DKK-TOA MAC-355
|
|
pH Meter with Auto Calibration MAC-355
Automatic cleaning and 2-point calibration functions serve long-term reliable pH measurement with just little maintenance
Lift-up type design incorporated with air jet cleaning allows for superior cleaning effect and stable measurement
Self-diagnosis and useful message display
Meas. range
pH: -1 - 15
|
pH Meter with Auto-Calibration/Chemical Cleaner
|
|
|
DKK-TOA SHBM-161 / 163 (2-wire)
|
|
Compact diecast aluminum enclosure
ExiallCT4 (combined with a Zener Barrier) explosion-proof and IP65 conformed enclosure
Easy calibration done with standard solution
Auto-detection of electrodes deterioration
Alterable output range
Meas. range
SHBM-161: pH; -1 - 15 SHBM-163: ORP; -2000 - +2000 mV
|
Intrinsically Safe Explosion-Proof Type Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA ELP-005/006/007 ELP-045/046/047/048
|
|
Suitable for bio-process tanks (fermentation tanks). KCl non-refillable and leadless type. Steam sterilizable, strong glass membrane, lead-free safe design
Two types available: Liquid junctions of both pressurized gel type products (ELP-005/006/007) and double junction type products (ELP-045/046/047/048)
Various electrode lengths available according to various tank sizes
Meas. range
pH: 0 - 14
|
pH Sensor for Bio-Process Applications
|
|
|
DKK-TOA WBM-165H (2-wire)
|
|
Conductivity Transmitter with HART Interface WBM-165H (2-wire)
HART communication protocol interface with a 2-wire, 24 VDC circuit
Aluminum diecast enclosure, digital display and a wide range of other useful features
One-touch auto calibration
Self-diagnostic function
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm
|
Transmitter for Industrial Conductivity Analyzer
|
|
|
DKK-TOA WBM-160 (4-wire)
|
|
Industrial Conductivity Transmitter WBM-160 (4-wire)
Multi-function conductivity analyzer for field installation in a compact aluminum diecast enclosure
Wide application range from ultrapure water to wastewater
2-point contact signal, 2-channel output including temperature (RS-232 optional)
Power supply: AC90 - 264V, 50/60Hz
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm |
Transmitter for Industrial Conductivity Analyzer
|
|
|
DKK-TOA WDM-135A (2-wire) / WDM-136A (4-wire)
|
|
Industrial Conductivity Transmitter WDM-135A (2-wire) / WDM-136A (4-wire)
Easy-to-use conductivity analyzer for field installation in a compact and rigid aluminum enclosure
Wide application range from ultra-pure water to wastewater
Alterable output range
Meas. range
Minimum: 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm |
Transmitter for Industrial Conductivity Analyzer
|
|
|
DKK-TOA WBM-121A / AK Cell
|
|
Sanitary Type Conductivity Analyzer/Detector WBM-121A / AK Cell
Compact DIN 96 size
Designed for sanitary conductivity analyzer for the food industry
Applied in foodstuff plants and installed in pipes and tanks. Best suited for CIP (stationary cleaning) management, debubbling agent control and liquid level management
Meas. range
0 - 300/3000 μS/cm (at 25 degrees C) 0 - 20/200 mS/cm (at 25 degrees C)
|
Panel Type Conductivity Analyzer
|
|
|
DKK-TOA WBM-210A
|
|
Compact DIN 96 size
Conductivity meter with built-in microcomputer for various applications such as ultra-pure water production, boiler plants, foodstuff plants, etc.
Two detectors connectable
RS-232 equipped as standard specification
Output: 2-channel, insulated, 4 - 20mA
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm
|
Panel Type Conductivity Analyzer
|
|
|
DKK-TOA WBM-100
|
|
Compact DIN 96 size
Temperature compensation computed by a microcomputer
Cell constant value adjustable depends on customers' need
Water temperature displayable
Power supply: AC90 - 264V, 50/60Hz
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm
|
Panel Type Conductivity Analyzer
|
|
|
DKK-TOA AA-1(for Standard) / AA-2 (for Ultrapure Water)
|
|
Single-function (no indication) conductivity analyzer for field installation
Easy installation for the one-unit amplifier and detector
Output: 4 - 20mADC
Power supply: 100VAC
Meas. range
AA-1: 0 - 2 μS/cm to 0 - 10000 μS/cm AA-2: 0 - 0.2/0.5/1.0 μS/cm
|
Conductivity Detectors with Amplifier
|
|
|
DKK-TOA AR4/AR5 Series
|
|
Compact 2-electrode type (titanium) detector designed for ultrapure water
Pipeline insertion type, leadless type
Two types of cell constants available: 0.01, 0.1 cm-1
Meas. range
0 - 20/200 MΩ·cm 0 - 0.2/2 μS/cm
|
Industrial Conductivity Detector
|
|
|
DKK-TOA A5/A6 Series
|
|
Hermetically sealed 2-electrode type detector featured with excellent heat-proofing and pressure tightness
Pipeline-insertion/immersion/flow-through/throw-in/leadless, etc. type available
Four types of cell constants available: 0.01, 0.1, 1.0, 10 cm-1
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm
|
Industrial Conductivity Detector
|
|
|
DKK-TOA AQM-210A
|
|
Panel Type Resistivity Analyzer AQM-210A
Compact DIN 96 size
Best suited for water quality control in ultra-pure water production lines
Two detectors connectable
RS-232 equipped as standard specification
Output: 2-channel, insulated, 4 - 20mA
Meas. range
0.00 - 20.00 MΩ・cm
|
Panel Type Resistivity Analyzer for Ultra-Pure Water
|
|
|
DKK-TOA AQM-100A
|
|
Resistivity Analyzer for Ultra-Pure Water AQM-100A
Compact DIN 96 size
Best suited for water quality control in ultra-pure water production lines
Two detectors connectable
Meas. range
0.00 - 20.00 MΩ・cm
|
Panel Type Resistivity Analyzer for Ultra-Pure Water
|
|
|
DKK-TOA MBM-162 (4-wire)
|
|
Electromagnetic Concentration Transmitter MBM-162 (4-wire)
Electromagnetic concentration analyzer for field installation in a compact aluminum diecast enclosure
Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%) data automatically
2-point contact signal, 2-channel output including temperature (RS-232 optional)
Examples of measurement ranges
NaCl: 0~10% HCl: 30~40% H2SO4: 93~99.5% NaOH: 0~15%
|
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA MBM-160(4-wire)
|
|
Electromagnetic Conductivity Transmitter MBM-160(4-wire)
Electromagnetic conductivity analyzer for field installation in a compact aluminum diecast enclosure
Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali)
2-point contact signal, 2-channel output including temperature (RS-232 optional)
Power source: 90 - 264VAC, 50/60Hz
Meas. range
Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm |
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA MDM-137A (2-wire)
|
|
Electromagnetic Concentration Transmitter MDM-137A (2-wire)
Electromagnetic concentration analyzer for field installation in a compact and rigid aluminum enclosure
Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%)data automatically
Assignable measurement range
Examples of measurement ranges
NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15%
|
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA MDM-135A (2-wire)
|
|
Electromagnetic Conductivity Transmitter MDM-135A (2-wire)
Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum enclosure
Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali)
Alterable output range
Meas. range
Minimum : 0 - 2 mS/cm Maximum : 0 - 2000 mS/cm
|
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA MBM-102A
|
|
Panel Type Electromagnetic Concentration Analyzer MBM-102A
Compact DIN 96 size
Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%) data automatically
Assignable measurement range
2-point contact signal, 4 - 20mA output (RS-232 optional)
Examples of measurement ranges
NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15% |
Panel Type Electromagnetic Conductivity/Concentration Analyzer
|
|
|
DKK-TOA MBM-100A
|
|
Panel Type Electromagnetic Conductivity Analyzer MBM-100A
Compact DIN 96 size
Accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali)
2-point contact signal, 4 - 20mA output (RS-232 optional)
Meas. range
Minimum : 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm
|
Panel Type Electromagnetic Conductivity/Concentration Analyzer
|
|