WM-01/02 Power Analyzer Datalogger
|
|
4 LCD Displays with W, PF, V, A
Easy Plug-in and Test
RS-232 Computer Interface
|
Power Analyzer
|
|
|
TES-92 ElectroSmog Meter
|
|
50 MHz to 3.5 GHz frequency range.
For isotropic measurements of electromagnetic fields.
Non-directional (isotropic ) measurement with three-channel measurement probe.
High dynamic range due to three-channel digital results processing.
Configurable alarm threshold and memory function.
Easy to use
High frequency (RF) electromagnetic wave field strength measurement.
Mobil phone base station antenna radiation power density measurement.
Wireless communication applications (CW , TDMA ,... |
EMF Tester
|
|
|
TES-6830+6801 Power and Harmonics Analyzer (100A) TES-6830+6802 Power and Harmonics Analyzer (1000A) TES-6830+3007 Power and Harmonics Analyzer ( 3000A)
|
|
Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS Value (V 123 and L 123 )
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA, KVAR)
Power Factor (PF), Phase Angle (Φ)
Energy (WH, KWH, KVARH, PFH)
Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
Display of 35 Parameters in One Screen(3P4W)
Programmable CT (1 to 600) and PT (1 to 3000) Ratios
Display of Overlapped Voltage and Current Waveform
2.4M... |
3 Phase Power Analyzer
|
|
|
TES-593 ElectroSmog Meter
|
|
Frequency range 10MHz to 8.0GHz
3 axis isotropic measurements of EMF
Non-directional (isotropic) measurement with three-channel measurement probe
High dynamic range
Configurable alarm threshold and memory function
Easy & safety to use
High frequency (RF) electromagnetic wave field strength measurement
Mobile phone base station antenna radiation power density measurement
Wireless communication applications (CW, TDMA, GSM, DECT)
RF power measurement for... |
EMF Tester
|
|
|
TES-52 Sound Level Meter
|
|
0.1dB Resolution
Range from 30 to 130dB
A&C frequency weighting
Fast/Slow Dynamic characteristic
Maximum with Elapsed time
Manual data memory and read
5Selectable Ranges
Bargraph Indication
Logging Function (99 Sets)
|
Sound Level Meter
|
|
|
TES-46 CAT-5 Lan Cable Tester
|
|
Tests : UTP. FTP. Coax cables, two, three, or four wire pairs in twisted pair cables and test all category UTP cables and hardware.
Verify end-to-end connectivity per EIA/TIA 568 wiring standard.
Detects wiring problems : Opens, Shorts, miswires (Crossed, Reversed, Split pair).
Locates wiring/connection errors (distance to the open or shout)
Measures cable length
Easy to use only : One button to select the test and two lines characters LCD display.
Low battery, Auto power off, long... |
Lan Cable Tester
|
|
|
TES-45 CAT-5 Lan Cable Tester
|
|
Test a wide range of UTP cables such as 10Base T , 100Base Tx , 10Base 2 (Coax), 356A , TIA-568A , TIA-568B, etc.
Can tests for wiring faults such as open, short , reversed , crossed and split wires.
Can identify up to 4 different cables at one end by provided remote identifiers.
Double digital 14-segment LED and 4 pair LEDs clearly display the fault status.
Provided over voltage (max.56V) protection to prevent damage frommiss connecting to live circuit of networking.
Simple and... |
Lan Cable Tester
|
|
|
TES-3660 Autoranging Insulation Tester
|
|
Large LCD with analog bar graph and digital display.
250V, 500V, 1000V output voltage for insulation M Ω testing.
4000M Ω insulation testing with automatically switch to voltage measurement.
Lo Ω function for testing connections.
Autodischarge of capacitive voltage charges.
Last reading HOLD display.
AC/DC voltage measurement up to 1000V.
Manual data memory and read function (9 sets).
Meets EN61557 and IEC1010-1, CAT III 1000V.
Size : 235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)
|
Insulation Tester
|
|
|
TES-3600 3P4W POWER ANALYZER
|
|
10 Display Easy - to - View LCD Screen.
Connectors for 4 Current Sensing Clamps.
1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
True RMS Sensing.
Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement.
Phase sequency indicator function.
Backlight display function.
Manual Data Memory and Read (99 sets).
Data Logging (504KB Memory, 20,000 sets)
Programmable Trigger - Points and Start / Stop Time.
RS-232 Optical Interface with three phase voltage / current... |
3 Phase Power Analyzer
|
|
|
TES-33 Battery Capacity Tester (USB)
|
|
Test Condition Without Shutting Down Battery.
Simultaneously Measure Battery Resistance, Voltage, Current, Temperature.
Auto-hold and Auto-data storage.
Comparator Function.
Rates Conditions as Pass, Warning, or Fail.
Memory and Read Function
Compact and Lightweight.
USB PC Interface
Storage Battery Systems Battery Capacity Testers, Check battery condition in seconds, with the battery in service!
|
Battery Impedance Tester
|
|
|
TES-32 Battery Capacity Tester (RS-232)
|
|
Test Condition Without Shutting Down Battery.
Simultaneously Measure Battery Resistance, Voltage.
Comparator Function.
Rates Conditions as Pass, Warning, or Fail.
Memory and Read Function
Compact and Lightweight.
RS232 PC Interface
|
Battery Impedance Tester
|
|
|
TES-3096 DC/AC KW CLAMP METER
|
|
Compact Size
Trms KW measurement
AC/DC Current Measurement (AC 600A/DC 600A)
600V AC & 600V DC, Ohm/Continuity Beeper
600 V AC & 600 V DC. Ohm/Continuity Beeper
One Touch DCA Zero
|
Power Clamp Meter
|
|
|
TES-3092 DC/AC CLAMP METER
|
|
3-1/2 Digital LCD, 2000 count.
Pocket size.
MAX hold / Data hold function.
One touch DCA zero.
|
DC/AC Current Clamp Meter
|
|
|
TES-3091R DC/AC CLAMP METER
|
|
3-1/2 Digital LCD, 2000 count.
Pocket size.
MAX hold / Data hold function.
|
DC/AC Current Clamp Meter
|
|
|
TES-3082 True RMS Clamp Meter
|
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE2
Auto-Ranging Frequency measurements
Auto ZERO mode
Data Hold mode
PEAK Hold mode
True RMS Reading
|
DC/AC Current Clamp Meter
|
|
|
TES-3079K Power Clamp Meter
|
|
HVAC Application:
Check current draw in motors and compressors.
Use MAX/MIN/Recording in the temperature mode to assess efficiency.
Test run/start capacitors.
Confirm low voltage control signals.
Measure flame safeguard device current draw.
Confirm power sources.
Analyze temperature and voltage or current data with the aid of the time stamp.
Insulation test up to 100M Ω.
Electrical Application:
Check for energized circuits and balance loads.
1 Φ /3 Φ (3P3W/3P4W)Power... |
Power Clamp Meter
|
|
|
TES-3074 AC 1000A Clamp Meter
|
|
Capacitance Measurement (400μF).
MAX / MIN / Data Hold.
Phase Rotation Indicator.
Pos Peak Hold & Neg Peak Hold.
1000A AC & 600V AC.
|
DC/AC Current Clamp Meter
|
|
|
TES-3063/3064 Power AC/DC Clamp Meter
|
|
1 Φ 2W, 1 Φ 3W,3 Φ 3W,3 Φ 4W
RS-232 interface to talk with PC
4 digits with dual display LCD
Amp / Voltage f requency measurement
Dual display KW+PF , KVA+PF , V+A
4000 continuity point data logger , 25 point manual data logger
True power / apparent power / power factor measurement
True RMS. V , A , W , cap , lnd , phase indicator
MIN / MAX measurement
Peak hold detector
Dual display A+Hz , V+Hz
EN61010-1 600V Installation CAT III Pollution Degree 2 |
Power Clamp Meter
|
|
|
TES-3050 TRMS AC/DC Clamp Meter
|
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE 2
3-3/4 Digital LCD with bar-graph
Auto-ranging off / Data Hold / Peak Hold / MAX/MIN mode
Zero Adjustment/Relative Reading
|
DC/AC Current Clamp Meter
|
|
|
TES-3040 AC Clamp Meter
|
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE 2
3-3/4 Digital LCD with bar-graph
Auto-power off with Data Hold and MAX/MIN mode
Zero Adjustment/Relative Reading
|
DC/AC Current Clamp Meter
|
|