By Brands

Brands

  • Filter
  Name SKU Description Category
DKK-TOA GSS‐304B(KCl Replenish-Free) / GSS‐314B(KCl Refillable) Easy-to-replace electrode tip and  reference electrode junction tip Alkali-resistant glass tips and hydrofluoric-acid-resistant glass tips available KCl non-refillable type for wastewater treatment; KCl refillable type for processes Selection of electrode holder: immersion type, drop-in type and flow-through type Meas. range pH: 0 - 14 Exchangeable Tip pH Electrode
DKK-TOA PSS/ASS‐304B(KCl replenish-free) / PSS/ASS‐314B(KCl refillable) Exchangeable Tip ORP Electrode PSS/ASS‐304B(KCl replenish-free) / PSS/ASS‐314B(KCl refillable) asy-to-replace electrode tip and  reference electrode junction tip Platinum electrodes (PSS) and gold electrodes (ASS) available KCl non-refillable type is ideal for wastewater treatment; KCl refillable type for processes Selection of electrode holder: immersion type, drop-in type and flow-through type Meas. range ORP: -2000 - +2000 mV Exchangeable Tip pH Electrode
DKK-TOA HC-7 Series Ideal for pH/ORP measurements in tanks and open water applications Assemble electrodes available: 5600 (KCl refillable type); 5910 (KCl  replenish-free type) Mounting flanges for tanks available (50A, 100A, 150A) Immersion Type pH/ORP Detector
DKK-TOA HC-8Series Designed for pH/ORP measurements in closed loop lines and environments where process pressure exists, such as pipes or sealed tanks and etc.  Assemble electrodes available: 5610(KCl refillable type); 5910(KCl replenish-free type) Flow-Through Type pH/ORP Detector
DKK-TOA HC-64 Ideal for pure water measurements like boiler water (low electric conductivity)   Low flow injection of sampling allows for accurate measurement Assemble electrodes available: MG-511-2F (glass electrode) 4164-2F (reference electrode) 6149-2F (temperature compensation electrode) pH Sensor for Pure Water Measurement
DKK-TOA LHC-7D Electrode Holder with Lift Up Type Jet Cleaner LHC-7D A detector which can lift up from the sample water and remove fouling from the pH/ORP electrode effectively. Automatic cleaning system that applies alternate streams of wash water and chemical solution (such as a 5% hydrochloric acid solution) to clean the pH/ORP detector. Immersion Type pH/ORP Detector with Some Cleaners
DKK-TOA UHC-7C / UHC-8C Flow-Through Type Detector with Ultrasonic Cleaner UHC-7C / UHC-8C Detectors composed of holder and ultrasonic cleaner: Immersion type (UHC-7C) and flow-through type (UHC-8C) One-touch detachable holder enables quick calibration and easy maintenance Compatible with GSS series Immersion Type pH/ORP Detector with Some Cleaners
DKK-TOA JHC-7C/JHC-8C Immersion Type Detector with Water Jet Cleaner JHC-7C/JHC-8C Detectors composed of holder and water-jet cleaner: Immersion type(JHC-7C) and flow-through type(JHC-8C)  By spraying water onto the tip of electrode, the water pressure washes fouling away  One-touch detachable holder and easy maintenance Simple installation with a sensor, timer&electromagnetic valve integrated unit Immersion Type pH/ORP Detector with Some Cleaners
DKK-TOA BHC-7C Immersion Type pH/ORP Detector with Brush Cleaner BHC-7C Immersion type pH/ORP electrode holder with cleaning brush (BHC-7C) The swing movements wash the electrode tip and prevent it from fouling  One-touch detachable holder and easy maintenance Immersion Type pH/ORP Detector with Some Cleaners
DKK-TOA RHC-7C / RHC-7EC Immersion Type Detector with Chemical Cleaner RHC-7C / RHC-7EC Immersion type electrode holder combined with chemical cleaning system By spraying mixed air&cleaning agents onto the electrode tip it dissolves fouling away  Immersion Type pH/ORP Detector with Some Cleaners
DKK-TOA MAC-355 pH Meter with Auto Calibration MAC-355 Automatic cleaning and 2-point calibration functions serve long-term reliable pH measurement with just little maintenance Lift-up type design incorporated with air jet cleaning allows for superior cleaning effect and stable measurement  Self-diagnosis and useful message display  Meas. range pH: -1 - 15 pH Meter with Auto-Calibration/Chemical Cleaner
DKK-TOA PAC‐R7 pH Meter with Chemical Cleaner PAC‐R7 Easy installation as equipments are previously set on the hold stand Designed for long-term, continuous and highly reliable pH measurement in wastewater treatment facilities  Including mounting brackets Meas. range  pH: -1 - 15 -5 - 100℃ pH Meter with Auto-Calibration/Chemical Cleaner
DKK-TOA SHBM-161 / 163 (2-wire) Compact diecast aluminum enclosure ExiallCT4 (combined with a Zener Barrier) explosion-proof and IP65 conformed enclosure Easy calibration done with standard solution  Auto-detection of electrodes deterioration Alterable output range Meas. range SHBM-161: pH; -1 - 15 SHBM-163: ORP; -2000 - +2000 mV Intrinsically Safe Explosion-Proof Type Transmitter for Industrial pH/ORP Analyzer
DKK-TOA ELP-005/006/007 ELP-045/046/047/048 Suitable for bio-process tanks (fermentation tanks). KCl non-refillable and leadless type. Steam sterilizable, strong glass membrane, lead-free safe design Two types available: Liquid junctions of both pressurized gel type products (ELP-005/006/007) and double junction type products (ELP-045/046/047/048) Various electrode lengths available according to various tank sizes Meas. range pH: 0 - 14 pH Sensor for Bio-Process Applications
DKK-TOA HM-30P / 31P Standard model for pH measurement (HM-30P) Sophisticated type, capable of pH and ORP measurements (HM-31P) Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins) Data storage up to 1000 points  Meas. range pH 0 - 14 (HM-30P/31P) 0 - 100.0 degrees C (HM-30P/31P) 0 - ±2000 mV (HM-31P) (ORP electrodes sold separately) Handheld pH/ORP Meter
DKK-TOA RM-30P Handheld ORP Meter RM-30P Dedicated model for ORP measurement Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins) Data storage up to 1000 points  Meas. range 0 - ±2000 mV 0 - 100.0 degrees C Handheld pH/ORP Meter
DKK-TOA WM-32EP 2-channel type, simultaneous measurement and display of pH/conductivity Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins) Data storage up to 1000 points PC and external printer connectable  Measurement items pH, ORP, conductivity, resistivity, salinity, temperature (ORP electrodes sold separately) Handheld Electrical Conductivity/pH Meter
DKK-TOA IM-32P 2-channel type, simultaneous measurement and display of pH/ions Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins) Data storage up to 1000 points PC and external printer connectable   Measurement items pH, ORP, ions, temperature (ORP and ion electrodes sold separately) Handheld Ion/pH Meter
DKK-TOA DM-32P 2-channel type, simultaneous measurement and display of DO/pH Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins) Data storage up to 1000 points PC and external printer connectable  Measurement items  pH, ORP, DO, temperature (ORP electrodes sold separately) Handheld DO/pH Meter
DKK-TOA CM-31P(for standard use) / CM-31P-W(for pure water) Display of salinity (NaCl) is available (CM-31P) Highly accurate measurement in pure water attainable with the pure water temperature compensation function (CM-31P-W) Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins)  Meas. range (when using a standard cell) 0.1 mS/m - 10 S/m 0.1 Ω·m - 10k Ω·m Salinity: 0 - 4.00% 0 - 80℃ Handheld Electrical Conductivity Meter