Hioki Clamp on Sensor 9661
|
|
500A Voltage Output Sensor for Current Load Measurements
Hioki current sensors are best-in-class devices for use with power meters, PQAs and Memory HiCorders. The 9661 is a 500A AC voltage output clamp sensor for measuring large load current.
Note: Supports power quality analyzers, power meters and other data acquisition equipment with voltage input |
High Frequency Sensors | CTs | Current Probes
|
|
|
Hioki Clamp onLeak Sensor 9675
|
|
10A Voltage Output Sensor for Leak Current Measurements
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9675 is a 10A AC voltage output clamp sensor for measuring leak current. The high-permeability magnetic material of the sensor’s core and magnetic shield enables high-precision measurement of very weak currents.
Note: Supports power quality analyzers with voltage input |
High Frequency Sensors | CTs | Current Probes
|
|
|
Hioki Clamp on Leak Sensor 9657-10
|
|
10A Voltage Output Sensor for Leak Current Measurements
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9657-10 is a 10A AC voltage output clamp sensor for measuring leak current. The high-permeability magnetic material of the sensor’s core and magnetic shield enables high-precision measurement of very weak currents.
Note: Supports power quality analyzers with voltage input |
High Frequency Sensors | CTs | Current Probes
|
|
|
Hioki Clamp on Probe 9132-50
|
|
Multi-range 1000A Voltage Output Sensor for Capturing Waveforms with DMMS, Memory HiCorders and other data acquisition equipment
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9132-50 is multi-range 1000A AC voltage output clamp sensors for capturing waveforms with DMMs and Memory HiCorders.
For 50/60Hz commercial power lines; no external power supply required. |
High Frequency Sensors | CTs | Current Probes
|
|
|
Hioki Clamp on Probe 9010-50
|
|
Multi-range 500A Voltage Output Sensor for Capturing Waveforms with DMMS
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9010-50 is multi-range 500A AC voltage output clamp sensors for capturing waveforms with DMMs
For 50/60Hz commercial power lines; no external power supply required. |
High Frequency Sensors | CTs | Current Probes
|
|
|
Hioki Clamp on Probe 9018-50
|
|
Multi-range 500A Voltage Output Sensor for Capturing Waveforms with DMMS, Memory HiCorders and other data acquisition equipment.
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9018-50 is a multi-range 500A AC voltage output clamp sensor with superior phase characteristics for capturing waveforms with DMMs and Memory HiCorders.
For 50/60Hz commercial power lines; no external power supply required. |
High Frequency Sensors | CTs | Current Probes
|
|
|
Hioki Clamp on Sensor 9668
|
|
1000A Current Output Sensor for Measuring Load Current with Models 8205-10 and 8206-10 Micro HiLoggers
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9669 is a 1000A AC current output clamp sensor for measuring load current and commercial power lines with the 8205-10 and 8206-10 Micro HiLoggers.
Note: Compatible only with the 8205-10 and 8206-10 Micro HiLoggers; not compatible with the discontinued 8205 and 8206 or data loggers. |
High Frequency Sensors | CTs | Current Probes
|
|
|
Hioki Clamp on Sensor 9650
|
|
100A Current Output Sensor for Measuring Load Current with Models 8205-10 and 8206-10 Micro HiLoggers
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9650 is a 100A AC current output clamp sensors for measuring load current and commercial power lines with the 8205-10 and 8206-10 Micro HiLoggers.
Note: Compatible only with the 8205-10 and 8206-10 Micro HiLoggers and Clamp Logger 3636-20 |
High Frequency Sensors | CTs | Current Probes
|
|
|
Hioki Clamp on Sensor 9651
|
|
500A Current Output Sensor for Measuring Load Current with Models 8205-10 and 8206-10 Micro HiLoggers
Hioki current sensors are best-in-class devices for accurately capturing a wide range of current levels. The 9651 is a 500A AC current output clamp sensors for measuring load current and commercial power lines with the 8205-10 and 8206-10 Micro HiLoggers.
Note: Compatible only with the Micro HiLoggers 8205-10 and 8206-10 and Clamp Logger 3636-20 |