Fluke 113 Utility Multimeter

Category: Electrical Testers
The Fluke 113 True-rms utility multimeter designed for basic electrical tests, has the features needed to check and test for most electrical problems. This is simple-to-use and has significant improvements over its predecessor, the Fluke 7-600.

Designed for the utility user, this new meter has the features needed to repair most electrical problems encountered by utility workers and linemen everyday. With features such as Fluke’s VCHEK, Added measurement functions, and conformance to the latest safety standards, the Fluke 113 has a much larger display that’s easier to view, making this new meter a must have for the utility users’ toolbox.
 
Fluke 113 Specifications
Function Range Resolution Accuracy
Current Type: Volts
Volts
Measurement 6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
DC, 45 to 500 Hz: 2.0% + 3
500 Hz to 1 kHz: 4.0% + 3
Input Impedance
(Nominal)
~3kW<300 pF
Common Mode Rejection Ratio
(1 kΩ Unbalanced)
60 dB at DC,
50 or 60 Hz
Current Type: Diodes
Diodes
Measurement Range Resolution Accuracy
 2.000 V  0.001 V  2.0% + 3
Open Circuit
Test Voltage
 < 2.7 V DC
Full Scale Voltage  < 0.7 V DC
Short Circuit Current  < 350 µA
Current Type: Sound based
Sound
Measurement Range Resolution Accuracy
- -  Beeper on < 20 Ω, off > 250 Ω;
 Detects open or shorts of 500 µs or longer
Current Type: OHMs
OHMs
Measurement Range Resolution Accuracy
 600.0 Ω
 6.000 kΩ
 60.00 kΩ
 0.1Ω
 0.01 kΩ
 0.001 kΩ
 0.9% + 2
 0.9% + 1
 0.9% + 1
Open Circuit
Test Voltage
 < 2.7 V DC
Full Scale Voltage  2.000 V DC
Short Circuit Current  < 1.0 mA
Current Type: Capacitors
Capacitors
Measurement Range Resolution Accuracy
 1000 nF
 10.00 µF
 100.0 µF
 9999 µF
 1 nF
 0.01 µF
 0.1 µF
 1 µF
 1.9% + 2
 1.9% + 2
 1.9% + 2
 100 µF - 1000 µF: 1.9% + 2; >1000 µF: 5% + 20
Additional note for all functions:
  • All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together
  • Crest factor of ≤3 at 4000 counts, decreasing linearly to 1.5 at full scale
  • After measuring voltage, a wait time of 1 minute is required to maintain accuracy, ohms, capacitance, diode test, and continuity
Specifications Details
Accuracy 0.5%
Features True RMS Yes
Capacitance Yes
Display Backlight Yes
MIN/MAX/AVG Yes
Probe Holders Yes
Maximum Voltage between any
terminal and earth ground
600B
Temperature coefficient 0.1 x (specified accuracy)/°C (< 18°C or > 28°C)
Temperature Operating -10°C to 50°C (14°F to 122°F)
Storage -40°C to 60°C (-22°F to 140°F)
Altitude Operating 2,000 m
Storage 10,000 m
Relative Humidity 95% at 30°C
75% at 40°C
45% at 50°C
Shock 1 Meter drop per IEC 61010-1-2001
Vibration Per MIL-PRF-28800 for Class 2 instrument
Safety Complies with ANSI/ISA 82.02.01 (61010-1), 2004, CAN/CCSA-C22.2 No.  61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd edition for measurement Category III, 600 V, Pollution degree 2, EMC EN61326-1
EMI Regulation Complies with FCC Part 15, class B
Display 3 3/4-digits, 6000 counts, updates 4/sec
Battery Type 9 Volt Alkaline, ANSU 1604A/IEC 6F22
Cover Type Battery Door (for quick battery changes)
Life 300 hour typical, without Backlight
Physical Dimensions Size 6.58" x 3.35" x 1.81" inches (167.1mm x 85.1mm x 46mm)
Weight 404 grams (13.0 oz)
Ask about this product