PROVA-100 4-20mA LOOP CALIBRATOR
|
|
4-20mA, with 1 μ A resolution
Basic Accuracy 0.025% + 5 μ A
Auto-Ramp and Easy Step Functions
1-100% Input
0-20mA, 0-24mA Selectable
Easy Just-Type-in Number Operation
|
Calibrator
|
|
|
PROVA-5601/5637 Clamp-on Ground Resistance Tester
|
|
Non-Contact Ground Resistance Measurement
No Auxiliary Electrode Needed
Jaw Diameter Φ 23 mm (5601)
Jaw Diameter Φ 35 mm(5637)
0.025 – 1500 Ohm
0.2mA– 30A(5601)0.2mA– 35A(5637),True RMS
116 Sets of Memory(5601,5637)
Programmable Hi and Lo Alarm(5601,5637)
Programmable Data Logging (5601,5637)
Telecommunication
Cable TV system
Electrical Power Plant
Cellular Phone System
Factory and Facility
Gas Station Tank
|
Earth / Ground Tester
|
|
|
PR140 Data Logger
|
|
The PR140 is a pressure data logger designed for use in autoclave validation and mapping. This rugged data logger can withstand temperatures up to 140°C and is completely submersible (IP68). The PR140 is built with a precision stainless steel pressure gauge. The data logger has an accuracy of ±0.03 Bar (±0.435 PSI), which can be achieved over a wide temperature range, from 20°C to +140°C (68°F to 284°F). The PR140 can be programmed to take readings as often as once per second (1Hz), and... |
Pressure
|
|
|
Pulse101A Data Logger
|
|
The Pulse101A is one of MadgeTech’s best selling data loggers. It is part of an original series of low cost, state-of-the-art data logging devices. MadgeTech has taken the lead in offering the most advanced, low cost, battery powered data loggers in the world today.
The Pulse101A offers a 10 year battery life, 1 second reading rate, a multiple start/ stop function, ultra-high speed download capability, 500,000 reading storage capacity, optional memory wrap, battery life indicator, optional... |
Pulse/Event/State
|
|
|
Process101A Data Logger
|
|
The Process101A is one of MadgeTech’s newest data loggers. It is part of a new series of low cost, state-of-the-art data logging devices. MadgeTech has taken the lead in offering the most advanced, low cost, battery powered data loggers in the world today.
The Process101A is available in three ranges, 20mA, ±160mA and ±3A. All of the ranges offer a 10 year battery life, a 4Hz reading rate, a multiple start/stop function, ultra-high speed download capability, 1 million reading storage... |
Current/Voltage
|
|
|
pHTemp101 Data Logger
|
|
The pHTemp101 is a miniature, battery powered, stand alone pH and temperature data logger. The device measures full range from 0 to 14pH. The data logger directly connects to industry standard pH and ORP probes with female BNC connectors. Temperature compensation is provided through an external RTD temperature channel.
This is an all-in-one compact, portable, easy to use device that will measure and record data for up to 13,107 measurements per channel. It's small size and internal memory make... |
pH
|
|
|
PULS DIN-Rail Power Supplies for 1-phase Systems
|
|
AC 100-240V DC 110-150V |
PULS Power Supplies
|
|
|
PROVA-6600 3 Φ Power Clamp
|
|
3 f 4W, 3 f 3W, 3 f Balanced, 1 f 2W, and 1 f 3W Power Measurement.
AC+DC true power, and True RMS AC Voltage and Current
AC+DC 2000A, AC 600V, DC 800V
AC+DC 1200KW(1 f ), AC+DC 2000KW (3 f )
Dual Display V+Hz, A+Hz, W+PF, KVA+KVAR, V+A
Phase Angle Measurement
3 f RST(L1L2L3) Sequence Indication.
Memory of 4 records.
DCA/DCW Auto Zero when power clamp powering on.
AC/DC Auto Detection.
Auto range.
|
Power Clamp Meter
|
|
|
PROVA-8000 Programmable Power Supply
|
|
Over-Voltage , Over-Current Protection
Built-in Buzzer Alarm
Easy RECALL and STORE functions
Stby / Operate Button
English-like RS-232C commands
OCP With Programmable Timer
200 Sets of Memory
AUTO-STEP function with programmable interval
Bi-direction RS-232C interface
3.8 kg / 8.4 Lbs weight
|
Power Supply / Inverter
|
|
|
PROVA-300XP Portable Thermal Printer
|
|
Portable Field Printing for Certificate
Text and Graphics
Two Selectable Fonts (5*7 and 8*16)
Programmable text Header and Footer
Battery and AC Power Adaptor
RS-232C Interface (Optional RS-232C to USB Bridge)
Fixed Interval Continuous Printing(5, 30, 60, 300 seconds)
|
Printer
|
|
|
PROVA 700 Milli-Ohmmeter
|
|
Best resolution 1μΩ. Accuracy 0.05%
5A (120 mΩ) max. test current.
Manual or Auto Range. (There are 6 ranges of current measurement, and furthermore 3 ranges in each current range.)
Measurement of resistive and inductive materials (Two terminal measurement; Four terminal Kelvin measurement)
Programmable Hi-Lo alarm with memory of 20 data.
Auto-judgments of Hi (readings higher than Hi-Limit), Lo (readings lower than Lo-Limit) and Pass (readings between Hi-Lo Limits). Alarm (beeper) for... |
Milli-Ohmmeter
|
|
|
PROVA-125 Temperature Calibrator
|
|
Simple & Easy to key-in the exact temperature value you need
Dual LCD display to show the Reference Room Temperature at the same time
Accept 11 different type of Thermocouple (K, J, E, T, R, S, N, L, U, B, C)
Auto-Ramp & T function
|
Calibrator
|
|
|
PR2000 Data Logger
|
|
The PR2000 is a battery powered pressure data logger, with an LCD. It is perfect for applications requiring displayed pressure readings and a logger.
The 8-button keypad and large LCD provide convenient access to current data and data logger setup. Additionally, memory and battery levels, external power status, and sampling and recording status are shown on the LCD.
Available on-screen data includes: statistics (min, max, average); recording status (start, stop and recording rate); display... |
Pressure
|
|
|
pHTemp2000 Data Logger
|
|
The pHTemp2000 is a battery powered, stand alone pH and temperature data logger with an LCD. This all-in-one compact, portable, easy to use device will measure and record data up to 131,071 readings per channel. The pHTemp2000 will directly connect to many commonly used pH and ORP electrodes through a female BNC connector mounted on its side. Temperature is measured by directly connecting an RTD to the pHTemp2000. Temperature compensation is automatically done internally to the unit.
The... |
LCD Display
|
|
|
pHTemp2000 Data Logger
|
|
The pHTemp2000 is a battery powered, stand alone pH and temperature data logger with an LCD. This all-in-one compact, portable, easy to use device will measure and record data up to 131,071 readings per channel. The pHTemp2000 will directly connect to many commonly used pH and ORP electrodes through a female BNC connector mounted on its side. Temperature is measured by directly connecting an RTD to the pHTemp2000. Temperature compensation is automatically done internally to the unit.
The... |
pH
|
|
|
PULS DIN-Rail Power Supplies for 3-phase Systems
|
|
AC 380-480V |
PULS Power Supplies
|
|
|
PROVA-8500 Energy-Saving Tester
|
|
Standby power measurement ( 0 to 100W width 0.001W resolution)
Regular power(0~2000W)
100W AC power supply + AC power analyzer]
Programmable nominal output (85V to 250V , 45Hz to 65Hz)
power quality measurement (W , PF , V , A)
PC programmable through RS-232C interface( Optional RS-232C to USB bridge)
Programmable Over current protection (OCP)
Memory of 99 preset voltage and frequency
Standby and Operation Button
Back space for easy correction
Standby power measurement of note... |
Power Analyzer
|
|
|
PROVA-6601 3 Φ PF Power Clamp
|
|
PF( 3 Φ 3W , 3 Φ 4W 1Φ 2W )
AC+DC 2000A, 600V Power Factor
AC+DC 1200KW(1 Φ ) AC+DC 200KW(3Φ )
AC/DC Auto Detection
Dual Display V+Hz, A+V,KW+PF,KVA+KVAR
|
Power Clamp Meter
|
|
|
PROVA 200A/210 Solar Module Analyzer
|
|
60V, 6A (PROVA 200A) 60V, 12A (PROVA 210)
I-V Curve Test for Solar Cell
Max. Voltage (Vmaxp) and Max. Current (Imaxp) at Max. Power (Pmax)
I-V Curve with cursor
Calculation of Efficiency (%)
|
Solar Power Meter
|
|
|
PROVA-123 Process Calibrator
|
|
4-20mA, 0-20mA, 0-24mA with 1 m A resolution
0-100mV with 10 m V resolution
0-12V with 1mV resolution
Thermocouple K,J,E,T TYPE 1 o C 1 o F resolution
Frequency 2 - 50,000Hz
|
Calibrator
|
|