DKK-TOA

  • Filter
  Name SKU Description Category
DKK-TOA HM-30R Large color graphic LCD display 0.01/0.001 pH display switchable High-performance with the Strong&Float (internal solution concentration checker) pH electrode USB (Host) and LAN equipped Multiple sample measuring capability (turntable connection) Meas. range pH 0.000 - 14.000 0.0 - ±2000.0mV (ORP electrodes sold separately) 0 - 100.0℃ pH meters
DKK-TOA HDM-135A(2-wire)/HDM-136A(4-wire) Industrial pH Transmitter HDM-135A(2-wire)/HDM-136A(4-wire) Easy-to-use pH analyzer for field installation in a compact and rigid aluminum enclosure Easier calibration done with standard solution Auto determination of electrode deterioration Alterable output range Automated self-diagnosis of fault (burn-out output) Meas. range -1 - 14 Transmitter for Industrial pH/ORP Analyzer
DKK-TOA HM-30P / 31P Standard model for pH measurement (HM-30P) Sophisticated type, capable of pH and ORP measurements (HM-31P) Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins) Data storage up to 1000 points  Meas. range pH 0 - 14 (HM-30P/31P) 0 - 100.0 degrees C (HM-30P/31P) 0 - ±2000 mV (HM-31P) (ORP electrodes sold separately) Handheld pH/ORP Meter
DKK-TOA WDM-135A (2-wire) / WDM-136A (4-wire) Industrial Conductivity Transmitter WDM-135A (2-wire) / WDM-136A (4-wire) Easy-to-use conductivity analyzer for field installation in a compact and rigid aluminum enclosure Wide application range from ultra-pure water to wastewater  Alterable output range Meas. range Minimum: 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm Transmitter for Industrial Conductivity Analyzer
DKK-TOA AQM-100A Resistivity Analyzer for Ultra-Pure Water AQM-100A Compact DIN 96 size Best suited for water quality control in ultra-pure water production lines  Two detectors connectable Meas. range 0.00 - 20.00 MΩ・cm Panel Type Resistivity Analyzer for Ultra-Pure Water
DKK-TOA MDM-135A (2-wire) Electromagnetic Conductivity Transmitter MDM-135A (2-wire) Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum enclosure  Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) Alterable output range Meas. range Minimum : 0 - 2 mS/cm Maximum : 0 - 2000 mS/cm Transmitter for Electromagnetic Conductivity Analyzer
DKK-TOA OBM-102A Panel type DO analyzer in a compact DIN 96 size One-touch calibration and various self-diagnostic functions 2-point contacts signal, 4 - 20mA output (RS-232 optional)  Power supply: 90 - 264VAC, 50/60Hz Meas. range Minimum : 0 - 1 mg/L Maximum: 0 - 50 mg/L Panel Type DO Analyzer
DKK-TOA XAT-200 series Process analyzer for automating analytical techniques such as atomic absorption and etc. Suitable for automating chemical analysis processes such as distillation, heat treatment, etc. Example applications:  *Total chromium  *Total cyanide by atomic absorption/distillation  *Phenols by atomic absorption/distillation  *Total mercury by oxidation-reduction atomic absorption Automatic Process Analyzer
DKK-TOA MWB4-70 B4 size compact analyzer excellent in reliability, durability and maintainability Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents Equipped with interactive easy-to-use color touch panel Automatic Water Quality Analyzer for City Water
DKK-TOA BSC A complete sampling system composed with cooler, pressure reducer, valves, flowmeter and thermostat chambers Enables sampling for analysis from the boiler Consistent manufacturing from analyzer to sampler Sample condition Maximum temperature: 600 degrees C Maximum pressure: 30 MPa Maximum flow rate: 3 L/min Boiler Sampling System
DKK-TOA BPM-2000 Designed for oil refinery  Automatic fractional distillate analyzer of batch distillation type enables distillation test of petroleum products such as kerosene, diesel oil, gasoline and etc. Adopts high resolution liquid level detecting sensor Newly-developed FA computer embedded with large-sized, color touch panel Explosion-proof TIIS fd2G4 certified Meas. range Standard:Light gas oil (0 - 400 degrees C), Kerosene (0 - 300 degrees C), Gasoline (0 - 200degrees C) Boiling Point Analyzer
DKK-TOA NPW-160 Automated Total Nitrogen/Phosphorus/COD Analyzer NPW-160 Measuring based on official measuring method Multiple-wavelength detector enables measurement of total nitrogen, total phosphorus and COD simultaneously Space-saving design attained by eliminating back piping Drip-proof construction Meas. range Total nitrogen: 0 - 2 mg/L to 50 mg/L Total phosphorus: 0 - 0.5mg/L to 20 mg/L COD (UV method): 0 - 2 Abs Automatic Total Nitrogen/Phosphorus/COD Analyzer
DKK-TOA FPM-377 PM2.5 Monitor FPM-377 Environment Ministry (JAPAN) Approval Beta ray attenuation method (mass concentration) Heater type dehumidifier VSC cyclone (USEPA approval) Outdoor type and indoor type available  Meas. range 0 - 500, 0 - 1000, 0 - 5000 μg/m3 Particulate Monitor
DKK-TOA CM-30R JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement  Built-in pure water temperature compensation  USB (Host) and LAN equipped as standard specification  Compliant with USP<645> requirements Meas. range 0 - 200.0 S/m 0 - 20.00 MΩ・m Chloride 0 - 4.00% Concentration 0 - 200% 0 - 100.0 degrees C Conductivity Meter
DKK-TOA WM-32EP 2-channel type, simultaneous measurement and display of pH/conductivity Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins) Data storage up to 1000 points PC and external printer connectable  Measurement items pH, ORP, conductivity, resistivity, salinity, temperature (ORP electrodes sold separately) Handheld Electrical Conductivity/pH Meter
DKK-TOA HBM-100A / HBM-102A Compact DIN 96 size design Auto-detection of electrode deterioration Automated self-diagnosis of fault (burn-out output) Alterable alarm contact signal (4-point) 2-channel output (RS-232 optional) Meas. range: HBM-100A: pH; -1 - 15 HBM-102A: ORP; -2000 - +2000 mV Panel Mount pH/ORP Analyaer
DKK-TOA WBM-100 Compact DIN 96 size Temperature compensation computed by a microcomputer  Cell constant value adjustable depends on customers' need Water temperature displayable Power supply: AC90 - 264V, 50/60Hz Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm Panel Type Conductivity Analyzer
DKK-TOA MBM-100A Panel Type Electromagnetic Conductivity Analyzer MBM-100A Compact DIN 96 size Accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) 2-point contact signal, 4 - 20mA output (RS-232 optional)    Meas. range Minimum : 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm Panel Type Electromagnetic Conductivity/Concentration Analyzer
DKK-TOA OC-711 / OC-950 Immersion/Drop-In Type DO Holder OC-711 / OC-950 Lightweight PVC holder; length of immersion type holder: 0.3 - 3.5 m, length of stainless steel protection pipe for drop-in type holder: 2 - 6 m Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste) Immersion/Drop-in Type DO Holder/Detector with Water Jet Cleaner
DKK-TOA BMR-24 Compact and lightweight model in accordance with DIN standard DC 24V power supply designed for 4-point alarm and 2-wire transmitters Often used as a receiver of 2-wire or 4-wire transmitter (such as pH/ORP meters, conductivity analyzers and DO meters)  Meas. range pH meter: pH; 0 - 14 70divisions (to be specified otherwise) Bar Graph Meter Relay