DKK-TOA SSF-1600
|
|
Continuous optical measurements of SS and MLSS by using infrared scattering method
Safe and simple maintenance attainable with the small, lightweight stainless detector
Meas. range
0 - 1000/3000 mg/L 0 - 10000/20000/30000 mg/L (2-ranges or 3-ranges)
|
Suspended Solids Concentration Analyzer
|
|
|
DKK-TOA SCA-200
|
|
Designed for oil refinery
Batch and continuous measurement of sulfur concentration of petroleum products like light and heavy oil
Best suited for product and quality control of petroleum products
Eliminates RI regulation process and enhances safety by using the compact and X-ray tube
Meas. range
0~0.1 wt% 0~5 wt%
|
Process Sulfur Content Analyzer
|
|
|
DKK-TOA PAC‐R7
|
|
pH Meter with Chemical Cleaner PAC‐R7
Easy installation as equipments are previously set on the hold stand
Designed for long-term, continuous and highly reliable pH measurement in wastewater treatment facilities
Including mounting brackets
Meas. range
pH: -1 - 15 -5 - 100℃
|
pH Meter with Auto-Calibration/Chemical Cleaner
|
|
|
DKK-TOA U-32 / U-42(Explosion proof type)
|
|
Controller (For Oil Refineries) U-32 / U-42(Explosion proof type)
Intelligent controller best suited for use with FPA, PPA and CPA
Applicable to multi-stream system, interactive data entry via display & automatic calibration
Auto-calibration, self-diagnostic, remote control, communication function equipped
|
Controller
|
|
|
DKK-TOA HBM-165H(2-wire)
|
|
pH / ORP Transmitter with HART Interface HBM-165H(2-wire)
HART communication protocol interface with a 2-wire, 24 VDC circuit
Available for both pH and ORP measurements
Diecast aluminum enclosure, digital display and a wide range of other useful features
One-touch auto calibration
Self-diagnostic function
Meas. range
-1.00 - 15.00 ORP -2000 - 2000 mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA WBM-165H (2-wire)
|
|
Conductivity Transmitter with HART Interface WBM-165H (2-wire)
HART communication protocol interface with a 2-wire, 24 VDC circuit
Aluminum diecast enclosure, digital display and a wide range of other useful features
One-touch auto calibration
Self-diagnostic function
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm
|
Transmitter for Industrial Conductivity Analyzer
|
|
|
DKK-TOA MBM-160(4-wire)
|
|
Electromagnetic Conductivity Transmitter MBM-160(4-wire)
Electromagnetic conductivity analyzer for field installation in a compact aluminum diecast enclosure
Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali)
2-point contact signal, 2-channel output including temperature (RS-232 optional)
Power source: 90 - 264VAC, 50/60Hz
Meas. range
Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm |
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA WBM-121A / AK Cell
|
|
Sanitary Type Conductivity Analyzer/Detector WBM-121A / AK Cell
Compact DIN 96 size
Designed for sanitary conductivity analyzer for the food industry
Applied in foodstuff plants and installed in pipes and tanks. Best suited for CIP (stationary cleaning) management, debubbling agent control and liquid level management
Meas. range
0 - 300/3000 μS/cm (at 25 degrees C) 0 - 20/200 mS/cm (at 25 degrees C)
|
Panel Type Conductivity Analyzer
|
|
|
DKK-TOA OBM-100H
|
|
Panel Type Low-Concentration DO Transmitter OBM-100H
Panel type low-concentration DO analyzer in a compact DIN 96 size
2-point regulated, 4 - 20mA, RS-232 output
One-touch calibration and various self-diagnostic functions
Power supply: 90~264VAC, 50/60Hz
Meas. range
Minimum : 0 - 20 μg/L Maximum: 0 - 1000 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA CLF-120
|
|
Reagentless Residual Chlorine Analyzer CLF-120
Measures total residual chlorine of drainage water without reagent
Continuous measurement by polarographic method
Meas. range
0 - 0.5/1.0, 0 - 1/2, 0 - 2/3 mg/L (ppm)
|
Reagentless Free Chlorine Analyzer
|
|
|
DKK-TOA TUI-100
|
|
Turbidity Meter with Integrating Sphere TUI-100
Integrating sphere system employed for lab turbidity measurements
Continuous measurement of turbidity in tap water, river water, industrial water, etc.
Accurate results for minimized influence of color
Meas. range
0 - 0.5/5 to 0 - 100/1000 Cell length: 50mm or 10mm (selectable) (mg/L, ppm, FTU, NTU)
|
Turbidity Analyzer
|
|
|
DKK-TOA JHC-7C/JHC-8C
|
|
Immersion Type Detector with Water Jet Cleaner JHC-7C/JHC-8C
Detectors composed of holder and water-jet cleaner: Immersion type(JHC-7C) and flow-through type(JHC-8C)
By spraying water onto the tip of electrode, the water pressure washes fouling away
One-touch detachable holder and easy maintenance
Simple installation with a sensor, timer&electromagnetic valve integrated unit
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA MBM-162 (4-wire)
|
|
Electromagnetic Concentration Transmitter MBM-162 (4-wire)
Electromagnetic concentration analyzer for field installation in a compact aluminum diecast enclosure
Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%) data automatically
2-point contact signal, 2-channel output including temperature (RS-232 optional)
Examples of measurement ranges
NaCl: 0~10% HCl: 30~40% H2SO4: 93~99.5% NaOH: 0~15%
|
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA HBM-160/HBM-162(4-wire)
|
|
Industrial pH/ORP Transmitter HBM-160/HBM-162(4-wire)
Multi-function pH/ORP analyzer for field installation in a compact aluminum diecast enclosure
One-touch calibration and various self-diagnostic functions
2-point contact signal and 2-channel output including temperature (RS-232 optional)
Power supply: AC90~264V, 50/60Hz
Meas. range
pH meter (HBM-160) : pH -1 - 15 ORP meter (HBM-162) : ORP -2000 - +2000mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA CLBM-50
|
|
Residual Chlorine Analyzer CLBM-50
Ultracompact DIN 48 size
Reagenless model
Auto-cleaning by polishing beads and micro-vibrating electrode
Power supply: 100 - 230VAC
Low power consumption of 5VA
Meas. range
0 - 3 mg/L
|
Reagentless Free Chlorine Analyzer
|
|
|
DKK-TOA OC-64
|
|
Low-Concentration DO Detector for Pure Water OC-64
Suitable for low-concentration DO measurement (pure water in semiconductor factories, boiler water in power plants)
Micro-flow (100mL/min) with special flow cell
Electrode: polarograph type 7561L (Ag electrode) or 7563L (Au electrode)
Lead wire: ELW-32
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA COL-110
|
|
Colorimeter/Turbidity Meter COL-110
Color and turbidity can be measured simultaneously by dual wavelength with just one meter
Equipped with interactive easy-to-use colortouch panel
Meas. range
Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm)
|
Turbidity Analyzer
|
|
|
DKK-TOA BHC-7C
|
|
Immersion Type pH/ORP Detector with Brush Cleaner BHC-7C
Immersion type pH/ORP electrode holder with cleaning brush (BHC-7C)
The swing movements wash the electrode tip and prevent it from fouling
One-touch detachable holder and easy maintenance
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|
|
DKK-TOA HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
|
|
Immersion Type Holder for Replaceable Tip Electrode HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
HC-G70: Transparent PVC holder (heat resistance: 60 degrees C) and semi-transparent PP holder (heat resistance: 80 degrees C) available
HC-G72: SUS316 holder (heat resistance: 80 degrees C)
Length: 0.5 - 3.0m
KCl refillable type stores KCl inside the holder
Mounting bracket/flange available
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA RHC-7C / RHC-7EC
|
|
Immersion Type Detector with Chemical Cleaner RHC-7C / RHC-7EC
Immersion type electrode holder combined with chemical cleaning system
By spraying mixed air&cleaning agents onto the electrode tip it dissolves fouling away
|
Immersion Type pH/ORP Detector with Some Cleaners
|
|