Thanks to the new instrument functions, the Testo flue gas analyzers of the new testo 330-LL series now offer you even more professional and reliable support. These are the main features: • High-resolution colour display for the graphic representation of your measurement data • Extended measurement menus – such as gas pipe testing – for a comprehensive analysis of your heating system • Logger function for easy long-term recording of the measurement curve

• Graphic processing of measurement data
• Instrument diagnosis function uses easy „traffic light’’ presentation to enable comprehensive instrument diagnosis
• Pressure measurement up to 300 mbar
• User-defined fuels
• TÜV-tested according to 1. BImSchV / EN 50379 Part 2 for O2, °C, hPa and CO with H2-compensation
• Powerful memory management: 500,000 readings
• IrDa/ Bluetooth interface for data transfer to Pocket-PC / laptop / printer
• USB interface for data readout to a PC software
• ZIV (Central Guild Association) driver for all standard industry software packages
 
  Measuring range Accuracy ±1 Digit Resolution Adjustment
time t90

Temperature

-40 to +1200 °C ± 0.5 °C (0.0 to +100.0 °C)
±0.5% of reading (remaining measuring range)
0,1 °C (-40 to +999,9 °C) 1 °C (remaining meas. range)  

Draught measurement

-9.99 to +40 hPa ±0.02 hPa o. ±5% of. m.v. (-0.50 to +0.60 hPa)
± 0.03 hPa (+0,61 to +500 hPa)
±1.5% of reading (+3.01 to +40.00 hPa)
(the greater value applies)
0.01 hPa  

Pressure measurement

0 to 300 hPa ±0.5 hPa (0,0 - 50.0 hPa)
±1% of reading (50.1 to 100.0 hPa)
±1.5% of m.v. (remaining meas. range)
0.1 hPa  

O2measurement

0 to 21 vol. % ±0.2 Vol.% 0.1 vol. % < 20 sec

CCO measurement (without H2 compensation)

0 to 4000 ppm ±20 ppm (0 - 400 ppm)
±5% of reading (401 to 2000 ppm)
±10% of reading (2001 to 4000 ppm)
1 ppm < 60 sec

CO measurement
(H 2-compensated)

0 to 8000 ppm Display range 8000 to 30,000 ppm (automatic dilution) ±10 ppm or ±10% of m.v. (0 to 200 ppm)
±20 ppm or ±5% of m.v. (201 to 2000 ppm)
±10% of reading (2001 to 8000 ppm)
1 ppm < 60 sec

Only testo 330-2 LL CO measurement (H2compensated) solid fuel measurement

0 to 30,000 ppm ±100 ppm (0 to 1000 ppm)
±10% of reading (1001 to 30,000 ppm)
1 ppm  

Efficiency testing (Eta)

  0 to 120% 0.1 %  

Exhaust gas loss

  0 to 99.9% 0.1 %  

CO 2 -determination
digital calculation from O2

Display area 0 to CO 2 max ±0.2 Vol.% 0.1 vol.% < 40 sec

Option CO low measurement

0 to 500 ppm ±5 ppm (0 - 100 ppm)
±5% of reading (101 to 2000 ppm)
±10% of reading (2001 to 3000 ppm)
0.1 ppm < 30 sec

Option NO measurement

0 to 3000 ppm ±5 ppm (0 - 100 ppm)
±5% of reading (101 to 2000 ppm)
±10% of reading (2001 to 3000 ppm)
1 ppm < 30 sec

Ambient CO measurement
(with CO probe)

0 to 500 ppm ±5 ppm (0 to 100 ppm)
±5% of m.v. (>100 ppm)
1 ppm approx. 35 sec

Gas leak measurement for combustible gases (with gas leak detector probe)

Display area 0 to 10,000 ppm
CH 4 / C 3 H 8
Signal
Optical display (LED)
Audible alarm via buzzer
  < 2 sec

Ambient CO2measurement (with ambient CO 2 probe)

0 to 1 vol. % 0 to 10,000 ppm ±(50 ppm ±2% of reading) (0 to 5000 ppm)   approx. 35 sec

NOlow

0 to 300 ppm ±2 ppm (0 - 39,9 ppm)
±5% of reading (40 to 300 ppm)
0.1 ppm < 30 sec

General technical data

Storage temp.

-20 to +50 °C

Oper. temp.

-5 to +45 °C

Power supply

Rech. batt. block 3.7 V / 2,6 Ah Mains unit 6 V / 1.2 A

Memory

500,000 readings

Display

Colour graphic display with 240 x 320 Pixel

Weight

600 g (excluding battery)

Dimensions

270 x 90 x 65 mm

Warranty

Instrument/probe/gas sensors (O2, CO) 48 months
NO-, COlowsensor 24 months
Thermocouple and rech. battery 12 months
 
 
 
testo 310

testo 320

testo 330 LL

Measurement parameters

O2

0 to 21 % 0 to 21 % 0 to 21 %

CO

0 to 4000 ppm 0 to 4000 ppm 0 to 4000 ppm

Option: CO H2 compensated

false 0 to 8000 ppm 0 to 8000 ppm

COlow

false 0 to 500 ppm 0 to 500 ppm

NO

false false 0 to 3000 ppm

NOlow

false false 0 to 300 ppm

Differential pressure

0 to 40 hPa 0 to 300 hPa 0 to 300 hPa

Temperature

0 to 400 °C -40 to +1200 °C -40 to +1200 °C

Additional applications

Flow, system, static and jet pressure

true true true

Gas leak probe

false true true

Probe for ambient
CO measurement

false true true

Solid fuel measurement

false false true

Tightness test
on gas pipes

false false true

Instrument technology

Display

2-line segment Colour display Colour display

Communication

IR IRDA / USB / BT IRDA / USB / BT

Printer integration

true true true

Sensor diagnosis

false true true

Connection to PC or laptop

false true true

Sensor exchange by user

false true true

Measurement report memory

false 500 500.000

Warranty

2 years 2 years 4 years
 