi-stream system, interactive data entry via display & automatic calibration
Auto-calibration, self-diagnostic, remote control, communication function equipped
|
Controller
|
|
|
DKK-TOA HBM-165H(2-wire)
|
|
pH / ORP Transmitter with HART Interface HBM-165H(2-wire)
HART communication protocol interface with a 2-wire, 24 VDC circuit
Available for both pH and ORP measurements
Diecast aluminum enclosure, digital display and a wide range of other useful features
One-touch auto calibration
Self-diagnostic function
Meas. range
-1.00 - 15.00 ORP -2000 - 2000 mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA WBM-165H (2-wire)
|
|
Conductivity Transmitter with HART Interface WBM-165H (2-wire)
HART communication protocol interface with a 2-wire, 24 VDC circuit
Aluminum diecast enclosure, digital display and a wide range of other useful features
One-touch auto calibration
Self-diagnostic function
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm
|
Transmitter for Industrial Conductivity Analyzer
|
|
|
DKK-TOA MBM-160(4-wire)
|
|
Electromagnetic Conductivity Transmitter MBM-160(4-wire)
Electromagnetic conductivity analyzer for field installation in a compact aluminum diecast enclosure
Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali)
2-point contact signal, 2-channel output including temperature (RS-232 optional)
Power source: 90 - 264VAC, 50/60Hz
Meas. range
Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm |
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA WBM-121A / AK Cell
|
|
Sanitary Type Conductivity Analyzer/Detector WBM-121A / AK Cell
Compact DIN 96 size
Designed for sanitary conductivity analyzer for the food industry
Applied in foodstuff plants and installed in pipes and tanks. Best suited for CIP (stationary cleaning) management, debubbling agent control and liquid level management
Meas. range
0 - 300/3000 μS/cm (at 25 degrees C) 0 - 20/200 mS/cm (at 25 degrees C)
|
Panel Type Conductivity Analyzer
|
|