CT-800
|
|
Solid core current switch, monitors 1-250Amps, sensor trips at 1Amp. Switch can be used for both AC and DC circuits. |
Current Switches/Transducers
|
|
|
CT-805
|
|
Split Core current switch, monitors 1.5-250Amps, sensor trips at 1.5Amps. Switch can be used for both AC and DC circuits. |
Current Switches/Transducers
|
|
|
CT-815
|
|
Split core current switch, monitors 1.5-150Amps. Adjustable set point and status LED's. |
Current Switches/Transducers
|
|
|
CT-H10F
|
|
Split core current switch, monitors 3.5-100Amps, adjustable set point between 3.5-100Amps, auto calibration, and status LED's. |
Current Switches/Transducers
|
|
|
CT-H600
|
|
Split core current relay switch, monitors 0.15 to 200Amps, fixed setpoints at 0.15Amps max, no status LED's. |
Current Switches/Transducers
|
|
|
CT-H608
|
|
Split core current relay switch, monitors 1.25-50Amps, adjustable set point between 1.25-50Amps, status LED's. |
Current Switches/Transducers
|
|
|
HiTemp140-TS
|
|
Thermal shield for the HiTemp140 data logger. Available with a vented top or flush top. The HiTemp140-TS is a thermal shield designed for use with the HiTemp140 data logger. This durable enclosure allows the data logger to be used in temperatures from –200°C to +250°C, making it ideal for peanut roasting, food processing, autoclave validation and other extreme temperature applications. To use, simply place the HiTemp140 in the IFC400 docking station (sold separately). Use the MadgeTech... |
Enclosures
|
|
|
HiTemp150-TS
|
|
The HiTemp150-TS is a thermal shield enclosure for use with the HiTemp150 and HiTemp150-PT data loggers. This durable enclosure can withstand temperature up to 250°C. The device is easy to use. Simply open the enclosure, insert the HiTemp150 or HiTemp150-PT, thread the probe through the end cap and latch it back onto the barrier body. The HiTemp150-TS is built for use in applications that require extreme temperature monitoring, such as peanut roasting and food processing. |
Enclosures
|
|
|
ThermoVault1000
|
|
The ThermoVault1000 is a stainless steel thermal barrier for use with the Temp1000P or Temp1000FP data loggers. This durable enclosure is submersible and can withstand temperatures of up to 350°C (230°C with O-Ring). This device is easy to install. Simply open the enclosure, insert the data logger, thread the probe through the end cap and latch it back onto the barrier body. The ThermoVault1000 is built for use in applications that require extreme temperature monitoring, such as with... |
Enclosures
|
|
|
ThermoVault140
|
|
The ThermoVault140 is an extreme high temperature data logging system, for use with a HiTemp140 data logger and stainless steel thermal barrier enclosure. This durable system can withstand temperatures up to 250°C when completely submerged and 350°C in dry heat applications (O-ring removed).
The ThermoVault140 is built for use in harsh applications that require extreme temperature monitoring, such as with furnace profiling, geothermal down-hole recording, and oven data logging.
The... |
Enclosures
|
|
|
Waterbox101A
|
|
The WaterBox101A is a weatherproof enclosure designed for use with MadgeTech’s 101A series data loggers. The enclosure provides a water tight seal, allowing non-water resistant data loggers to be used in wet environments. The WaterBox101A is machined out of black anodized aluminum, and has four oval mounting holes for easy surface attachment. The enclosure features a water-tight communication access plug with chain attachment, stainless steel probe outlet and a clear plastic cover. To use,... |
Enclosures
|
|
|
Waterbox110C
|
|
The Waterbox110C is a water resistant enclosure designed for use with the 110 series data loggers. This enclosure provides a water tight seal, allowing non-water resistant data loggers to be used in wet environments. The Waterbox110C is machined out of black anodized aluminum, and is wall mountable. The enclosure features a water-tight communication access plug and cable gland outlet. To use, simply unscrew the 4 hex screws and insert the data logger. Loosen the compression fitting and... |
Enclosures
|
|
|
24 Gauge Teflon Insulated Thermocouple
|
|
24 gauge, teflon insulated, thermocouple with mini plug and welded tip. Available in type J, K, T, and E, with a 36" or 72" cable. |
Probes
|
|
|
304 SS 3/16" dia. Thermocouple Probe
|
|
304 SS 3/16" dia. Available in types J, K and T with a 6" or 12" sheath.
Temperature range for sheath: 900°C
Temperature range for lead wire: 260°C |
Probes
|
|
|
EC-5
|
|
Soil moisture probe, 0~100% VMC, 2.1" length with 16' cable |
Probes
|
|
|
Glycol Bottle with Thermocouple Probe Assembly
|
|
30ml, 60ml and 250ml Glycol Bottles with Thermocouple Probe Assembly |
Probes
|
|
|
HP-1
|
|
The HP-1 is an oven hotplate thermocouple that is designed for monitoring and recording the temperature of stove top griddles, burners and other flat surfaces. It can measure temperatures up to 390°F (200°C) and may be used with electric stoves. To use, simply connect the HP-1 to a thermocouple based temperature data logger, such as the TC101A or TCTemp2000, then start the logger. Place the HP-1 directly on the flat surface, and position the data logger a safe distance away from the heat... |
Probes
|
|
|
pH-Rugged Electrode
|
|
The pH-RUGGED ELECTRODE is a submersible CPVC pH electrode that is suited for use in outdoor applications such as monitoring drums, tanks or streams. The electrode has a quick latch mechanism which allows it to be inserted into a BNC connector by simply rotating it a quarter turn. For use with the MadgeTech pH loggers, a cable assembly and an RTD temperature reference is required.
Two mounting assembly options are available. The pH RUGGED ATC CABLE mounting assembly connects directly to the... |
Probes
|
|
|
pH1
|
|
General Purpose pH probe for use with the pHTemp101. Features standard BNC connector. Clear, epoxy-bodied, gel-filled combination electrode measures the entire 0 to 14pH range. Soaker storage bottle included. |
Probes
|
|
|
RFOT-HDA
|
|
The RFOT-HDA is a probe attachment for the RFOT data logger. The device is built for use with hot dogs, sausages, and other small meat products.
To use, simply slide the RFOT-HDA over the RFOT probe, then mount in place using two set screws. Next, insert a meat product through the o-ring onto the probe. The RFOT-HDA will guide the product into place, ensuring that the probe is inserted into the center of the product. Internal temperature can then be logged and analyzed using the RFOT data... |
Probes
|
|