DKK-TOA MDM-135A (2-wire)
|
|
Electromagnetic Conductivity Transmitter MDM-135A (2-wire)
Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum enclosure
Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali)
Alterable output range
Meas. range
Minimum : 0 - 2 mS/cm Maximum : 0 - 2000 mS/cm
|
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA OBM-102A
|
|
Panel type DO analyzer in a compact DIN 96 size
One-touch calibration and various self-diagnostic functions
2-point contacts signal, 4 - 20mA output (RS-232 optional)
Power supply: 90 - 264VAC, 50/60Hz
Meas. range
Minimum : 0 - 1 mg/L Maximum: 0 - 50 mg/L
|
Panel Type DO Analyzer
|
|
|
DKK-TOA XAT-200 series
|
|
Process analyzer for automating analytical techniques such as atomic absorption and etc.
Suitable for automating chemical analysis processes such as distillation, heat treatment, etc.
Example applications:
*Total chromium *Total cyanide by atomic absorption/distillation *Phenols by atomic absorption/distillation *Total mercury by oxidation-reduction atomic absorption |
Automatic Process Analyzer
|
|
|
DKK-TOA MWB4-70
|
|
B4 size compact analyzer excellent in reliability, durability and maintainability
Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents
Equipped with interactive easy-to-use color touch panel
|
Automatic Water Quality Analyzer for City Water
|
|
|
DKK-TOA BSC
|
|
A complete sampling system composed with cooler, pressure reducer, valves, flowmeter and thermostat chambers
Enables sampling for analysis from the boiler
Consistent manufacturing from analyzer to sampler
Sample condition
Maximum temperature: 600 degrees C Maximum pressure: 30 MPa Maximum flow rate: 3 L/min
|
Boiler Sampling System
|
|
|
DKK-TOA BPM-2000
|
|
Designed for oil refinery
Automatic fractional distillate analyzer of batch distillation type enables distillation test of petroleum products such as kerosene, diesel oil, gasoline and etc.
Adopts high resolution liquid level detecting sensor
Newly-developed FA computer embedded with large-sized, color touch panel
Explosion-proof TIIS fd2G4 certified
Meas. range
Standard:Light gas oil (0 - 400 degrees C), Kerosene (0 - 300 degrees C), Gasoline (0 - 200degrees C)
|
Boiling Point Analyzer
|
|
|
DKK-TOA NPW-160
|
|
Automated Total Nitrogen/Phosphorus/COD Analyzer NPW-160
Measuring based on official measuring method
Multiple-wavelength detector enables measurement of total nitrogen, total phosphorus and COD simultaneously
Space-saving design attained by eliminating back piping
Drip-proof construction
Meas. range
Total nitrogen: 0 - 2 mg/L to 50 mg/L Total phosphorus: 0 - 0.5mg/L to 20 mg/L COD (UV method): 0 - 2 Abs
|
Automatic Total Nitrogen/Phosphorus/COD Analyzer
|
|
|
DKK-TOA FPM-377
|
|
PM2.5 Monitor FPM-377
Environment Ministry (JAPAN) Approval
Beta ray attenuation method (mass concentration)
Heater type dehumidifier
VSC cyclone (USEPA approval)
Outdoor type and indoor type available
Meas. range
0 - 500, 0 - 1000, 0 - 5000 μg/m3
|
Particulate Monitor
|
|
|
Lutron 50A/50mV SHUNT - ST-50
|
|
|
Adapter Series
|
|
|
Vaccine Temperature Monitoring System (VTMS) Data Logger
|
|
MadgeTechs Vaccine Temperature Monitoring System (VTMS) is ideal for the continuous measurement and data logging of temperature sensitive vaccines or pharmaceuticals in refrigerators, freezers, and coolers. The system includes a NIST traceable RFTCTemp2000A data logger with thermocouple, Glycol bottle and a power supply. Additionally, the RFTCTemp2000A data logger in the VTMS system has a convenient LCD to ensure temperature parameters are met, in real time. The current reading, minimum,... |
Wireless Data Loggers
|
|
|
3B5700
|
|
150°C ½ AA High Temperature Battery |
Data Logger Batteries
|
|
|
Fluke 90i-610s 1A to 600A AC/DC Current Probe
|
|
Current Range: 1 to 600 A DC or AC Peak
Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A)
Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A
Frequency Range: 40 Hz to 400 Hz
Working Voltage: 600 V AC rms
Maximum Conductor Diameter: 34 mm (1.34 inch)
Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V
|
Automotive Accessories
|
|
|
Fluke CIQ-100 CableIQ Qualification Tester
|
|
Qualifies - Sees if your existing cabling has the bandwidth to support voice, 10/100, VoIP or Gigabit Ethernet
Troubleshoots - shows why existing cabling cannot support the network's bandwidth requirement (e.g. crosstalk at 11 meters)
Discovers - detects what's at the end of any cable and displays device configuration (speed/duplex/pairing)
Identifies unused switch ports that can be reallocated
Graphically maps wiring configuration and shows distance to faults with Intelligent Wiremap... |
Copper Cable Test Solutions
|
|
|
Fluke Networks NetTool Series II Inline Network Tester
|
|
NetProve diagnostics – isolate device and application connectivity issues in seconds
Inline Gigabit vision - quickly troubleshoot network problems with powerful inline vision into 10/100/Gig traffic between switches, PCs, IP phones and other devices
NetSecure monitoring and authentication - identify spyware, malware, and viruses with port monitoring; troubleshoot authentication issues with 802.1x log
VoIP troubleshooting - connect inline for visibility into VoIP calls to quickly diagnose... |
Network Analyzers and Testers
|
|
|
Fluke Networks TS42DLX and TS44Pro Telephone Test Sets
|
|
Superior high-impedance monitoring
Data indication/warning
Low & high voltage indication/warning
Low current (mA) indication/warning Passive monitor
2-Way hands-free speakerphone
Low battery warning
Mute indication
Polarity indication
Tone & pulse dialing
(Optional) 1-Way amplified speakerphone mode
Amplified speaker
Last number redial
Over voltage protection
Over current protection
Mute
PBX pause button
Audible ringer
Speed dialing
Volume control... |
Telephone Test Sets / Butt Sets
|
|
|
Sew PC7k, PC11k, PC22k, PC33k, PC44k
|
|
● No user’s assembled parts.● Dual color-coded scale (%, Vac).● Neon indicator when >1200Vac.● Lightweight, robust & compact.● Carry case included.● Compare between phases.● Measure and test phase to earth.● High quality fiberglass wound rod.● Self powered operation. No battery required.● DC version available.● Measure phase to phase.● Hi immunity to interference fields.● Suitable for indoor and outdoor use.● Current is limited to ±1 milli-ampere.●... |
H.V. Multifuntion Phasing Sticks
|
|
|
Sew 2734 ER
|
|
● Microprocesser-controlled with advanced safety features.● 4-wire testing only.● Automatic C spike check.● Auto power-off.● Auto data hold.● Large LCD (2000 counts).● Protective terminal cover.
SPECIFICATIONS
Measuring ranges
Earth Resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth Voltage 0-200V AC
Accuracy
Earth Resistance ±2%rdg±3dgt Earth... |
4 Wire Earth Resistance Testers
|
|
|
Sew 6200 IN (Ranges: 2.5kV, 5kV)
|
|
FEATURES
● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.
SPECIFICATIONS
Test voltage (DC V)
2500V
5000V
Measuring ranges
0-100GΩ
0-200GΩ
... |
Analogue (1kV up) H.V. Insulation Testers
|
|
|
Sew 1151 IN
|
|
FEATURES
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at Switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal... |
Insulation & Multifunction Testers (LCD Display)
|
|
|
Sew TEL-1-1 110V
|
|
FEATURES
● The TEL1 is the Basic Test Equipment an Electrician cannot do without. TEL1 is a Dual Function Test Instrument utilized to Verify Electrical Wiring Connections and the Functioning of Earth Leakage / Residual Current Detectors devices by forcing the ELCB/RCD to trip.
SPECIFICATIONS
Nominal Voltage System
110V-220V-230V-240Vac... |
General ELCB Testers
|
|