DKK-TOA WQC-22A
|
|
Easy measurement of 6 items (pH, temp., DO, conductivity, turbidity, salinity)
Ideal for applications such as rivers, lakes, dams, etc.
Easy maintenance with cartridge electrode
Measurements at depth of 30m is achievable with specific electrodes
AC/DC 2-way power supply
|
Water Quality Checker
|
|
|
DKK-TOA DVP-03
|
|
Designed for oil refinery
Measures vapor pressure of petroleum products like gasoline
Vapor pressure is measured by measuring static pressure of the sample that is jetting out from the nozzle at the constant temperature
Measurement result attained via Reid method for vapor pressure
Meas. range
0.01 - 1 MPa abs 0 - 0.15 MPa abs
|
Vapor Pressure Analyzer
|
|
|
DKK-TOA TUF-1600
|
|
Suitable for water purification process (including river water, etc.)
Surface scattering light method employed; 1 range/2 ranges/3 ranges available
Reduces flow volume of sample water to 1/2 of existing models
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 2 to 0 - 2000 (1 - 3 ranges) (mg/L, ppm, FTU, NTU)
|
Turbidity Analyzer
|
|
|
DKK-TOA TUH-1600
|
|
High Sensitivity Turbidity Analyzer TUH-1600
Highly-sensitive turbidity analyzer suitable for water purification process
Surface scattering light method employed; 1 range/2 ranges/3 ranges available
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 0.2 to 0 - 2.0 (1 - 3 ranges) (NTU)
|
Turbidity Analyzer
|
|
|
DKK-TOA TUI-100
|
|
Turbidity Meter with Integrating Sphere TUI-100
Integrating sphere system employed for lab turbidity measurements
Continuous measurement of turbidity in tap water, river water, industrial water, etc.
Accurate results for minimized influence of color
Meas. range
0 - 0.5/5 to 0 - 100/1000 Cell length: 50mm or 10mm (selectable) (mg/L, ppm, FTU, NTU)
|
Turbidity Analyzer
|
|
|
DKK-TOA COL-110
|
|
Colorimeter/Turbidity Meter COL-110
Color and turbidity can be measured simultaneously by dual wavelength with just one meter
Equipped with interactive easy-to-use colortouch panel
Meas. range
Color: 0 - 10/20/30 (degrees C, DEG) Turbidity: 0 - 2/4/5/10 (degrees C, mg/L, ppm)
|
Turbidity Analyzer
|
|
|
DKK-TOA HDM-135A(2-wire)/HDM-136A(4-wire)
|
|
Industrial pH Transmitter HDM-135A(2-wire)/HDM-136A(4-wire)
Easy-to-use pH analyzer for field installation in a compact and rigid aluminum enclosure
Easier calibration done with standard solution
Auto determination of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
-1 - 14
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HDM-137A(2-wire)/HDM-138A(4-wire)
|
|
Industrial ORP Transmitter HDM-137A(2-wire)/HDM-138A(4-wire)
Easy-to-use ORP analyzer for field installation in a compact and rigid aluminum enclosure
Automatic check done with standard solution
Auto-detection of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
-2000 - +2000mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HBM-165H(2-wire)
|
|
pH / ORP Transmitter with HART Interface HBM-165H(2-wire)
HART communication protocol interface with a 2-wire, 24 VDC circuit
Available for both pH and ORP measurements
Diecast aluminum enclosure, digital display and a wide range of other useful features
One-touch auto calibration
Self-diagnostic function
Meas. range
-1.00 - 15.00 ORP -2000 - 2000 mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HBM-160/HBM-162(4-wire)
|
|
Industrial pH/ORP Transmitter HBM-160/HBM-162(4-wire)
Multi-function pH/ORP analyzer for field installation in a compact aluminum diecast enclosure
One-touch calibration and various self-diagnostic functions
2-point contact signal and 2-channel output including temperature (RS-232 optional)
Power supply: AC90~264V, 50/60Hz
Meas. range
pH meter (HBM-160) : pH -1 - 15 ORP meter (HBM-162) : ORP -2000 - +2000mV
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
|
|
Immersion Type Holder for Replaceable Tip Electrode HC-G70 (KCl Replenish-Free/Refillable) / HC-G72 (KCl Refillable)
HC-G70: Transparent PVC holder (heat resistance: 60 degrees C) and semi-transparent PP holder (heat resistance: 80 degrees C) available
HC-G72: SUS316 holder (heat resistance: 80 degrees C)
Length: 0.5 - 3.0m
KCl refillable type stores KCl inside the holder
Mounting bracket/flange available
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G95 (KCl Replenish-Free)
|
|
Drop-In Type Detector for Replaceable Tip Electrode HC-G95 (KCl Replenish-Free)
Two selections: throw-in type for deep tanks or drop-in type with a protection pipe
Made from transparent PVC (heat resistance: 60 degrees C)
SUS protection pipe (maximum length: 5 m) and mounting bracket available
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HC-G80 (KCl Replenish-Free/Refillable) / HC-G82 (KCl Replenish-Free/Refillable)
|
|
Flow-Through Type Holder for Replaceable Tip Electrodes HC-G80 (KCl Replenish-Free/Refillable) / HC-G82 (KCl Replenish-Free/Refillable)
HC-G80: Transparent holders made of PVC (heat resistance: 60 degrees C) ; maximum pressure resistance: 0.15MPa
HC-G82: PP/SUS316 part (heat resistance: 80 degrees C) and PVDF/SUS316 part (heat resistance: 100 degrees C) ; maximum pressure resistance: 0.3 MPa
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA PHC-7D
|
|
Immersion Type Sensor with Pulse Air Jet Cleaner PHC-7D
Immersion type pH/ORP electrode holder combined with pulse air jet cleaner
Cleaning by high-speed water stream created by the rapid expansion of pulse-jetted compressed air in the sample water
High cleaning effect due to air bubbles present in the water stream randomly hitting the electrode
No consumables required, such as reagents, brushes
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA ODM-100A (2-wire) / ODM-110A (4-wire)
|
|
Industrial Low-Concentration DO Transmitter ODM-100A (2-wire) / ODM-110A (4-wire)
Easy-to-use low-concentration DO analyzer for field installation in a compact and rigid aluminum case
Simplified calibration procedure; auto detection of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
Minimum: 0 - 20 μg/L Maximum: 0 - 2000 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA OBM-300 (4-wire)
|
|
Low-Concentration DO Transmitter OBM-300 (4-wire)
Multi-functional low-concentration DO analyzer for field installation in a compact diecast aluminum case
3 ranges (automatically switched), 2-point regulated output
Alterable output range
One-touch calibration and various self-diagnostic functions
Meas. range
Minimum : 0 - 20 μg/L Maximum: 0 - 999.9 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA OBM-100H
|
|
Panel Type Low-Concentration DO Transmitter OBM-100H
Panel type low-concentration DO analyzer in a compact DIN 96 size
2-point regulated, 4 - 20mA, RS-232 output
One-touch calibration and various self-diagnostic functions
Power supply: 90~264VAC, 50/60Hz
Meas. range
Minimum : 0 - 20 μg/L Maximum: 0 - 1000 μg/L
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA OC-64
|
|
Low-Concentration DO Detector for Pure Water OC-64
Suitable for low-concentration DO measurement (pure water in semiconductor factories, boiler water in power plants)
Micro-flow (100mL/min) with special flow cell
Electrode: polarograph type 7561L (Ag electrode) or 7563L (Au electrode)
Lead wire: ELW-32
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
DKK-TOA WDM-135A (2-wire) / WDM-136A (4-wire)
|
|
Industrial Conductivity Transmitter WDM-135A (2-wire) / WDM-136A (4-wire)
Easy-to-use conductivity analyzer for field installation in a compact and rigid aluminum enclosure
Wide application range from ultra-pure water to wastewater
Alterable output range
Meas. range
Minimum: 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm |
Transmitter for Industrial Conductivity Analyzer
|
|
|
DKK-TOA WBM-160 (4-wire)
|
|
Industrial Conductivity Transmitter WBM-160 (4-wire)
Multi-function conductivity analyzer for field installation in a compact aluminum diecast enclosure
Wide application range from ultrapure water to wastewater
2-point contact signal, 2-channel output including temperature (RS-232 optional)
Power supply: AC90 - 264V, 50/60Hz
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm |
Transmitter for Industrial Conductivity Analyzer
|
|