DKK-TOA MDM-135A (2-wire)
|
|
Electromagnetic Conductivity Transmitter MDM-135A (2-wire)
Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum enclosure
Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali)
Alterable output range
Meas. range
Minimum : 0 - 2 mS/cm Maximum : 0 - 2000 mS/cm
|
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA MDM-137A (2-wire)
|
|
Electromagnetic Concentration Transmitter MDM-137A (2-wire)
Electromagnetic concentration analyzer for field installation in a compact and rigid aluminum enclosure
Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%)data automatically
Assignable measurement range
Examples of measurement ranges
NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15%
|
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA ME-100 series (compact and lightweight leadless type)
|
|
Compact toroidal, heat resistant PVC type or Teflon detector with excellent corrosion resistance are available
Accurate results for high conductivity corrosive solutions (such as strong acid/alkali)
Types of detectors available: flow-through, immersion, pipeline insertion, drop-in, etc.
Meas. range
Minimum : 0 - 500 μS/cm Maximum: 0 - 2000 mS/cm
|
Electromagnetic Conductivity Detector
|
|
|
DKK-TOA ME-6/7/11T series (high sensitivity type)
|
|
Toroidal type teflon detector with excellent corrosion/heat/pressure resistance
Accurate results for high conductivity corrosive solutions (such as strong acid/alkali)
Types of detectors available: flow-through, immersion, pipeline insertion, etc.
Meas. range
Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm
|
Electromagnetic Conductivity Detector
|
|
|
DKK-TOA MWB4-70
|
|
B4 size compact analyzer excellent in reliability, durability and maintainability
Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents
Equipped with interactive easy-to-use color touch panel
|
Automatic Water Quality Analyzer for City Water
|
|
|
DKK-TOA OBM-100H
|
|
Panel Type Low-Concentration DO Transmitter OBM-100H
Panel type low-concentration DO analyzer in a compact DIN 96 size
2-point regulated, 4 - 20mA, RS-232 output
One-touch calibration and various self-diagnostic functions
Power supply: 90~264VAC, 50/60Hz
Meas. range
Minimum : 0 - 20 μg/L Maximum: 0 - 1000 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA OBM-102A
|
|
Panel type DO analyzer in a compact DIN 96 size
One-touch calibration and various self-diagnostic functions
2-point contacts signal, 4 - 20mA output (RS-232 optional)
Power supply: 90 - 264VAC, 50/60Hz
Meas. range
Minimum : 0 - 1 mg/L Maximum: 0 - 50 mg/L
|
Panel Type DO Analyzer
|
|
|
DKK-TOA OBM-300 (4-wire)
|
|
Low-Concentration DO Transmitter OBM-300 (4-wire)
Multi-functional low-concentration DO analyzer for field installation in a compact diecast aluminum case
3 ranges (automatically switched), 2-point regulated output
Alterable output range
One-touch calibration and various self-diagnostic functions
Meas. range
Minimum : 0 - 20 μg/L Maximum: 0 - 999.9 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA OC-64
|
|
Low-Concentration DO Detector for Pure Water OC-64
Suitable for low-concentration DO measurement (pure water in semiconductor factories, boiler water in power plants)
Micro-flow (100mL/min) with special flow cell
Electrode: polarograph type 7561L (Ag electrode) or 7563L (Au electrode)
Lead wire: ELW-32
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA OC-711 / OC-950
|
|
Immersion/Drop-In Type DO Holder OC-711 / OC-950
Lightweight PVC holder; length of immersion type holder: 0.3 - 3.5 m, length of stainless steel protection pipe for drop-in type holder: 2 - 6 m
Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)
|
Immersion/Drop-in Type DO Holder/Detector with Water Jet Cleaner
|
|
|
DKK-TOA ODM-100A (2-wire) / ODM-110A (4-wire)
|
|
Industrial Low-Concentration DO Transmitter ODM-100A (2-wire) / ODM-110A (4-wire)
Easy-to-use low-concentration DO analyzer for field installation in a compact and rigid aluminum case
Simplified calibration procedure; auto detection of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
Minimum: 0 - 20 μg/L Maximum: 0 - 2000 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA PAC‐R7
|
|
pH Meter with Chemical Cleaner PAC‐R7
Easy installation as equipments are previously set on the hold stand
Designed for long-term, continuous and highly reliable pH measurement in wastewater treatment facilities
Including mounting brackets
Meas. range
pH: -1 - 15 -5 - 100℃
|
pH Meter with Auto-Calibration/Chemical Cleaner
|
|
|
DKK-TOA PHC-7D
|
|
Immersion Type Sensor with Pulse Air Jet Cleaner PHC-7D
Immersion type pH/ORP electrode holder combined with pulse air jet cleaner
Cleaning by high-speed water stream created by the rapid expansion of pulse-jetted compressed air in the sample water
High cleaning effect due to air bubbles present in the water stream randomly hitting the electrode
No consumables required, such as reagents, brushes
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA PPA
|
|
Designed for oil refinery
Continuous measurement of pour point which is used as indication of light oil and intermediate fraction of fuel oil A
Best suited for management of plant and product control
Explosion-proof TIIS d2G4 certified
Meas. range
-30 - +20 degrees C
|
Pour Point Analyzer
|
|
|
DKK-TOA PSS/ASS‐304B(KCl replenish-free) / PSS/ASS‐314B(KCl refillable)
|
|
Exchangeable Tip ORP Electrode PSS/ASS‐304B(KCl replenish-free) / PSS/ASS‐314B(KCl refillable)
asy-to-replace electrode tip and reference electrode junction tip
Platinum electrodes (PSS) and gold electrodes (ASS) available
KCl non-refillable type is ideal for wastewater treatment; KCl refillable type for processes
Selection of electrode holder: immersion type, drop-in type and flow-through type
Meas. range
ORP: -2000 - +2000 mV |
Exchangeable Tip pH Electrode
|
|
|
DKK-TOA RHC-7C / RHC-7EC
|
|
Immersion Type Detector with Chemical Cleaner RHC-7C / RHC-7EC
Immersion type electrode holder combined with chemical cleaning system
By spraying mixed air&cleaning agents onto the electrode tip it dissolves fouling away
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA SCA-200
|
|
Designed for oil refinery
Batch and continuous measurement of sulfur concentration of petroleum products like light and heavy oil
Best suited for product and quality control of petroleum products
Eliminates RI regulation process and enhances safety by using the compact and X-ray tube
Meas. range
0~0.1 wt% 0~5 wt%
|
Process Sulfur Content Analyzer
|
|
|
DKK-TOA SCU-02
|
|
Adopts environmental friendly Freon replacement gas
Automatic temperature adjustment
Safety apparatus equipped such as overload relay and current overload breaker
Explosion-proof TIIS ExpdⅡBT4 certified
|
Explosion-Proof Type Cooler
|
|
|
DKK-TOA SHBM-161 / 163 (2-wire)
|
|
Compact diecast aluminum enclosure
ExiallCT4 (combined with a Zener Barrier) explosion-proof and IP65 conformed enclosure
Easy calibration done with standard solution
Auto-detection of electrodes deterioration
Alterable output range
Meas. range
SHBM-161: pH; -1 - 15 SHBM-163: ORP; -2000 - +2000 mV
|
Intrinsically Safe Explosion-Proof Type Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA SOD-35D (2-Wire Transmitter) SOC-71 (Sensor)
|
|
Polarograph type DO analyzer with intrinsically safe explosion-proof function (combined with a Zener Barrier)
Alterable output range
Types of detectors available: immersion, flow-through and fermentation-used (electrodes: ELD-017/ELD-019)
Meas. range
Minimum : 0 - 1 mg/L Maximum: 0 - 20 mg/L
|
Intrinsically Safe Explosion-Proof Type DO Transmitter
|
|