Kyoritsu 5010 (for Current) / 5020 (for Current & Voltage)
|
|
3 channel inputs for the simultaneous recording of Leakage Current, Load Current and Voltage
•
Power Quality analysis(only on KEW 5020)(Power Quality:Reference voltage, Swell, Dip, Short power Interruptions)
Large Capacity for storing 60,000 data points
60,000 data points can be recorded when 1ch is used, and when all the three channels are used, 20,000 data points per channel can be recorded
Lowpass Filter will filter out the... |
Logger
|
|
|
Kyoritsu 5001
|
|
THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT60,000 DATA IS RECORDED
60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel
Continuous measurement time
About 40 days
Data where it doesn’t disappear even if battery is consumed
Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged.... |
Logger
|
|
|
Kyoritsu 8309
|
|
Floating voltage can be measured
*Floating voltage:phase to phase voltage not grounded
*KEW 5020-01:KEW 5020 logger with KEW 8309 (1 pce.)
For use with following model
5020
|
Voltage Sensor
|
|
|
Kyoritsu 8130
|
|
Can measure AC current up to 1000A
•
Flexible and light weight by the air core coil used at the sensor part
•
Designed to meet the international safety standardIEC 61010-1 CAT IV 300V, CAT III 600V
Applicable model
5010/5020 (*), 6300, 6305, 6310, 6315
|
Flexible Clamp Sensor
|
|
|
Kyoritsu 8129
|
|
Flexible for various test fields
•
Can measure AC current up to 3000A
•
Flexible and light weight by the air core coil used at the sensor part
•
Measurable conductor size:max Φ150mm
•
Designed to meet the international safety standardIEC 61010-1 CAT.III 600V
Applicable model
5010/5020 (*), 6300, 6305, 6310, 6315
|
Flexible Clamp Sensor
|
|
|
Kyoritsu 8121
|
|
Applicable model 5010/5020
Conductor size
Φ24
Rated current
AC 100A
Output voltage
AC 500mV/100A (AC 5mV/A)
Accuracy
|±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage
AC 3540V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~40ºC, less than 85% RH (without condensation)
Output impedance
Approx. 9.5Ω
Applicable standards
IEC 61010-1:2001,IEC... |
Load current clamp sensors
|
|
|
Kyoritsu 8122
|
|
Applicable model 5010/5020
Conductor size
Φ40
Rated current
AC 500A
Output voltage
AC 500mV/500A (AC 1mV/A)
Accuracy
|±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage
AC 5350V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~40ºC, less than 85% RH (without condensation)
Output impedance
Approx. 1.9Ω
Applicable standards
IEC 61010-1:2001,IEC... |
Load current clamp sensors
|
|
|
Kyoritsu 8123
|
|
Applicable model 5010/5020
Conductor size
Φ55
Rated current
AC 1000A
Output voltage
AC 500mV/1000A (AC 0.5mV/A)
Accuracy
|±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage
AC 5350V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~40ºC, less than 85% RH (without condensation)
Output impedance
Approx. 1.5Ω
Applicable standards
IEC 61010-1:2001,IEC... |
Load current clamp sensors
|
|
|
Kyoritsu 8146
|
|
Applicable model
5010/5020, 6310, 6315
* Cannot be used for power measurement.
Conductor size
Φ24
Rated current
AC 30A
Output voltage
AC 1500mV/30A (AC 50mV/A)
Accuracy
0~15A|±1.0%rdg±0.1mV (50/60Hz)|±2.0%rdg±0.2mV (40Hz~1kHz)
15~30A|±5.0%rdg (50/60Hz)|±10.0%rdg (45Hz~1kHz)
Withstand voltage
AC 3540V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~50ºC, less than... |
Leakage & Load current clamp sensors
|
|
|
Kyoritsu 8147
|
|
Applicable model
5010/5020, 6310, 6315
* Cannot be used for power measurement.
|
Leakage & Load current clamp sensors
|
|
|
Kyoritsu 8148
|
|
Applicable model
5010/5020, 6310, 6315
* Cannot be used for power measurement.
|
Leakage & Load current clamp sensors
|
|
|
Kyoritsu 8141
|
|
Applicable model
5000/5001, 5010/5020, 6310
* Cannot be used for power measurement.
|
Leakage current clamp sensors
|
|
|
Kyoritsu 8142
|
|
Applicable model
5000/5001, 5010/5020, 6310
* Cannot be used for power measurement.
|
Leakage current clamp sensors
|
|
|
Kyoritsu 8143
|
|
Applicable model
5000/5001, 5010/5020, 6310
* Cannot be used for power measurement.
|